Tukiman Tukiman
PRPN - BATAN

Published : 5 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 5 Documents
Search

REKAYASA ISOLATOR PANAS PERALATAN UJI SAMPEL PASIR ZIRKON Tukiman Tukiman
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 5, No 9 (2008): Juni 2008
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2459.626 KB)

Abstract

ABSTRAK REKAYASA    ISOLATOR  PANAS  PERALATAN  UJI  SAMPEL  PASJR ZIRKON,   Telah dibuat isolator panas peralatan  uji sampel pasir zirkon dalam bentuk padat dari bahan campuran batu tahan api,   tanah liat dan silikat yang dibentuk menjadi agregat dengan perbandingan  volume 1 : 1 : 0.2.  Isolator   dibagian   luarnya  ditambahkan  lapisan glass  wol setebal  150 mm dan serat asbes,   yang  berfungsi  untuk pengungkung  panas  dan  mengurangi  perpindahan  panas  yang terjadi pada  waktu operasi. Keberadaan  peralatan tungku pemanas  sebagai  peralatan utama dalam  penelitian   ini,  digunakan   untuk  pemanasan   sampel  hingga  suhu   1000o C.   Metode pembuatan agregat   menjadi   isolator   dilakukan   dengan   cara  mendiamkan   agregat,    dan memanaskan pada suhu 300 ° C konstan selama 6 jam. Dari hasil percobaan yang dilakukan selama 8 jam pemanasan  terus menerus isolator pemanas dapat berfungsi dengan baik. Kata kunci:   Isolator padat,  tungku pemanas.  ABSTRACT HEATER ISOLA TOR ENGINEERING  ON TEST EQUEPMENT  OF ZIRCON-SAND  SAMPLE. A heater isolator  for a test equipment  of solid zircon -sand,   which is made by an aggregate  of refractory  brick,  clay,  and silicate  with volume composition  1  :   1  :  0,2  respectively,   was made. The Isolator has been made by heating the aggregate at    300 °C constant temperature  for six hours.   A  layer  of glass-wall  with  150 mm  thickness  and  asbestos-fiber  are provided  at  the outside  of  the  isolator  to isolate  the  heat  produced  by  the  furnace  filament.   The operation temperature  of  the  furnace  will  be  1000 °C.  From  the  experiment  conducted  at  8 hours  of furnace operation shows that the isolator works propely.Keyword:  Solid isolator,  electric furnace
PENENTUAN JENIS DAN TEBAL BAHAN PERISAI MENGGUNAKAN SUMBER GAMMA Cs-137 Tukiman Tukiman
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 5, No 10 (2008): Nopember 2008
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1917.926 KB)

Abstract

ABSTRAK PENENTUAN JENIS DAN TEBAL BAHAN PER/SA/  MENGGUNAKAN SUMBER GAMMA Cs-137. Telah dilakukan penentuan jenis  bahan penahan radiasi dengan menggunakan sumber gamma Cs-137 aktivitas 74 GBq.  Pemilihan bahan perisai radiasi  diperlukan untuk mendapatkan bahan  yang  tepat,   karena  setiap  bahan  mempunyai  tebal  paruh  yang berbeda. Tebal paruh  merupakan tebal bahan yang  dapat menyerap setengah intensitas paparan radiasi sehingga paparan yang tersisa menjadi setengah dari intensitas awalnya. Sampel yang digunakan unfuk pengujian adalah beton,  kayu dan timbal dengan ketebalan bervariasi. Dari  data  percobaan dan hasil perhitungan didapatkan kesimpulan,  bahwa jenis bahan perisai dari timbal mempunyai daya serap radiasi dan nilai HVT yang tepat untuk penahan radiasi gamma : tebal paruh  timbal  0.732 cm.  Dibandingkandengan bahan   dari kayu  dengan tebal  paruh: 11. O cm dan beton  3.164 cm. Kata kunci:   Jenis bahan, tebal paruh, ,  bahan perisai.  ABSTRACTDETERMINATION OF MATERIAL AND ITS THICKNESS FOR Cs-137 GAMMA SOURCE SHIELDING. Its has been determined the shielding material and its thickness necessarily conducted due to every material will have different half-thickness characteristics, and by the selection a suitable material and its thickness  will be obtained. Half-thickness of any material is the ability of the material  at a certain thickness to absorb any radiation intensity-so that the intensity becomes half of its source. Sample materials to be used are concrete,  wood, and lead with their thickness varied. From experiment data and theoretical computation can be concluded that lead is the suitable material for shielding with the value of HVT for gamma radiation 0.732 cm. For wood and concrete will give half-thicknessof 11.0 cm and 3.164 cm respectively. Keywords: shielding  material, half-thickness, shielding
PEMBUATAN DIAGRAM ALIR PENGOLAHAN AIR BEBAS MINERAL DENGAN PENUKAR ION UNTUK PABRIK YELLOW CAKE DARI URANIUM HASIL SAMPING PABRIK ASAM FOSFAT Tukiman Tukiman; Puji Santoso
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 10, No 1 (2013): Juni 2013
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (4102.927 KB)

