cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota padang,
Sumatera barat
INDONESIA
Jurnal Dampak
Published by Universitas Andalas
ISSN : 25975129     EISSN : 18296084     DOI : -
Core Subject : Social, Engineering,
Jurnal Dampak merupakan publikasi bidang lingkungan hidup yang bersifat ilmiah, dapat berupa hasil penelitian, aplikasi teknologi tepat guna atau ide penyelesaian terhadap permasalahan lingkungan hidup yang ada. Naskah belum pernah dipublikasikan dalam media lain, atau naskah sedang dalam proses review dan/atau menunggu untuk diterbitkan di media lain.
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 19, No 1 (2022)" : 6 Documents clear
KUALITAS AIR BAKU UNTUK DEPOT AIR MINUM AIR ISI ULANG (STUDI KASUS DI DEPOT AIR MINUM ISI ULANG ANGKE TAMBORA) Rizqa Puspitarini; Riva Ismawati
Dampak Vol 19, No 1 (2022)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.19.1.1-7.2022

Abstract

Water for consumption purposes must be standardized, in terms of quality, physical, chemical and biological parameters, therefore will not cause side effects to health. Water quality standards indicate the recommended and permitted concentration value for all parameters. This research aims to examine the quality of water sourced from the Salak mountain springs. The location of clean water sampling was carried out on Ciapus Mount Salak raw water. Water quality test results from physical parameters of clean water including turbidity, color, total dissolved solid, temperature and odor have. Chemical parameters int the clean water standard are pH, iron, fluoride, hardness, Manganese, Nitrate, nitrite, cyanide, mercury, arsenic, cadmium, chromium, selenium, zinc, sulfate, lead and organic. Biological parameters of clean water including MPN coliform and Escherichia coli have standardized quality standards. Based on research results that all parameter of clean water including physical, chemical and biological have standardized quality can used to treatment drinking water.Keywords: clean water, drinking water, water quality standard, chemical parameter, biological parameterABSTRAKAir yang dikonsumsi harus memenuhi standar kualitas fisika, kimia dan biologi agar tidak menimbulkan efek samping bagi kesehatan. Baku mutu kualitas air mengidikasikan batas kadar tertinggi yang disarankan untuk semua parameter. Penelitian ini bertujuan menguji kualitas air yang bersumber dari mata air Gunung Salak. Parameter uji kualitas air fisika meliputi kekeruhan, warna, padatan terlarut, suhu dan bau. Parameter uji kualitas air kimia meliputi pH, besi, fluorida, kesadahan, mangan, nitrat, nitrit, sianida, merkuri, arsen, kadmium, khromium, selenium, seng, sulfat, timbal dan zat organik. Parameter uji kualitas air fisika meliputi MPN coliform and Escherichia coli. Berdasarkan hasil penelitian menunjukkan bahwa semua parameter kualitas air bersih yang meliputi fisika, kimia dan biologi memenuhi baku mutu yang dapat digunakan bahan baku pengolahan air minum.Kata Kunci: air bersih, air minum, standar kualitas air, pamateter kimia, parameter fisika
Analisis Hubungan Jumlah Kendaraan Dan Konsentrasi Karbon Monoksida (CO) Di Kota Gorontalo, Provinsi Gorontalo Indri Hamzah; Fitryane Lihawa; Sri maryati
Dampak Vol 19, No 1 (2022)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.19.1.40-49.2022

