Graphene/PSMA composite for gas sensing application Hanis Camelia Muhar; Noor Syazwana Sahar; Fauzan Khairi Che Harun; Nurul Ashikin Abdul-Kadir
Bulletin of Electrical Engineering and Informatics Vol 9, No 6: December 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v9i6.2199

Abstract

This paper presents the fabrication of conducting polymer sensor which comprise of graphene-poly styrene-co-maleic acid (PSMA) composite that responds to volatile organic compound (VOC) via a change in the electrical resistance of the sensors. Five sensors composed of different material ratio were fabricated to find out the most prominent weight percentage ratio (wt %) for optimum sensor response. Those materials were deposited onto silver electrode using drop-casting method. NI Card PCIE-6323 measures the voltage obtained from the sensor circuit and the resistance of the gas sensor monitored using LabVIEW instrument. It was observed from the experiments that combination of 60% graphene and 40% PSMA gives the highest sensor response.
Flexible ECG circuit fabrication and application using vinyl cutting technique Noor Syazwana Sahar; Nurul Ashikin Abdul-Kadir; Fauzan Khairi Che Harun
Bulletin of Electrical Engineering and Informatics Vol 9, No 6: December 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v9i6.2197

Abstract

The aim of this study is to prove the capability of vinyl cutting technique to cut the conductive traces of electronic circuit layout which used a copper tape (Copper tape 1181 from 3M) on flexible substrate to replace the method of using nano-scale particle material. A wireless electrocardiography (ECG) circuit was integrated and fabricated on flexible substrate, namely a polyethylene terephthalate (PET) substrate by using vinyl cutting method to produce the conductive line traces. After that, the fabricated circuit is used for acquiring ECG signals from a patient simulator and human subjects to measure the performance differences and compatibility as a wearable device. In the data processing stage, ECG data were denoised using sym20 from Wavelet Transform tool provided by MATLAB. Then, Signal-to-noise-ratio (SNR) was calculated and used as the signal quality indicator. At the end of the study, flexible circuit performance was compared to MIT-BIH Arrhythmia database and it shows that there is no significance difference between both. In conclusion, vinyl cutting method shows a promising fabrication output on PET substrate as the performance of both flexible ECG circuit is comparable with rigid ECG circuit by a previous study.