Abstract

ABSTRAK.PEMBUATAN  DIAGRAM ALIR  PENGOLAHAN AIR  BEBAS MINERAL  DENGAN PENUKAR  ION  UNTUK  PABRIK  YELLOW  CAKE  DARI  URANIUM  HASIL  SAMPING PABRIK  ASAM  FOSFAT.Telah dilakukan pembuatan  diagram  alir  pengolahan  air  bebas mineral dengan menggunakan resin penukar ion untuk  pabrik yellow cake dari uranium hasil samping pabrik  asam fosfat. Dasar pembuatan     diagram alir   ini adalah requirement dari kebutuhan air bebas mineral untuk proses  pabrik yellow cake  yaitu sebesar 16369   kg/jam. Plant  dioperasikan  8 jam  sehari,  diperlukan  sistem  pengolahan  air bebas mineral  untuk memenuhi kebutuhan tersebut. Sarana dan peralatan yang diperlukan untuk membuat instalasi air bebas mineral   adalah: air baku, pompa,  bak penampung air baku,  saringan pasir, tangki kation,  tangki anion,  pembubuh resin dan bak penampung air bebas mineral. Air bebas mineral untuk proses pada pabrik yellow  cake   ini beroperasi  dengan kapasitas 60 m3/jam,   8 jam operasi =  480 m3 .  Volume resin kation = 1035  liter,  Volume resin anion = 2229 liter dan volume resin mix bed = 2566 liter. Untuk mengalirkan dan pengaturan aliran air diperlukan pipa dan katup-katup sebagai peralatan pengendalian. Hasil dari rancangan ini adalah gambar diagram alir pengolahan air bebas mineral untuk pabrik yellow cake.Kata kunci: Diagram alir, pengolahan, penukar ion,  air bebas mineral. ABSTRACTA FLOW CHART CONSTRUCTION OF DEMINERALIZED WATER TREATMENT BY ION EXCHANGERS FOR YELLOW CAKE PLANT FROM BY PRODUCT OF PHOSPHORIC ACID PLANT. A flow chart of demineralized water treatment using ion exchange resin for plant yellow cake from by product of phosphoric acid plant has been created. Basis of this flow chart construction is the mineral -  free water requirement for the yellow cake plant at 16389 kg/hour. The plant  will be operated at  8 hours per  day so  that it requires the demineralized water treatment .     Facilities and equipment necessary to make the installation of demineralized water are:   raw  water,  pump,   raw  water  tank,   sand  filter,  cation  tank,   anion  tank, resin  and demineralized water tank.  The demineralized water for this yellow cake plant operates with a capacity of 60 m3/hr, 8 hours of operation 480 m3,  volume 1035 liters cation resin,  anion resin volume 2229 liters and the volume of 2566 liters of resin mixbed.   To drain the water flow and settings,  it uses pipe and valve as control equipment. The result of this design is as a flow chart of demineralized water treatment for yellow cake plant.Keywords: flow chart, processing, mineral-free water.
PERHITUNGAN DAN PEMILIHAN POMPA PADA INSTALASI PENGOLAHAN AIR BEBAS MINERAL IRRADIATOR GAMMA 200 kCi Tukiman Tukiman; Puji Santoso; Ari Satmoko
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 10, No 2 (2013): November 2013
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3364.965 KB)

