Pendeteksi Hemoglobin Non Invasive Ningsih, Erika Wahyu; Fajrin, Hanifah Rahmi; Fitriyah, Aidatul
Medika Teknika : Jurnal Teknik Elektromedik Indonesia Vol 1, No 1 (2019): October
Publisher : Universitas Muhammadiyah Yogyakarta, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/mt.010102

Abstract

Anemia merupakan suatu kondisi medis dengan jumlah sel darah merah atau Hemoglobin (Hb) kurang dari 12 g/dL. Pemeriksaan hemoglobin (Hb) pada umumnya dilakukan dengan menggunakan metode invansive, akan tetapi metode ini terdapat beberapa kekurangan, diantaranya yaitu kurang efesien dan kurang ramah bagi para pasien yang mempunyai ketakutan terhadap jarum suntik. Penelitian ini bertujuan untuk membuat alat pendeteksi hemoglobin dalam darah dengan menggunakan metode non invasive dengan menggunkan infrared dan photodioda sebagai sensornya dan beberapa rangkaian elektronika lainnya sebagai pendukung. Dari hasil pengujian modul ini yang dibandingkan dengan EasyTouch GCHB, didapatkan simpangan maksimal yaitu 1 g/dl dan minimal 0,1 g/dl, dan mempunyai error maksimal sebesar 6,4 % dan minimal 0,8 % dan rata-rata error sebesar 0,1 % yang berarti alat ini layak untuk digunakan karena nilai simpangan maksimal adalah 1 g/dl dan toleransi dari hemoglobin adalah 1 g/dl.
UPAYA GURU PAI DALAM MENINGKATKAN RELIGIUSITAS PESERTA DIDIK Aslamiyah, Siti Suwaibatul; Fitriyah, Aidatul
Akademika Vol 12, No 02 (2018): Akademika
Publisher : Universitas Islam Lamongan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30736/adk.v12i02.179

Abstract

This study examines the efforts of PAI teachers in improving student religiosity. This study aims to determine the efforts of PAI teachers in improving student religiosity, supporting and inhibiting factors and giving solutions to overcome the inhibiting factors of PAI teachers in improving student religiosity. This study uses a qualitative research method through descriptive analysis. The results of the study could be concluded that there are some efforts made by PAI teachers in improving student religiosity including: providing guidance to all students to always worship and have morality, helping students with less religious knowledge, providing good examples for students, motivating students to actively perform worship and evaluate every activity. From the efforts made by PAI teachers, students coud be more diligent in conducting worship and having morality in accordance with the teachings of Islam. Supporting factors for teachers are internal factors, namely the teachers themselves; and external factors namely the existence of professional and qualified teachers who carry out their obligations properly, the existence of infrastructure supporting religious activities and the support from other teachers and all existing staff at school. Inhibiting factors for teachers include different student backgrounds and the environment or relationships that can affect students. The solution is to work with other teachers and students' parents so that they could supervise them.
Simulator Fetal Doppler Fajrin, Hanifah Rahmi; Maharani, Sari; Fitriyah, Aidatul
Medika Teknika : Jurnal Teknik Elektromedik Indonesia Vol 2, No 2 (2021): April
Publisher : Universitas Muhammadiyah Yogyakarta, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/mt.v2i2.11212

Abstract

Fetal Doppler adalah alat diagnostik yang digunakan untuk mendeteksi denyut jantung bayi yang berada dalam kandungan. Denyut jantung janin (DJJ) adalah sebuah indikator dalam sebuah pemeriksaan kandungan yang menandakan bahwa ada kehidupan di dalam kandungan seorang ibu, sehingga alat fetal doppler yang digunakan harus menampilkan Bit per menit (BPM) yang akurat agar tidak ada kesalahan dalam pemeriksaan janin. Oleh karena itu, harus dilakukan kalibrasi pada fetal doppler dengan alat kalibrator yaitu fetal simulator, menurut standar alat di Loka Pengamanan Fasilitas Kesehatan (LPFK) output yang digunakan diantaranya 60, 90, 120, 150, 180, dan 240 BPM. Penelitian ini bertujuan untuk membuat alat Simulator BPM Untuk Fetal Doppler dengan penambahan pemilihan BPM 60 hingga 240 dengan kenaikan 30 dengan menggunakan selenoid sebagai pengganti detak jantung dan rangkaian elektronika pendukung lainnya. Pada pengukuran BPM 60 terdapat nilai error 0,027%, BPM 90 terdapat nilai error 0,034% , BPM 120 terdapat nilai error 3,3%, BPM 150  terdapat nilai error 0,031%, BPM 180 terdapat nilai error 0,031%, BPM 210 terdapat nilai error 0,019%, dan nilai error terkecil yaitu 0% pada titik pengukuran BPM 240.  Alat Simulator BPM untuk Fetal Doppler dapat berfungsi dengan baik karena memiliki nilai error di bawah toleransi ±5 untuk BPM pada fetal doppler.