Abstract

The major source of air pollution in Indonesia comes from the transportation sector, particularly from motor vehicle emission pollution. One of the pollutants is carbon monoxide (CO) gas, which is highly hazardous if surpassing the ambient air quality standard. Gorontalo City is a place with a yearly increase of number of motor vehicles. Meanwhile, motorcycle contributes to 72,42% of affecting air quality. The research objective was to analyze the relationship of CO concentration and number of vehicles in Gorontalo City. This study included correlational research type discussing the number of motor vehicles and concentration of CO in Gorontalo City. The research samples were retrieved 3 times a week, on Monday, Friday, and Sunday in location with high, medium, and no vegetation in the roadside. The calculation of number of motor vehicles was carried out with the assistance of traffic survey from, while the measurement of CO concentration was done by using impinger. The research finding showed that the highest number of vehicles was on Prof. H.B Jassin Street, and the lowest was on Manggis Street. The highest concentration of CO was on Jend. Sudirman street and the lowest was on Mayor Dullah Street. The relation of number of motor vehicles and concentration of CO had value of interpretation of r= 0,416 with regression equation of y= 0,0271x + 104,17. The result indicated a positive relation pattern. The determinant factor was vegetation factor in the roadside, weather, and research time. Keywords: Number of Motor Vehicle, Concentration of Carbon Monoxide (CO), Gorontalo City ABSTRAKSumber utama pencemaran udara di Indonesia berasal dari sektor transportasi, khususnya dari pencemaran emisi kendaraan bermotor. Salah satu pencemar tersebut adalah gas karbon monoksida (CO) yang sangat berbahaya jika melebihi baku mutu udara ambien. Kota Gorontalo merupakan kota dengan peningkatan jumlah kendaraan bermotor dari tahun ke tahun. Sedangkan sepeda motor memberikan kontribusi 72,42% terhadap kualitas udara. Tujuan penelitian adalah menganalisis hubungan konsentrasi CO dengan jumlah kendaraan di Kota Gorontalo. Penelitian ini termasuk jenis penelitian korelasional yang membahas tentang jumlah kendaraan bermotor dan konsentrasi CO di Kota Gorontalo. Pengambilan sampel penelitian dilakukan 3 kali dalam seminggu, yaitu pada hari Senin, Jumat, dan Minggu di lokasi dengan tinggi, sedang, dan tidak ada vegetasi di pinggir jalan. Perhitungan jumlah kendaraan bermotor dilakukan dengan bantuan survey lalu lintas, sedangkan pengukuran konsentrasi CO dilakukan dengan menggunakan impinger. Hasil penelitian menunjukkan bahwa jumlah kendaraan terbanyak berada di Jalan Prof. H.B Jassin dan terendah di Jalan Manggis. Konsentrasi CO tertinggi terdapat pada Jend. Jalan Sudirman dan terendah berada di Jalan Walikota Dullah. Hubungan jumlah kendaraan bermotor dan konsentrasi CO memiliki nilai interpretasi r= 0,416 dengan persamaan regresi y= 0,0271x + 104,17. Hasilnya menunjukkan pola hubungan yang positif. Faktor penentunya adalah faktor vegetasi tepi jalan, cuaca, dan waktu penelitian. 
Pengolahan Limbah Cair Laundry Menggunakan Kombinasi Media Pasir Silika-Karbon Aktif-Manganese Greensand Septi Fatimatus Zahro; Rr. Diah Nugraheni Setyowati; Sulistiya Nengse; Teguh Taruna Utama
Dampak Vol 19, No 1 (2022)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.19.1.8-16.2022

Abstract

Laundry wastewater contains various kinds of contaminants, and high BOD5, COD, and phosphate. The wastewater laundry is directly disposed into sewerage without treatment. The results showed that BOD5, COD, TSS, phosphate, and pH parameters of laundry wastewater are 180.7 mg/L, 500.3 mg/L, 30 mg/L, 31.8 mg/L, and 8.3, respectively. One of the wastewater treatment methods is filtration. This research used multimedia filtration with three different media. There are three kinds of media which are silica sand, activated carbon, and manganese greensand. The purpose of this research was to find out the design of the reactor, to know the concentration of the test parameter before and after this processing, and to calculate the removal efficiency. The results showed that the reactor design measured 15x15x80 cm. On water quality before processing, there are three parameters that do not meet quality standards, and after processing all of the parameter tests do meet quality standards except phosphate. The best penyisihan efficiency for BOD5 test parameters was 68.56%, COD was 65.78%, TSS was 6.67%, phosphate was 16.35%, and pH was 12.04%. Further research is needed to know the saturation time of each filter media. Keywords: Laundry wastewater, filtration, silica sand, activated carbon, manganese greensand        ABSTRAKAir limbah laundry mengandung berbagai macam kontaminan, dan BOD5, COD, dan fosfat yang tinggi. Air limbah cucian ini langsung dibuang ke saluran pembuangan tanpa pengolahan. Hasil pengecekan parameter BOD5, COD, TSS, fosfat, dan pH air limbah laundry adalah 180,7 mg/L, 500,3 mg/L, 30 mg/L, 31,8 mg/L, dan 8,3. Salah satu metode pengolahan air limbah adalah dengan penyaringan. Dalam penelitian ini digunakan filtrasi multimedia dengan tiga media yang berbeda. Ada tiga macam media yaitu pasir silika, karbon aktif, dan manganese greensand. Tujuan dari penelitian ini adalah untuk mengetahui desain reaktor, mengetahui konsentrasi parameter uji sebelum dan sesudah pengolahan, serta menghitung efisiensi penyisihan. Hasil penelitian menunjukkan bahwa desain reaktor berukuran 15x15x80 cm. Pada kualitas air sebelum pengolahan ada tiga parameter yang tidak memenuhi baku mutu, dan setelah pengolahan semua parameter uji memenuhi baku mutu kecuali fosfat. Efisiensi penyisihan terbaik untuk parameter uji BOD5 adalah 68,56%, COD 65,78%, TSS 6,67%, fosfat 16,35%, dan pH 12,04%. Perlu dilakukan penelitian lebih lanjut untuk mengetahui waktu saturasi masing-masing media filter. Kata kunci: Air limbah laundry, filtrasi, pasir silika, karbon aktif, manganese greensand 
Identifikasi Pencemaran Limbah Di Sekitar TPA Antang Makassar Menggunakan Metode Geolistrik Resistivitas Abdul Mun’im; Sappewali Sappewali; Ayusari Wahyuni
Dampak Vol 19, No 1 (2022)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.19.1.17-21.2022

