Afrian, Noza
Unknown Affiliation

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Analisa Kinerja Electrostatic Precipitator (ESP) Berdasarkan Besarnya Tegangan DC Yang Digunakan Terhadap Perubahan Emisi Di Power Boiler Industri Pulp And Paper Afrian, Noza; Firdaus, Firdaus; Ervianto, Edy
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 2, No 2 (2015): Wisuda Oktober Tahun 2015
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Coal-fired power plant can be a source of air pollution if the combustion of coal is not handled properly. The ash from the combustion of coal in a boiler to produce fly ash and bottom ash. Based on this condition, required tools to reduce or control the fly ash. The most effective tool to be used is the electrostatic precipitator (ESP). This observation purposes to Analyze the performance of ESP by the magnitude of the DC voltage used and able to improve the performance of ESP based on the magnitude of the voltage used to changes in emissions. Based on the observations made that the greater the emissions into the ESP, the greater the voltage, which is the actual maximum voltage of 70 kV and a maximum emission incoming (135 mg/Nm3), as well as the efficiency of ESP is also influence by the voltage generated, the greater the voltage generated then the efficiency would be increase.Keywords: Electrostatic precipitator (ESP), voltage, emissionsÂÂ