KOMBINASI PENAMBAHAN SHIELDING TIMBAL MESIN FLUOROSCOPY BAGASI DAN PENGATURAN JARAK PEKERJA TERHADAP SUMBER RADIASI MENURUNKAN PAPARAN RADIASI SINAR X DAN KELELAHAN MATA PADA PEKERJA SCREENING DI BANDARA INTERNASIONAL X Maghfirotul Iffah; I Putu Gede Adiatmika; I Wayan Bandem Adnyana; I Dewa Putu Sutjana; I Made Muliarta; Ida Bagus Alit Swamardika
Jurnal Ergonomi Indonesia (The Indonesian Journal of Ergonomic) Vol 4 No 1 (2018): Volume 4 No 1 Juni 2018
Publisher : Program Studi Magister Ergonomi Fisiologi Kerja Pascasarjana Universitas Udayana Denpasar Bekerjasama dengan Perhimpunan Ergonomi Indonesia (PEI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEI.2018.v04.i01.p01

Abstract

Screening is ordinary process airport passanger was machine baggage. X-ray radiation gives impact to eye because eye sensitive of radiation. Many kinds of eye strain symptom got by screening worker such eye poignant. It is neressary to give intervention to decrease the radiation exposure and eye strain for worker by increasing lead shielding on the fluoroscopy machine baggage and setting of worker distance toward the source of radiation. Experimental research with pre-post test control group design. A sampel of 30 people were taken with a simple randomized method which was subdivided into group 1 as a control group without the additional treatment of lead shielding and working distance regulation of the radiation source, group 2 with the addition of a shielding and setting distance as far as 2 m. the study was conducted in August 2017. The variables evaluated were exposure to the received radiation of workes and the strain of the workers eyes. The result of the research is a combination of lead shielding on machine baggage fluoroscopy and setting of working distance to X ray source at X International Ariport significantly (p<0,05) in decreasing radiation exposure received by worker equal to 74,59% and worker eye strain 68,85% for a distance of 1,5 m and decreased radiation exposure to the workers as much as 93, 69% and the eye strain on the worker 89,79% at a distance of 2 m from the radiation source. Concluded that the combination of increasing lead shielding and the setting of worker distance toward the source of radiation decrease thr radiation exposure and eye strain on the screening worker at X International airport.
Pengaruh Variasi Tegangan Tabung Sinar-X terhadap Signal to Noise Ratio (SNR) dengan Penerapan Anode Heel Effect menggunakan Stepwedge Puja Satwika Luh Gede; Ni Nyoman Ratini; Maghfirotul Iffah
BULETIN FISIKA Vol 22 No 1 (2021): BULETIN FISIKA February Edition
Publisher : Departement of Physics Faculty of Mathematics and Natural Sciences, and Institute of Research and Community Services Udayana University, Kampus Bukit Jimbaran Badung Bali

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/BF.2021.v22.i01.p04

Abstract

It has been conducted research to determine the effect of X-ray tube voltage variation (kV) on Signal to Noise Ratio (SNR) values by applying the Anode Heel Effect using stepwedge with the addition of 1.5 mm thickness each step. The stepwedge used was 1.5-31.5 mm. The X-ray tube voltage variations used were 40, 50, 60, 70, 80, and 90 kV. Analysis of the effect of X-ray tube voltage variation on SNR values is determined using IMB SPSS Statistics 26 with a simple regression test. The test results showed that variations in X-ray tube voltage affect SNR values, where the greater the variation in X-ray tube voltage then the SNR value would get smaller. The optimal SNR value of 72.685 was obtained at a tube tension of 40 kV and a stepwedge thickness of 27.0 mm.