Endang Sutisna Sulaeman
Faculty of Medicine, Sebelas Maret University

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Perbedaan Efektivitas antara Sterilisasi Dialyzer secara Manual dan Otomatis di Rumah Sakit DR.Moewardi Dezca Nindita; . Hudiyono; Endang Sutisna Sulaeman
Nexus Biomedika Vol 2, No 2 (2013): Nexus Biomedika
Publisher : Nexus Biomedika

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (13.862 KB)

Abstract

Background: Dialyzer is a critical medical equipment having high risk of microorganism contamination. Because of economical reason, dialyzer reuse is performed as first choice in Indonesia. The making of dialyzer reuse starts from rinsing, priming test and sterilization itself. Sterilization method of dialyzer that has been carried out in Rumah Sakit Dr. Moewardi is manual and automatic sterilization. Method: This was an observational study using cross sectional design. Samples taken by consecutive sampling technique were collected from the last rinsing of NaCl right before the dialyzer was used. This NaCl samples were collected from dialyzer which were sterilized manually and automatically, each, 15 samples. The difference of posistive growth of bacteria cultures of both methods was analyzed by Chi square test, while the difference of the number of colony forming unit was analyzed by independent T test. Result: Fifteen samples of the last rinsing of NaCl from dialyzer sterilized manually showed there were 10 samples positive contaminated and 5 samples negative. While from dialyzer sterilized automatically showed there were 8 samples positive contaminated and 7 samples negative. All positive samples were contaminated by positive Gram bacteria. The statistical analyses showed no significant difference of both based on quality (p = 0.456) and quantity (p = 156). Conclusion: There was bacterial contamination as many as 10 samples (66.6%) of dialyzer which was sterilized manually and 8 samples (53.3%) of dialyzer which was sterilized automatically. There was no significant difference statistically on the effectiveness between manual and automatic sterilization. Keywords: dialyzer reuse, manual sterilization, automatic sterilization.
Hubungan Anemia Dengan Hipotermia Pada Neonatus Di RSUD Dr. Moewardi . Ardiningsih; Dwi Hidayah; Endang Sutisna Sulaeman
Nexus Kedokteran Klinik Vol 2, No 2 (2013): Nexus Kedokteran Klinik
Publisher : Fakultas Kedokteran Universitas Sebelas Maret Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Background: Based on data from Departemen Kesehatan Republik Indonesia (2007), one of the causes of death in the first 24 hours of life is hypothermia. Hypothermia is caused by the reduction of heat production. The production of heat in of neonates are strongly associated with the supply of oxygen. Anemia is bodys condition with haemoglobin levels below normal score according to age and gender. The oxygen supply to tissues is reduced if haemoglobin level is decreased, causing the reduction of heat production. The aim of this research is to know about the association between anemia and hypothermia on neonates. Methods: This is an observational analytic research with cross sectional design. This research was done in RSUD Dr.Moewardi. The samples were the neonates who were treated in the High Care Unit (HCU) of neonates in RSUD Dr.Moewardi on the 3rd until 15th of March 2013. Dependent variable was hypothermia, and the independent variable was anemia. The neonates haemoglobin levels were measured then the neonates temperature were observerd every 3 hours for 24 jam. The data were analyzed using fisher test, because the requirements of chi-square test were not met. Result: The results from fisher test were p = 0,225. Conclusion: The analysis showed there was not association between anemia and hypothermia in this research. Keyword: anemia, hypothermia, neonates