EFEK GAYA ANTAR PARTIKEL DAN DIAMETER PARTIKEL TERHADAP KECEPATAN MINIMUM FLUIDISASI

Febijanto, Irhan (Unknown)



Article Info

Publish Date
15 Dec 2009

Abstract

In this study, the effect of diameter particle and the effect of inter-particlecohesion force due to liquid bridge formation on the minimum fluidization velocityin the fluidized bed have investigated. Also the effect of inter-particle cohesionforce on a fluidization condition of the bed has observed by video camera. Theinvestigation results showed bigger diameter can give higher minimumfluidization velocity, and stronger inter-particle force can give higher minimumfluidization velocity, and then make a quality of fluidization of bed lower. Usingwith this investigation results, the mechanism of fouling and slaggingphenomena, which are happen in the coal-fired boiler can be explained.Kata kunci: fluidized bed, minimum fluidization velocity, particle diameter,relative humidity, inter-particle cohesion force

Copyrights © 2009






Journal Info

Abbrev

Enerlink

Publisher

Subject

Energy

Description

Enerlink adalah jurnal yang diterbitkan 2 kali setahun oleh Pusat Teknologi Pengembangan Sumberdaya Energi dan Industri Kimia BPPT di bidang energi dan lingkungan. Enerlink is a scientific journal that publishes twice annually by Centre of Energy Technology and Chemical Industry of ...