Abstract

The data presented in this paper are related to the characterization of a subsurface layer of TPA Antang, Makassar, South Sulawesi. The method used in this study is geo-electrical resistivity Wenner configuration by taking the data 3 lines in each region with lengths 150 m. Data processing used non-linear least square optimization with that of the 2D inversion software Res2Dinv. The results showed that the area was underlain by two layers of lithologic sections. The first layer with a resistivity value of 11.5 - 33.64 Ωm with a thickness ranging from 2-6 meters below the surface (original ground surface), was the sediment resulting from stockpiling dominated by silty sand sediment to sand based on field observation information. The second layer with a resistivity value of 3.02 - 11.5 Ωm with a depth ranging from 2 - 6 meters from the surface. The determination of this layer is based on information on well data and responses which indicate that this layer is swampy sediment, dominant sand ranging from sand alone to silty sand. The very small value of recessivity indicates that this layer is not compact sediment so the pore space between the grains was saturated. This layer is identified as a shallow aquifer. Based on the resistivity value, the fluid that filled this layer was divided into two types of fluids, fluids with a low resistivity value of 3.02 - 5.71 Ωm, it is assumed that the influence of leachate which is electrolytic makes it easy to flow electric current, and fluid with a resistivity value of 5.71 - 11.5 Ωm is a fluid that has not been contaminated with leachate. Keywords: Antang Landfill, geoelectric, groundwater, resistivity, waste ABSTRAKData yang disajikan dalam makalah ini terkait dengan karakterisasi lapisan bawah permukaan TPA Antang, Makassar, Sulawesi Selatan. Metode yang digunakan dalam penelitian ini adalah metode geolistrik resistivitas konfigurasi Wenner dengan mengambil data 3 jalur masing-masing daerah dengan panjang 150 m. Pemrosesan data menggunakan optimasi kuadrat terkecil non-linier dengan perangkat lunak inversi 2D Res2Dinv. Hasil penelitian menunjukkan bahwa daerah tersebut dilatarbelakangi oleh dua lapisan bagian litologi. Lapisan pertama dengan nilai resistivitas 11,5 - 33,64 m dengan ketebalan berkisar antara 2-6 meter di bawah permukaan (original ground surface), merupakan sedimen hasil penimbunan yang didominasi oleh sedimen pasir berlumpur hingga pasir berdasarkan informasi observasi lapangan. Lapisan kedua dengan nilai resistivitas 3,02 – 11,5 m dengan kedalaman berkisar antara 2 – 6 meter dari permukaan. Penentuan lapisan ini berdasarkan informasi data sumur dan respon yang menunjukkan bahwa lapisan ini merupakan sedimen berawa, dominan pasir mulai dari pasir saja sampai pasir berlumpur (silty sand). Nilai resesivitas yang sangat kecil menunjukkan lapisan ini merupakan sedimen yang tidak kompak sehingga ruang pori antar butir jenuh oleh air. Lapisan ini diidentifikasi sebagai akuifer dangkal. Berdasarkan nilai resistivitasnya, fluida yang mengisi lapisan ini terbagi menjadi dua jenis fluida yaitu fluida dengan nilai resistivitas rendah 3,02 – 5,71 m, diduga pengaruh lindi yang bersifat elektrolitik memudahkan aliran arus listrik dan fluida dengan nilai resistivitas 5,71 – 11,5 m merupakan fluida yang belum tercemar lindi. Kata kunci: TPA Antang, geolistrik, air tanah, resistivity, limbah
Pengaruh Penggunaan Lahan Terhadap Debit Banjir Rancangan Di DAS Baubau Muhammad Nuzul; Mahmud Achmad
Dampak Vol 19, No 1 (2022)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.19.1.22-29.2022

