Claim Missing Document
Check
Articles

Found 1 Documents
Search

ALTERNATIF METODE ANALISIS PENETAPAN KADAR ASAM MEFENAMAT DALAM PONSAMIC 500 mg TABLET SALUT SELAPUT Syahruni Syahruni; Dian Arrisujaya
JURNAL SAINS NATURAL Vol. 6 No. 1 (2016): Sains Natural
Publisher : Universitas Nusa Bangsa

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (431.008 KB) | DOI: 10.31938/jsn.v6i1.249

Abstract

Alternative of analytical methods of assay mefenamic acid in posamic 500 mg film coated tabletThe level of active substance is a requirement that must be met to ensure the quality of medicinal preparations, to carry out the assay of the active drug substance required a method that has been validated. The validity of alternative methods of assay in ponsamic mefenamic acid 500 mg film coated tablet (trade name) has been performed. Mefanat acid assay method using UV spectrophotometry, so that the limited availability of tools that can be resolved HPLC. The validity of alternative methods tested by the parameters of accuracy with standard addition method and parameters accuracy. Based on the results obtained by the value of the linearity was r equal to 0,999 and the percentage difference spectrophotometric method with HPLC method (% difference) at 0,16%. The results showed an alternative method of assay in ponsamic mefenamic acid 500 mg film coated tablet (trade name) using spectrophotometric methods, qualified acceptance in accordance with ISO / IEC 17025.Keywords: Mefenamic acid, validation method, UV spectrophotometryABSTRAK Pemeriksaan kadar zat aktif merupakan persyaratan yang harus dipenuhi untuk menjamin kualitas sediaan obat, untuk melakukan penetapan kadar zat aktif obat dibutuhkan suatu metode yang telah divalidasi. Validitas metode alternatif penetapan kadar asam mefenamat dalam ponsamic 500 mg tablet salut selaput (nama dagang) telah dilakukan. Metode penentuan kadar asam mefanat menggunakan spektrofotometri UV, sehingga ketersediaan alat HPLC yang terbatas dapat teratasi. Validitas metode alternatif diuji berdasarkan parameter akurasi dengan metode penambahan baku dan parameter ketelitian. Berdasarkan hasil diperoleh nilai linearitas adalah r sebesar 0,999 dan  persentase perbedaan metode spektrofotometri dengan metode HPLC (% Difference) sebesar 0,16%. Hasil penelitian menunjukkan metode alternatif penetapan kadar asam mefenamat dalam ponsamic 500 mg tablet salut selaput (nama dagang) menggunakan metode spektrofotometri, memenuhi syarat untuk diterima sesuai ISO/IEC 17025.Kata kunci : Asam mefenamat, Validasi metode, Spektrofotometri UV