EVALUASI KEANDALAN BANGUNAN GEDUNG PUSKESMAS DI KABUPATEN BENER MERIAH Amtsal Amtsal; Yulia Hayati; Cut Zukhrina Oktaviani
Jurnal Teknik Sipil Vol. 16 No. 1 (2020)
Publisher : Program Studi Teknik Sipil Fakultas Teknik Universitas Atma Jaya Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (245.779 KB) | DOI: 10.24002/jts.v16i1.4218

Abstract

Puskesmas adalah bagian dari sarana pelayanan kesehatan masyarakat yang amat penting. Kabupaten Bener Meriah terdapat 3 (tiga) unit puskesmas yang masing-masing terdiri dari 2 lantai, berstatus sebagai puskesmas rawat inap dan tersebar di 3 kecamatan. Melihat usia bangunan yang sudah lebih dari 30 tahun, evaluasi tentang keandalan Puskesmas sudah selayaknya dilakukan agar tingkat keamanan pemakainnya tetap terjamin dan fungsional bangunanya dapat terwujud, sesuai dan selaras dengan lingkungannya. Tujuan penelitian ini adalah untuk mengetahui nilai keandalan bangunan gedung puskesmas di Kabupaten Bener Meriah yang sudah berumur lebih dari 30 tahun. Analisis data menggunakan metode statistik deskriptif. Menurut panduan teknis tata cara pemeriksaan keandalan bangunan gedung, 1998, Dept. PU, Permen PU No.29/PRT/M/2006, Permen PU No.45/PRT/M/2007 dan Permen PU No.26/PRT/M/2008, dimana syarat keandalan bangunan gedung adalah 95-100% Andal, 75-<95% Kurang Andal dan < 75% Tidak Andal. Hasil analisa terhadap ke-3 Puskesmas didapat nilai total keandalan bangunan gedung Puskesmas Perawatan Lampahan 65,18, Puskesmas Perawatan Bandar 64,46 dan Puskesmas Perawatan Buntul 64,87. Hasil pengujian Hammer Test pada komponen struktur menunjukan nilai rata-rata yang tergolong rendah dari yang disyaratkan untuk bangunan bertingkat.
IDENTIFIKASI POLA ALIRAN DI SEKITAR DAERAH GENANGAN BANJIR Indra Satria; Azmeri Azmeri; Yulia Hayati
Jurnal Arsip Rekayasa Sipil dan Perencanaan Vol 3, No 3 (2020): Jurnal Arsip Rekayasa Sipil dan Perencanaan
Publisher : Prodi Magister Teknik Sipil Unsyiah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/jarsp.v3i3.16646

Abstract

Johan Pahlawan Sub-district especially Leuhan Village and Blang Beurandang Village is a residential area that was hit by a flood inundation. Rainfall intensity and flow pattern conditions cause inundation. Puddles result in physical damage to home components and cause a number of losses, with varying levels of inundation and water levels. This analysis study was conducted with the aim of identifying the condition of the pattern of drainage flow around the flood inundation area. The research approach is in the form of quantitative and qualitative research. Identification results obtained: The pattern of land flow and drainage in the form of flow direction is in accordance with the topographic conditions of the study area, with channel conditions such as shrubs, constriction and at certain points with conditions of low contoured areas so that inundation is prone to improvements such as maintenance activities and repair.
Reduksi Gaya Lateral Dinding dengan RC Frame Terhadap Dinding Bata Penuh dan Dinding Bata dengan Bukaan Muhammad Habibie; Yulia Hayati; Purwandy Hasibuan
Journal of The Civil Engineering Student Vol 2, No 2 (2020): Volume 2, Nomor 2, Agustus 2020
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Struktur portal beton bertulang dengan dinding bata sangat umum dijumpai pada pekerjaan konstruksi di Indonesia. Pada praktiknya di lapangan dinding bata tidak selalu digunakan secara penuh untuk satu bentangan portal karena digunakan untuk memasang kelengkapan bangunan seperti pintu, jendela dan sebagainya. Penelitian ini dilakukan dengan tujuan untuk mengetahui dan menganalisis kapasitas reduksi gaya lateral dari portal dengan bukaan dinding bata yang dibandingkan dengan portal berdinding penuh dengan cara memberikan beban siklik lateral pada benda uji sampai displacement rencana tercapai kemudian push over sampai hancur. Hasil dari penelitian ini menunjukkan nilai reduksi kapasitas gaya lateral terbesar dialami oleh benda uji dengan bukaan dinding 40% yaitu sebesar 6,80 tonf atau 52,2%, sedangkan reduksi kapasitas gaya lateral terkecil dialami oleh benda uji dengan bukaan dinding 25% yaitu sebesar 5,59 tonf atau 42,9%.