Independent high voltage DC source development for renewable-grid integration interface Omar Abu Hassan; Shamsul Aizam Zulkifli; Mohd Shamian Zainal; Ahmad Alabqari Ma' Radzi; Muhammad Shukri Ahmad; Tengku Nadzlin Tengku Ibrahim
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 11, No 1: March 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (824.554 KB) | DOI: 10.11591/ijpeds.v11.i1.pp374-381

Abstract

Recent advancement in renewable-grid integration research, due to the concern on the environmental impact, leads to extensive study in isolated power converter as their interface. As part of isolation capability in power converter interface, extensive study of magnetic component has been carried out, especially on the design, construction and optimisation to achieve optimal operation. One of the main issue in verifying the analytical power loss model is to have independent HVDC link power source for an experimental validation work. This paper focus on the design and construction of DC link source, to be use in the experimental rig setup. Several DC link source option has been evaluated, and TDK-lambda PF500-360A power supply was selected due to the availability and excellent energy efficiency offered, at better price. External circuit is designed and implemented to achieve desired voltage and current supply characteristic. At the end, the voltage and current of the DC link supply for Dual H-bridges is obtained and shown promising result for experimental rig measurement and data collection work.
Magnetic particle imaging signal acquisition using second harmonic detection of magnetic nanoparticles Muhammad Mahadi Abdul Jamil; Abdulkadir Abubakar Sadiq; Muhammad Shukri Ahmad; Noordin Asimi Mohd Noor; Nur Adilah Abd Rahman; Nurmiza Othman
Indonesian Journal of Electrical Engineering and Computer Science Vol 15, No 1: July 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v15.i1.pp221-229

Abstract

This paper presents an approach for acquiring a magnetic particle imaging (MPI) signal, by utilizing the second harmonic detection of the magnetic nanoparticles tracers. An MPI signal with high signal-to-noise ratio (SNR) is crucial for high spatial resolution images that reveals the distribution of the tracers in a target area. Samples of Resovist and Perimag nanoparticles tracers were prepared in liquid and immobilised form, which were placed at some distances under the receiver coil of the single-sided MPI scanner. The samples were exposed to the excitation magnetic field generated at 22.8 kHz and a static gradient field generated with a direct current of 2 A. The non-linear magnetization response of the tracers for each spatial position is recorded in the form of voltage signal by a gradiometer pickup coil, with the second harmonic signal being extracted by a resonance circuit. The results obtained revealed that a sufficient signal from the tracers is recorded at up to 25 mm under the pickup coil, with Perimag samples inducing higher signals as compared to Resovist. The dependence of the DC gradient field on the second harmonic signal shows that the peak signal amplitude for Resovist and Perimag particles as ±5 mT and ±6 mT respectively. Additionally, the second harmonic signal amplitude increases exponentially with an increase in the excitation magnetic field. Thus, the results obtained shows the potential of this approach in acquiring high SNR MPI signals at low excitation frequency, which could be vital in reconstructing the contour images of the tracers, particularly in sentinel lymph node biopsy (SLNB) for breast cancer diagnosis.