Monitoring Walking Devices For Calorie Balance In Patients With Medical Rehabilitation Needs Wahyu Andhyka Kusuma, WAK; Zamah Sari; Diah Ayu Fitriani; Siti Norhabibah; Sabrina Nurul Ubay; Hardianto Wibowo
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 5: EECSI 2018
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (418.931 KB) | DOI: 10.11591/eecsi.v5.1613

Abstract

This article presents a measurement system intended to monitor human footsteps. The goal is to guide the users medical rehabilitation incorrect use to prevent dangerous situations and maximize comfort. Indicators of risk in question: the imbalance of movement in motor coordination and the number of calories to be burned for medical rehabilitation patients by balancing the patient's needs. Measurements are made by placing the sensor on one of the patient's legs. The main sensor accelerometer used in this study. The measurement system comes with an application link that allows patients and therapists to monitor the activity. Calibration and experimental results are presented in this article.
Design of Monitoring System Step Walking With MPU6050 Sensor Based Android Diah Ayu Fitriani; Wahyu Andhyka; Diah Risqiwati
JOINCS (Journal of Informatics, Network, and Computer Science) Vol 1 No 1 (2017): April
Publisher : Universitas Muhammadiyah Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (420.736 KB) | DOI: 10.21070/10.21070/joincs.v1i1.799

Abstract

Walking is said to increase endurance, burn calories and improve cardiovascular health. To monitor the steps when walking, we need a tool that is a gyroscope sensor MPU6050. Making this tool uses a gyroscope sensor for monitoring footsteps because Gyroscope is used to measure or determine the orientation of an object based on the provisions of angular momentum. This tool has been tested by foot with a number of different steps. The device test carried out by one person testers.Data obtained from these tests resulting from the detection lower limit value and upper limit value of X axis angle data is used in data processing is the value of the X-axis is converted into a sine wave form chart. To detect footsteps, each wave has the upper value limit is 20o and the bottom value is -20o. Once the step is detected, these measures will be multiplied by the width of the foot when walking, then obtained distance