Aplikasi Klinik Renograf IR-03 untuk Rumah Sakit: Teknologi dan Analisis Biaya Isaris, Rill
Jurnal Kedokteran YARSI Vol 20, No 2 (2012): MEI - AGUSTUS 2012
Publisher : Lembaga Penelitian Universitas YARSI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (279.783 KB) | DOI: 10.33476/jky.v20i2.164

Abstract

Teknik Renografi menggunakan Alat Renograf adalah salah satu modalitas pemeriksaan fungsi ginjal selain dengan pemeriksaanlaboratorium dan teknik Sinar-X. Prototip Renograf IR-03 untuk pemeriksaan fungsi ginjal hasil rancangbangun BATAN telah dikonstruksi dan menjalani uji laboratorium di PRPN-BATAN Serpong dan uji klinis di RSUP DR.Sardjito Jogyakarta. Biaya yang berkaitan dengan pemakaian klinik Alat Renograf di rumahsakit telah dianalisis yang terdiri dari komponen nilai radiofarmaka dan nilai investasi alatRenograf. Perhitungan biaya radiofarmaka hippuran Iodine per tahun dengan estimasi jumlah pasien 2000 orang sebesar Rp 30 juta, Total Direct Cost adalah Rp 212,5 juta dan biaya modal satu Alat Renograf sebesar Rp 250 juta. Nilai Titik Impas (Break Event Point) Investasi satu Alat Renograf adalah 1194 (0,597%) atau setara Rp 209,475 juta, dengan biaya per prosedur adalah Rp 85.000,-. Harga ini tergantung pada beberapa variable terutama volume (kapasitas pelayanan pasien). Perhitungan analisis Cash-Flow untuk melihat seberapa jauh investasi tersebut menarik dan memberi prospek ke masa depan menunjukkan nilai Rate of Return yang diperoleh yaitu ROR (i) adalah 22,6%, jauh diatas suku bunga simpanan Bank saat ini yaitu <10%. Perhitungan analisa Payback Period menunjukkan nilai 1,818 tahun, sangat prospektif secara ekonomi.
DESIGN AND CONSTRUCTION OF RENOGRAPH FOR RENAL FUNCTION TEST USING CsI(Tl) DETECTOR AND MICROCONTROLLER AT89C51 -, Setyadi; Isaris, Rill
JURNAL TEKNOLOGI TECHNOSCIENTIA Academia Ista Vol 12 No 01 Agustus 2007
Publisher : Lembaga Penelitian & Pengabdian Kepada Masyarakat (LPPM), IST AKPRIND Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (328.454 KB) | DOI: 10.34151/technoscientia.v0i0.1996

Abstract

The development of Renograph prototypes for renal function testing has been initiated in BATAN since 1983, five generation prototypes using NaI(Tl) Scintillation de-tector have been successfully constructed and utilized in hospitals. Due to the new re-gulation for human safety, then the use of low energy radioisotopes with shorter half life time should be considered. It requires to develop the new instrument of higher sensitivity and better performances. This paper presents design of renograph using CsI(Tl) scintillation as a new type detector and a 16 bits Microcontroller AT89C51 as the data processor for renal function test, so renograph with a high reliable and better performances in application is achie-ved. The use of CsI(Tl) and Microcontroller as the data processor is the development made from the previous prototypes, the system is also provided with a serial commu-nication facility to Personal Computer through serial-port RS 232. Static examination to the pulses generated by a Function Generator with fre-quency up to 12.000 Hz and the dynamic test using 137Cs and 60Co radiation sources have been carried out successfully. The non-linearity integral of the system shows the response is linear up to frequency of 65.000 Hz with strong correlation coefficient, that is R2 ~ 0,9999. The calculation of the statistical feasibility counting to the both CsI(Tl) detector equipments for the two sources above with confidence level of 0,95 give the χ2 are 0.238 and 0.078. These are much smaller than the χ2 value in the table, that is 0.711 for N = 5. Hence, the modified renograph system using CsI(Tl) and Microcontroller AT89C51 has good counting linearity and fulfills the counting feasibility statistically.
DESIGN AND CONSTRUCTION OF RENOGRAPH FOR RENAL FUNCTION TEST USING CsI(Tl) DETECTOR AND MICROCONTROLLER AT89C51 -, Setyadi; Isaris, Rill
JURNAL TEKNOLOGI TECHNOSCIENTIA Academia Ista Vol 12 No 01 Agustus 2007
Publisher : Lembaga Penelitian & Pengabdian Kepada Masyarakat (LPPM), IST AKPRIND Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.34151/technoscientia.v0i0.1996

