Claim Missing Document
Check
Articles

Found 4 Documents
Search

Pengaruh Penggunaan Prosthesis Transfemoral Terhadap Tingkat Kemampuan Mobilitas Pada Pasien Amputasi Transfemoral Dibalai Besar Rehabilitasi Sosial Bina Daksa (BBRSBD) Prof. Dr.Soeharso Surakarta Sri Surini Pudjiastuti; Agus Setyo Nugroho; Luluk Fuadah
Interest : Jurnal Ilmu Kesehatan Vol 6 No 2 (2017): INTEREST : JURNAL ILMU KESEHATAN
Publisher : Poltekkes Kemenkes Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37341/interest.v6i2.88

Abstract

Abstract : AMPnoPRO, AMPPRO, Transfemoral Prosthesis, Mobility Level. Transfemoral amputation is the amputation of the limbs that is performed between the hips and knees This amputation is a state that affects the patient's unthinking life. The loss of the limb causes disruption of lower limb function, thus indirectly disturbing its mobility. The purpose of this study was to determine the effect of Prosthesis on the level of mobility ability of transfemoral amputation patient. The Amputee Mobility Predictor (AMP) study on improving mobility of transfemoral prosthesis users using one-pretest and post-test group design studies, one group pretest-postes design including preexperiments. This study used a cross-sectional approach. In this design is done pretes to know the condition of the beginning of the subject before being treated so that researchers can know the condition of the subject studied before or after being treated which results can be compared or seen changes. Nine Subjects aged between 17-27 years, Using unilateral transfemoral prosthesis, muscle strength stump≥4, Normal joint motion scope. From wilcoxon statistic test obtained t = -2.687 with p = 0.007, because p <0,05, it can be concluded "there is influence of transfemoral prosthesis to the level of mobility ability in transfemoral amputation patient". The prosthesis has a higher level of mobility than the mobility level with other tools. The difference in functional level of other mobility aids (ABM) is level k-2 whereas the level of prosthesis is k-3 level.
Pengaruh Penggunaan Afo Fleksibel Dan Afo Jointed Plantar Fleksi Stop Terhadap Kecepatan Berjalan Pasien Dengan Hemiparetic Cerebrovascular Accident ( CVA ) Agus Setyo Nugroho; M. Syafi’i; Sri Surini Pudjiastuti
Interest : Jurnal Ilmu Kesehatan Vol 6 No 2 (2017): INTEREST : JURNAL ILMU KESEHATAN
Publisher : Poltekkes Kemenkes Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37341/interest.v6i2.92

Abstract

Abstract : Drop Foot, AFO Fleksibel, AFO Jointed Plantar Stop, Walking Speed, CVA. Research Objectives To determine whether there is a difference in the use of AFO Flexible and AFO Jointed Plantar Stop against the walking speed of someone who has drop foot because of CVA. The experimental quasy research method used two group pre and post test design approach. The study population was patients who had drop foot because of CVA. Statistical test result with paired t test at Flexible AFO user group walking speed shows p value 0,000 <0,05 so there is Flexible AFO effect to different speed of walking in drop foot sufferer. Result of statistical test with paired t test at walk time of user group of AFO Jointed Plantar Stop shows p value 0,000 <0,05 so there is influence of AFO Jointed Plantar Stop to difference of walking time in patient of drop foot. Statistical test results with paired t test at the walking speed of AFO Jointed Plantar Stop user group showed p value 0,000 <0,05 so that there is influence of AFO Jointed Plantar Stop to difference of walking speed in drop foot sufferer. The result of statistical test with paired t test at walk time of AFO Flexible user group with AFO Jointed Plantar Stop shows p value 0,013 <0,05 so there is time difference walking using AFO Flexible with AFO Jointed Plantar Stop on walking time in drop foot sufferer. The result of statistical test with paired t test at Flexible AFO user group speed with AFO Jointed Plantar Stop shows p value 0,012 <0,05 so there is difference of walking speed using AFO Flexible with AFO Jointed Plantar Stop to walking speed at patient of foot foot.Dengan Conclusion The use of AFO Flexible has a better walkspeed effect compared to the use of AFO Jointed plantar stop with an average difference of 0.010
Pengaruh Penggunaan Medial Arch Support Terhadap Sudut Valgus Ankle Pada Kondisi Flatfoot Agus Setyo Nugroho; Prasetyo Catur Utomo; Dewanti Nuraini
Jurnal Keterapian Fisik Vol 2 No 1 (2017): JURNAL KETERAPIAN FISIK
Publisher : Poltekkes Kemenkes Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (91.163 KB) | DOI: 10.37341/jkf.v2i1.80

Abstract

Abstract : Medial Arch Support, Valgus Ankle, Flat Foot. The purpose of this study was to determine the effect of medial arch support on the angle of valgus ankle in flat foot condition. The type of this research is ExperimentCross SectionalQuasi with one group Pre Pre and Post Test Design. In order to determine the effect of medial arch support on the angle of valgus ankle on the condition of flatfoot of children aged 10 to 12 years, the instruments, materials or tools in this study consist of (1) medialarch supportsize small (20, 22, 23) (2) goniometer (3) Stationery (4) Resulting Sheet (5)Footprint Frame. The results of the study found that there is an effect of decreasing the degree of ankle valgus in flat foot conditions. Pre post Test The left leg before and after treatment showed p = 0.000 (p <0.05). And result of pre foot test data of right foot before and after treatment showed p = 0.000 (p <0,05). From this data it can be concluded that there is influence of medial arch support to angle valgus ankle at flat foot condition.
THE EFFECT OF BOTTOM ROCKER SOLE ON KINETIC ENERGY IN TRANSTIBIAL PROSTHESIS USERS Agus Setyo Nugroho; Dody Suprayogi
Journal of Prosthetics Orthotics and Science Technology Vol. 1 No. 2 (2022): JPOST: JOURNAL OF PROSTHETICS ORTHOTICS AND SCIENCE TECHNOLOGY
Publisher : POLITEKNIK KESEHATAN KEMENKES JAKARTA I

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (995.92 KB) | DOI: 10.36082/jpost.v1i2.865

Abstract

Background : Lower limb amputation with or without the use of a prosthesis has an impact on energy consumption/needs for ambulances. There are studies that say the results of the measurement of energy used in amputated patients, namely walking with a partially amputated leg will expend more energy than the amputee. Higher than the study, it can be said that more energy expenditure results in fatigue one level above the fatigue that is experienced felt in normal people. The purpose of this study was to determine the effect of the bottom rocker sole on the kinetic energy of transtibial prosthesis users. Methods: This type of research is quasi-experimental with a pre and post test design approach. This research was conducted at APOC Clinic in April - July 2021, with the research subjects being 20 users of the transtibial prosthesis. Each research subject will be given an intervention in the form of a bottom rocker sole, then measured for kinetic energy before and after treatment. Analysis of the data in this study using the Wilcoxon test. Results: There is a statistically significant effect of the use of the buttom rocker sole on the kinetic energy of the transtibial prosthesis users (z = -2.73, mean difference 1.5 and p value = 0.006). Conclusion: The use of buttom rocker sole can increase the occurrence of kinetic energy in transtibial prosthesis users so that they can maximize their activities.