Implementasi Wireless Monitoring Energi Listrik Berbasis Web Database Irwan Dinata; Wahri Sunanda
JURNAL NASIONAL TEKNIK ELEKTRO Vol 4 No 1: Maret 2015
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (494.147 KB) | DOI: 10.25077/jnte.v4n1.120.2015

Abstract

Abstrak - Implementasi Wireless Monitoring Energi Listrik Berbasis Web Database ini dirancang untuk menggantikan sistem pengukuran energi listrik secara manual dan konvensional. Perangkat ini terdiri 4 (empat) bagian yaitu sensor, processor, display dan network. Bagian sensor terdiri dari Current Transformer dan AC to AC Power Adapter. Processor digunakan Arduino UNO yang akan mengolah hasil sensor, display menggunakan Liquid Crystal Display (LCD) tipe untuk menampilkan data keluaran real time. Dan bagian terakhir yaitu network terdiri dari Ethernet Shield, 3G Router, 3G Modem untuk komunikasi ke Database Server sebagai tempat penyimpanan tetap dan pengolahan data lebih lanjut. Pada pengujian dengan total beban nominal 120 watt menunjukkan bahwa nilai Vrms yang tampil di LCD Wireless Energy Monitoring sebesar 218 volt, nilai Vrms hasil pengukuran Clamp Meter sebesar 216 volt. Untuk nilai Irms di LCD Wireless Energy Monitoritng 0,44 ampere, nilai Irms hasil pengukuran Clamp Meter 0,5 ampere. Nilai daya nyata di LCD Wireless Energy Monitoring 92 watt, nilai daya nyata hasil pengukuran Clamp Meter 84 watt. Sedangkan faktor daya di LCD Wireless Energy Monitoring 0,97 dan faktor daya hasil pengukuran Clamp Meter 0,99. Kata kunci: wireless monitoring, real power, power factor. Abstract – Web Database based wireless device for monitoring electricity consumption is designed to substitute manual and conventional measurement system. This device consists of sensor, processor, display and network. The sensor consists of current transformer and AC to AC Power Adapter. The processor is Arduino UNO which   process sensor output. Liquid crystal device (LCD) is used to display real  time  output.  The  last  part  of  the  device  is network composed of Ethernet Shield, 3G Modem for communication with Database Server as data further processing and storage. The testing with nominal total load 120 watt shows that Vrms value on LCD of the device is 218 volt, Vrms value measured with clamp meter is 216 volt. Irms value on LCD of the device is 0,44 ampere, Irms value measured with clamp meter 0,5 ampere. The real power value on LCD of the device is 92 watt, the real power value measured with clamp meter is 84 watt. The power factor value on LCD of the device is 0,97, the power factor value measured with clamp meter is 0,99. Keywords: wireless monitoring, real power, power factor.
Analisa Power Spectral Density pada Sistem Orthogonal Wavelet Division Multiplexing Berbasis Wavelet Packet Irwan Dinata
Jurnal Arus Elektro Indonesia Vol 1 No 2 (2015)
Publisher : Fakultas Teknik, Universitas Jember

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pada komunikasi nirkabel, tuntutan untuk menyediakan layanan data kecepatan tinggi dengan memberikan kinerja yang baik memunculkan teknik baru dalam peningkatan efisiensi spektrum dan perbaikan kualitas sinyal akibat Frequency Selective Fading. Salah satu teknik multicarrier yaitu Orthogonal Wavelet Division Multiplexing (OWDM). Pada OWDM, Invers Wavelet Packet Transform (IWPT) digunakan untuk membangkitkan simbol terkirim pada Transmitter dan Forward Wavelet Packet Transform (WPT) akan mengembalikan simbol data terkirim tersebut pada Receiver. Sistem OWDM ini akan membagi band frekuensi ke dalam beberapa subband yang berdiri independen dan terisolasi secara spektral yang disebut subchannelization. Dari hasil simulasi Power Spectral Density (PSD), Overlapping antar subband diperlihatkan dari titik puncak untuk subband pertama, berada di titik dasar subband selanjutnya. Daya setiap subcarrier-nya tersebar hanya di sebagian dalam subband dan side lobe untuk tiap subband tidak selebar pada Orthogonal Frequency Division Multiplexing (OFDM). Kata kunci –  Orthogonal, Power Spectral Density, Wavelet Packet