Abstract

The development of Renograph prototypes for renal function testing has been initiated in BATAN since 1983, five generation prototypes using NaI(Tl) Scintillation de-tector have been successfully constructed and utilized in hospitals. Due to the new re-gulation for human safety, then the use of low energy radioisotopes with shorter half life time should be considered. It requires to develop the new instrument of higher sensitivity and better performances. This paper presents design of renograph using CsI(Tl) scintillation as a new type detector and a 16 bits Microcontroller AT89C51 as the data processor for renal function test, so renograph with a high reliable and better performances in application is achie-ved. The use of CsI(Tl) and Microcontroller as the data processor is the development made from the previous prototypes, the system is also provided with a serial commu-nication facility to Personal Computer through serial-port RS 232. Static examination to the pulses generated by a Function Generator with fre-quency up to 12.000 Hz and the dynamic test using 137Cs and 60Co radiation sources have been carried out successfully. The non-linearity integral of the system shows the response is linear up to frequency of 65.000 Hz with strong correlation coefficient, that is R2 ~ 0,9999. The calculation of the statistical feasibility counting to the both CsI(Tl) detector equipments for the two sources above with confidence level of 0,95 give the χ2 are 0.238 and 0.078. These are much smaller than the χ2 value in the table, that is 0.711 for N = 5. Hence, the modified renograph system using CsI(Tl) and Microcontroller AT89C51 has good counting linearity and fulfills the counting feasibility statistically.
SUATU TINJAUAN TENTANG PERALATAN KEDOKTERAN NUKLIR DAN MASALAH PEMELIHARAANNYA Rill Isaris
GANENDRA Majalah IPTEK Nuklir Volume 7 Nomor 2 Juli 2004
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (204.709 KB) | DOI: 10.17146/gnd.2004.7.2.193

Abstract

SUATU TINJAUAN TENTANG PERALATAN KEDOKTERAN NUKLIR DAN MASALAH PEMELIHARAANNYA. Peralatan Kedokteran Nuklir (PKN) tergolong rumit serta memerlukan perhatian untuk mempertahankan agar tetap berada dalam kondisi operasional yang baik, dan terdapat berbagai kendala dalam melaksanakan perawatannya terutama di negara sedang berkembang. Beberapa kendala yang terdeteksi adalah akibat gangguan kondisi lingkungan, tidak adanya dukungan engineer dari pabrik alat, tidak memadai staf lokal terlatih, kesulitan mendapatkan spareparts, komplikasi administratif, masalah dana, dsb-nya. Dalam makalah ini dikemukakan dan dibahas secara ringkas faktor tersebut berdasarkan pengalaman melaksanakan perawatan peralatan kedokteran nuklir di berbagai rumahsakit, selanjutnya dikemukakan catatan perawatan peralatan Gamma Camera dan kondisi saat ini sebagai ilustrasi. Juga dikemukakan upaya yang harus dilakukan dalam suatu sistem perawatan komprehensif terutama untuk peralatan kedokteran nuklir yang masih operasional dan atau yang baru. Dikemukakan pula organisasi dan manajemen sistem perawatan maju yang meliputi komponen : 1) kesehatan laboratorium, 2) pemeliharaan preventif dan 3) pemeliharaan korektif untuk dapat diadopsi. Berdasarkan review pada pengalaman negara-negara sedang berkembang, mengembangkan kemampuan sendiri dalam melaksanakan perawatan alat adalah sangat penting, karena dengan menggunakan sistem kontrak akan sangat mahal dan selalu tergantung pihak lain. Utuk meningkatkan keandalan dan memperbaiki kualitas PKN perlu dilakukan program kendali kualitas secara rutin di rumahsakit.
APLIKASI KLINIK RENOGRAF IR-03 UNTUK RUMAHSAKIT: TEKNOLOGI DAN ANALISIS BIAYA Rill Isaris; Suharni Suharni
GANENDRA Majalah IPTEK Nuklir Volume 14 Nomor 2 Juli 2011
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1190.138 KB) | DOI: 10.17146/gnd.2011.14.2.35

Abstract

APLIKASI KLINIK RENOGRAF IR-03 UNTUK RUMAHSAKIT: TEKNOLOGI DAN ANALISIS BIAYA. TeknikRenografi menggunakan Alat Renograf adalah salah satu modalitas pemeriksaan fungsi ginjal selain denganpemeriksaan laboratorium dan teknik Sinar-X. Renograf IR-03 untuk pemeriksaan fungsi ginjal hasil rancangbangunBATAN telah dikonstruksi dan menjalani uji laboratorium di PRPN-BATAN Serpong dan uji klinis di RSUPDR.Sardjito Jogyakarta. Biaya yang berkaitan dengan pemakaian klinik Alat Renograf di rumahsakit telah dianalisisyang terdiri dari komponen nilai radiofarmaka dan nilai investasi alat Renograf. Perhitungan biaya radiofarmakahippuran 131Iodine per tahun dengan estimasi jumlah pasien 2000 orang sebesar Rp. 30 juta, Total Direct Costadalah Rp. 212,5 juta dan biaya modal satu Alat Renograf sebesar Rp. 250 juta. Nilai Titik Impas (Break EventPoint) Investasi satu Alat Renograf adalah 1194 (0,597%) atau setara Rp. 209,475 juta, dengan biaya per proseduradalah Rp. 85.000,-. Harga ini tergantung pada beberapa variable terutama volume (kapasitas pelayanan pasien).Perhitungan analisis Cash-Flow untuk melihat seberapa jauh investasi tersebut menarik dan memberi prospek kemasa depan menunjukkan nilai Rate of Return yang diperoleh yaitu ROR ( i*) adalah 22,6%, jauh diatas suku bungasimpanan Bank saat ini yaitu <10%. Perhitungan analisa Payback Period menunjukkan nilai 1,818 tahun, sangatprospektif secara ekonomi.Kata kunci : Analisis biaya, renograf diagnostik, diseminasi produk