Fahmi, M. Rizal
Department of Architecture, Faculty of Architecture, Design, and Planning, Institut Teknologi Sepuluh Nopember (ITS), Kampus ITS Sukolilo, Surabaya 60111, Indonesia

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Cross Ventilation in High-Rise Apartment Building: Effect of Ventilation Shaft Aperture Configuration on Air Velocity and Air Flow Distribution Fahmi, M. Rizal; Defiana, Ima; Antaryama, I. Gusti Ngurah
IPTEK Journal of Proceedings Series No 1 (2018): 3rd International Seminar on Science and Technology (ISST) 2017
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j23546026.y2018i1.3509

Abstract

Ventilation shaft can be used in apartment units to provide cross ventilation by creating a pressure difference between the room’s windward opening and outlet at the roof. The previous research about ventilation shaft has shown its potential in providing good natural ventilation in high-rise apartment building. This paper examines the influence of ventilation shaft aperture configuration on its ability to generate air movement and uniform flow distribution. The experiment is carried out using computational fluid dynamics with RNG k-e calculation method. Ventilation shaft system with a uniform aperture can produce very high air velocity only at the top floor while ventilation shaft system with internal aperture size increased from the upper floor to the lower floor can produce better air flow distribution