Abstract

ABSTRACTThis research was conducted in the city of Baubau, Southeast Sulawesi Province, the location is focused on the area directly adjacent to the Baubau River which has a river length of 15,704 Km in the Baubau catchment with an area of 76,117 Km2. which empties into residential areas as areas where seasonal floods often occur. To reduce the risk of loss due to the impact of flooding flood control efforts are needed that can be carried out properly if the flood discharge design of the repeat design can be known. This study aims to analyze changes in land use against runoff coefficient with flood discharge design period of time in Baubau watershed. The analysis used is the descriptive analysis regarding the spatial distribution pattern of land use and its effect on the runoff coefficient in 2019. Then to get the discharge plan for the return time analysis was carried out using the Nakayasu Empirical method or the Synthetic Unit Hydrograph (HSS) with rainfall data for 2010 to 2019 obtained from the BMKG Betoambari station in Baubau City. From the results of the analysis, it will be obtained the flood discharge plans for the return period of 5, 10, 20, 25, 50, and 100 years.Keywords: Baubau watershed, flood discharge, hydrograph ABSTRAKPenelitian ini dilakukan di Kota Baubau Provinsi Sulawesi Tenggara, lokasi difokuskan pada wilayah yang berbatasan langsung dengan Sungai Baubau yang memiliki panjang sungai 15.704 Km di DAS Baubau dengan luas wilayah 76.117 Km2. yang bermuara di pemukiman penduduk sebagai daerah yang sering terjadi banjir musiman. Untuk mengurangi resiko kerugian akibat dampak banjir diperlukan upaya pengendalian banjir yang dapat dilakukan dengan baik jika debit banjir desain desain ulang dapat diketahui. Penelitian ini bertujuan untuk menganalisis perubahan penggunaan lahan terhadap koefisien limpasan dengan debit banjir periode rencana waktu di DAS Baubau. Analisis yang digunakan adalah analisis deskriptif mengenai pola sebaran spasial penggunaan lahan dan pengaruhnya terhadap koefisien limpasan Tahun 2019. Kemudian untuk mendapatkan debit rencana waktu ulang dilakukan analisis dengan menggunakan metode Empiris Nakayasu atau Hidrograf Satuan Sintetis (Synthetic Unit Hydrograph). HSS) dengan data curah hujan tahun 2010 sampai dengan tahun 2019 diperoleh dari stasiun BMKG Betoambari Kota Baubau. Dari hasil analisa tersebut akan diperoleh debit banjir rencana kala ulang 5, 10, 20, 25, 50 dan 100 tahun.Kata kunci: DAS Baubau, debit banjir, hidrograf
Analisis Hubungan Sumber Pencemaran Udara Dalam Rumah Terhadap Penyakit ISPA Pada Balita Tiya Mahelsa Putri; Febri Juita Anggraini; Zuli Rodhiyah
Dampak Vol 19, No 1 (2022)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.19.1.30-39.2022

Abstract

ARI is a disease with the highest mortality rate in the world, including in Indonesia. In Indonesia, ARI is still a public health problem due to high morbidity and mortality rates. As much as 15.4% of ARI cases attacked the under-five age group. In Jambi Province, ISPA is in the first rank of the ten main diseases from 2012-2019. This study aims to determine the relationship between sources of indoor air pollution and other risk factors that influence the occurrence of ARI in children under five. The method used in this research is cross-sectional. Test statistical analysis using the chi-square. Data collection was carried out by interviewing in the form of questionnaires and measuring using tools. The results showed that out of 108 children under five years old, 52 children had ISPA and 56 children had no ISPA. Based on the results of statistical tests, it shows that the variable smoking behavior, mosquito repellent, temperature, lighting, humidity, and parents' income have a relationship with the incidence of ARI in children under five years old, while the variables exclusive breastfeeding and immunization status statistically do not show a relationship with the incidence of ARI in children under five years old. Keywords: toddlers, acute respiratory infections (ARI), air pollution ABSTRAKISPA merupakan penyakit dengan angka kematian tertinggi di dunia, termasuk Indonesia. Di Indonesia, ISPA masih menjadi masalah kesehatan masyarakat karena tingginya angka kesakitan dan kematian. Sebanyak 15,4% kasus ISPA menyerang kelompok usia balita. Di Provinsi Jambi, ISPA menempati urutan pertama dari sepuluh penyakit utama dari tahun 2012-2019. Penelitian ini bertujuan untuk mengetahui hubungan antara sumber pencemaran udara dalam ruangan dengan faktor risiko lain yang mempengaruhi terjadinya ISPA pada balita. Metode yang digunakan dalam penelitian ini adalah cross sectional. Uji analisis statistik menggunakan chi-square. Pengumpulan data dilakukan dengan wawancara dalam bentuk angket dan pengukuran menggunakan alat bantu. Hasil penelitian menunjukkan bahwa dari 108 anak balita, 52 anak memiliki ISPA dan 56 anak tidak memiliki ISPA. Berdasarkan hasil uji statistik menunjukkan bahwa variabel perilaku merokok, pengusir nyamuk, suhu, pencahayaan, kelembaban, dan pendapatan orang tua memiliki hubungan dengan kejadian ISPA pada balita, sedangkan variabel pemberian ASI eksklusif dan status imunisasi secara statistik tidak menunjukkan hubungan dengan kejadian ISPA pada balita. Kata kunci: balita, infeksi saluran pernapasan akut (ISPA), pencemaran udara

Page 1 of 1 | Total Record : 6