Claim Missing Document
Check
Articles

Found 5 Documents
Search
Journal : Perfecting a Video Game with Game Metrics

Performance analysis for three cases of outage probability in one-way DF full-duplex relaying network with presence of direct link Phu Tran Tin; Van-Duc Phan; Le Anh Vu
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 19, No 4: August 2021
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v19i4.17477

Abstract

In this paper, the one-way decode-and-forward (DF) full-duplex relaying network system with presence of direct link is investigated. In the analysis section, we derived the exact, lower, and upper bound for outage probability (OP) with maximal ratio combining (MRC) at the receiver. Furthermore, the system performance's analytical expressions are verified by using the Monte Carlo simulation. In addition, we investigated the effect of the main parameters on the OP of the proposed system. Finally, we can sate that the simulation curves overlap the analytical curves to convince the analysis section. This research can provide a novel recommendation for the communication network.
Lower and upper bound intercept probability analysis in amplifier-and-forward time switching relaying half-duplex with impact the eavesdropper Phu Tran Tin; Van-Duc Phan; Tan N. Nguyen; Nguyen Thai Bao; Nguyen Ngoc Diem; Nguyen Duc Thinh; Minh Tran
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 19, No 5: October 2021
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v19i5.17681

Abstract

In this paper, we proposed and investigated the amplifier-and-forward (AF) time switching relaying half-duplex with impact the eavesdropper. In this system model, the source (S) and the destination (D) communicate with each other via a helping of the relay (R) in the presence of the eavesdropper (E). The R harvests energy from the S and uses this energy for information transferring to the D. For deriving the system performance, the lower and upper bound system intercept probability (IP) is proposed and demonstrated. Furthermore, the Monte Carlo simulation is provided to justify the correctness of the mathematical, analytical expression of the lower and upper bound IP. The results show that the analytical and the simulation curves are the same in connection with the primary system parameters.
Lower and upper bound form for outage probability analysis in two-way of half-duplex relaying network under impact of direct link Phu Tran Tin; Van-Duc Phan; Tan N. Nguyen
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 19, No 1: February 2021
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v19i1.15265

Abstract

In this paper, the system performance of the two-way of half-duplex (HD) relaying network under the impact of the direct link is studied. The model system has two sources (S) and one destination (D) communicate by direct link and via relay (R). For system performance analysis, we derived the lower and upper bound for outage probability (OP). Furthermore, the analytical expressions of the system performance are verified by using the Monte Carlo simulation in the effect of main parameters. As shown in the results, we can the simulation and analytical results have a good agreement.
Extended state observer based load frequency controller for three area interconnected power system Van Van Huynh; Phong Thanh Tran; Tuan Anh Tran; Dao Huy Tuan; Van-Duc Phan
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 19, No 3: June 2021
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v19i3.18777

Abstract

In this paper, we develop a new extended state variable observer based LFC scheme for three-area interconnected power systems. The extended state observerbased load frequency controllers are developed which utilize disturbance estimation techniques. The propose control approach assures that the fluctuating things of the load frequencies reaches to a safer range and the load frequencies can also be made at a very minimal not to have an effect on power quality and power flow in multi-area interconnected power system. The results of the simulations using MATLAB/SIMULINK done did not only address that the proposed newly control method works effectively but also change powerfully the parameter variations of the interconnected areas of the power system. Especially, it works very well to limit disturbances impact on interconnected areas in the system. Therefore, the performance of interconnected power system under different multi-conditions is simulated with the new control method to demonstrate the feasibility of the system.
Lower and upper bound form of outage probability in one-way AF full-duplex relaying network under impact of direct link Phu Tran Tin; Van-Duc Phan; Le Anh Vu
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 19, No 4: August 2021
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v19i4.17683

Abstract

This paper proposed and investigated the one-way amplify-and-forward (AF) full-duplex relaying network under impact of direct link. For the system performance analysis, the exact and lower and upper bound form of the system outage probability (OP) are investigated and derived. In this system model, authors assume that the E uses the MRC (maximal ratio combining) technique. Finally, we can see that the analytical and the simulation values overlap to verify the analytical section using the Monte Carlo simulation. Also, we investigate the influence of the system primary parameters on the proposed system OP.