Abstract

ABSTRAK PERHITUNGAN  DAN PEMILIHAN POMPA  UNTUK INSTALASI PENGOLAHAN  AIR BEBAS   MINERAL PADA  IRADIATOR  GAMMA 200  kCi.  Telah  dilakukan   perhitungan dan pemilihan  pompa pada instalasi pengolahan air bebas mineral irradiator  gamma kapasitas 200 kCi. Pompa diperlukan untuk  mengalirkan  air bebas mineral.  Metode perhitungan didasarkan pada  tahapan  perhitungan diameter pipa   dan   kecepatan  alir,  kehilangan  tekanan  karena gesekan dalam  pipa, fitting dan tabung-tabung filter, head pompa dan  net positive  suction  head. Kapasitas pengolahan air  bebas mineral dirancang dengan kapasitas  3  m3/jam  atau   setara dengan 50 liter/menit. Dari hasil  perhitungan yang  dilakukan  diperoleh hasil:  diameter pipa   25 mm, friction loss pipa  dan  peralatan  1,18  m, NPSHA  hasil perhitungan 7,05  m, dan  head total pompa 33,1  m.   Pompa yang  dipakai  adalah jenis  sentrifugal yang  mempunyai NPHSR  lebih kecil dari nilai NPSHA.  Dari perhitungan diperoleh daya pompa 0,592  HP, daya  listrik 436 Watt, dengan faktor  keamanan 1,2.  Maka  dengan melihat  head total  pompa, NPSHA,  dan  daya pompa serta kapasitas atau debit  pompa dipilih pompa Lowara  type  2HM5 dengan spesifikasi daya   0,6  HP,  daya   listrik  550  Watt,  tegangan input  220V/AC  satu   phase, dan  jenis  motor kapasitor.Kata kunci: pompa, perhitungan, pemilihan, air demineral, iradiator  ABSTRACT THE PUMP  CALCULATION AND SELECTION FOR  THE DEMINERALIZED WATER TREATMENT PLANT IN 200  kCi GAMMA IRRADIATOR. The pump  calculation and  selection for the  demineralized water  treatment plant  was performed. The  plant  is a part  of the  200  kCi gamma irradiator.  A pump  is  needed to  flow demineral  water.  The  method of calculation is based on pipe diameter calculation and its flow rate,  pressure drop due to the friction in pipes, in fittings  and  in tube  filter, pump  head and  the  net  positive  suction  head. The  capacity of the demineralized water  treatment plant  is designed at  3  m3/jam  equivalent to  50  liters/min. The results are:  25 mm of iameter pipe, 1.18 m of friction loss  due to pipe and  its equipment, 7.05 m of NPSHA  and  33.1  of   the  total  head the  pump.  The  pump  is  centrifugal model  having  the NPHSR  value less than  the NPSHA one.  The calculation obtained a pump  power  at 0.592  hp or 436  Watt electric  power,  with the  safety  factor  of 1.2.  By considering the  pump  total head, the NPSHA,  the power  consumption, and  the discharge capacity, it is decided to use  Lowara  pump type  2HM5.  Its  specifications are  0.6  HP  of  power,   550  Watt  of  power  consumption, input voltage  at 220V/AC, 50 Hz, 1 phase, and  the motor is capacitor type. Keywords:  pump,  calculation, selection, demineralized water,  irradiator
TEKNIK PELACAKAN KERUSAKAN DAN PERBAIKAN TUNGKU PEMANAS KLORINASI Tukiman Tukiman
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 4, No 7 (2007): Juni 2007
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2574.826 KB)

Abstract

ABSTRAK TEKNIK  PELACAKAN   KERUSAKAN   DAN  PERBAIKAN   TUNGKU  PEMANAS   KLORINASI. Telah dilakukan pelacakan  dan penelusuran  kerusakan    pada tungku pemanas  klorinasi  pasir zirkon  di laboratorium   Teknologi  Proses  PTAPB  BATAN. Teknik pelacakan  dilakukan  dengan cara pengecekan   pada sistem pemanas,  kontak-kontak   mekanik,     instalasi  listrik  dan sensor suhu.  Terjadi  kerusakan   pada   sistem   pemanas/kawat    nikelin  yang   hubung   terbuka/putus. Selanjutnya dilakukan langkah-langkah  perbaikan dengan mengganti elemen pemanas  berupa kawat  nikellin   yang  putus.    Sedangkan   pada  sistem   kelistrikan       dilakukan   penggantian penghantar  berupa  kawat NYY 2,5  mm dan selongsong  asbes,      sensor  suhu diganti  dengan peralatan/alat  ukur dari sistem yang terpisah.    Dari hasil perbaikan   dan  telah   dilakukan  uji coba pemanasan  selama 8  jam  terus menerus,   dapat disimpulkan   bahwa  pemanas  dapat digunakan untuk proses dengan suhu yang dapat dicapai sampai  1100 °C.   Secara disain tel ah memenuhi persyaratan  untuk proses klorinasi. Kata kunci:   Sistem pemanas,  perbaikan, temperatur  suhu.  ABSTRACT TROUBLESHOOTING  AND REPAIRE TECHNIQUE FOR CHLORINATION  FURNACE.. A troubleshooting  and repaire  have been conducted for the chlorination  furnace  at the technology process laboratory  of PTAPB -BATAN.  The troubleshooting  is began by checking  of the heater element,   mechanical  switches,  electric  instalation   and the temperature  sensor.  It is found that the heater element has been defective and replacement  using nickelin wire is done completed as  well as.   Its  electric  cable  to the  element  using  NYY  2,5   mm including  its  isolation.  The temperature  sensors  are  replaced  with  a  new  system  as   they  cannot  to  be  repaired.   The repaired  furnace  has   been  tested  for  8  hours  continously  at  1100   °C   of  temperature.    It is concluded that the  furnace  system can be used for the chlorination process after  the repaire. Key word:   furnace system,  repaire,  temperature