Claim Missing Document
Check
Articles

Found 5 Documents
Search

ANALISA ORGANOLEPTIK DAN MIKROBIOLOGI AMDK DAN AMIU YANG DIJUAL SEKITAR KAMPUS UMKU Yunita Rusidah; Lailatul Farikhah
Jurnal READ (Research of Empowerment and Development) Vol 2 No 1 (2021): Maret 2021
Publisher : Pascasarjana Universitas Jenderal Soedirman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.read.2021.2.1.3975

Abstract

This study is intended to find the quality of bottled drinking water (AMDK) and drinking water (AMIU) sold around University of Muhammadiyah Kudus, in terms of organoleptic and microbiological parameters in drinking water according to SNI 01-3554-2006 and PMK No. 492 of 2010. The test is carried out using 10 sample of drinking water. They are 7 sample of AMDK (Ades, Airmu, Aqua, Cleo, Crystalin, Le mineral and Vit) and 3 sample of AMIU (Pasuruhan, Prambatan and Purwosari depots). The research consists of organoleptic and mikrobiologi (TPC, presence of E. coli and total coliform). The results of research shows that the organoleptik of all samples is in normal condition. Whereas, microbiologically, the TPC results before dilution were only Cleo and Ades which were suitable for consumption because they were absent from bacterial contamination. While the TPC results after dilution, testing the difference between E. Coli and Total coliform resulted in 7 samples of bottled drinking water which were safe and feasible as drinking water according to SNI 01-3553-2006 and 3 samples AMIU does not fulfil PMK No. 492/2010, as drinking water requirements.
Literature Study On The Diversity Of Coastal Echinoidea As A Source Of Biology Learning Materials For Biodiversity Yunita Rusidah; Lailatul Farikhah; Yayuk Mundriyastutik
Prosiding University Research Colloquium Proceeding of The 14th University Research Colloquium 2021: Bidang MIPA dan SOSHUM
Publisher : Konsorsium Lembaga Penelitian dan Pengabdian kepada Masyarakat Perguruan Tinggi Muhammadiyah 'Aisyiyah (PTMA) Koordinator Wilayah Jawa Tengah - DIY

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (392.937 KB)

Abstract

Penelitian ini bertujuan mengetahui kualitas air minum dalam kemasan (AMDK) dan airminum isi ulang (AMIU) yang dijual di sekitar kampus Universitas Muhammadiyah Kudus,ditinjau dari parameter fisik, kimia dan mikrobiologis pada air minum sesuai SNI 01-3554-2006 dan PMK no 492 tahun 2010. Pengujian dilakukan mengunakan 10 sampel air mineral,meliputi 7 AMDK (Ades, Airmu, Aqua, Cleo, Crystalin, Le mineral dan Vit) dan 3 sampelAMIU diambil dari depot air minum isi ulang disekitar kampus yaitu dari depot Pasuruhan,Prambatan dan Purwosari. Penelitian dilakukan di PT Sariguna Primatirta Kudus, yangmerupakan pabrik AMDK di kota Kudus, yang memiliki persyarataan pengujian AMDK.Pengujian yang dilakuan meliputi fisika kimia yang meliputi pengujian TDS, pH, dan tigaunsur logam berat yang meliputi pengujian kandungan unsur Fe, Mn dan Cl2 (klorin)danmikrobiologi yaitu TPC, keberaadaan E.coli dan Total Coliform.Hasil penelitian didiskripsikan bahwa hasil pengukuran fisika kimia terdiri dari kandungantotal dissolved solid (TDS) menghasilkan Airmu dan Cleo dibawah 10 ppm (demineral) dan 8sampel air mineral, hal ini sesuai dengan persyaratan TDS dari SNI yaitu > 10 ppm untukdemineral dan >500 ppm untuk air mineral. Pengujian pH berada pada pH normal berkisardiangka 7, dari 10 sampel hanya satu yang bernilai basa 8.37 yaitu sampel dari depotPasuruhan. Pengujian adanya logam berat Fe, Mn dalam kondisi baik, menunjukan angkanol dengan test kit merk merck. Sedangkan untuk pengujian adanya kandungan klorinmenunjukan hasil diatas ambang batas yaitu 0.05 ppm dari sampel air depot Pasuruhan,0.02 ppm dari depot Prambatan dan depot Purwosari. Hal ini tidak sesuai karena sesuaiketentuan SNI untuk kandungan klorin adalah 0 ppm. Hasil organoleptik dari 10 sampelmenghasilkan kondisi normal. Namun secara mikrobiologis hasil TPC sebelum pengeceranhanya Cleo dan Ades yang laik dikonsumsi karena aman dari kontaminasi bakteri.Sedangkan Hasil TPC setelah pengenceran, pengujian keberadaan E.Coli dan Total coliformmenghasilkan 7 sampel AMDK aman dan laik sebagai air minum sesuai SNI No.01-3553tahun 2006 dan 3 sample AIMU tidak memenuhi PMK no 492 tahun 2010, sebagaipersyaratan air minum.
Qualitative Analysis Of Bottled Drinking Water And Refilled Drinking Water Sold Around University Of Muhammadiyah Yunita Rusidah; Lailatul Farikhah; Yayuk Mundriyastutik
Prosiding University Research Colloquium Proceeding of The 14th University Research Colloquium 2021: Bidang MIPA dan SOSHUM
Publisher : Konsorsium Lembaga Penelitian dan Pengabdian kepada Masyarakat Perguruan Tinggi Muhammadiyah 'Aisyiyah (PTMA) Koordinator Wilayah Jawa Tengah - DIY

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (545.44 KB)

Abstract

This study aims to determine the quality of bottled drinking water and refilleddrinking water that sold around University of Muhammadiyah Kudus.It is in terms ofphysical, chemical, and microbiological parameters of drinking water based on SNI 01-3554-2006 and PMK no. 492 of 2010.The test was conducted byten samples of mineral water. Those are seven bottleddrinking water (Ades, Airmu, Aqua, Cleo, Crystalin, Le mineral and Vit) and three samplesof AMIU was taken from refill drinking water depots around campus, from depots inPasuruhan, Prambatan, and Purwosari. The research was conducted at PT SarigunaPrimatirta Kudus. It is a factory inKudus city which has testing requirements. The testscarried out chemical physics which included testing of TDS, pH, and three heavy metalelements and included testing of content of Fe, Mn and Cl2 (chlorine) elements, andmicrobiology namely TPC of presence of E-coli and Total Coliform.The results of physical and chemical measurements through total dissolved solid(TDS) showed that Airmu and Cleo under 10 ppm (demineral) and below 500 ppm for 8samples of mineral water.It is according to the TDS requirements of SNI, > 10 ppm fordemineralized and> 500 ppm for mineral water. The results of the pH test or the degree ofacidity are in normal pH which are around 7 of 9 samples and only one with an alkalinecondition is 8.37, namely sample from the Pasuruhan depot. The test for the presence ofheavy metals, Fe, Mn,is in good condition, showing the number zero with the brand testkit. In addition, for testing the presence of chlorine content, the results were above thethreshold, namely 0.05 ppm from the Pasuruhan depot water sample, 0.02 ppm from thePrambat depot and the Purwosari depot. This is not in accordance with SNI provisions forchlorine content of 0 ppm. Meanwhile, microbiologically of the TPC showed before dilutionwere only Cleo and Ades which were suitable for consumption because they were absentfrom bacterial contamination. While the TPC results after dilution, testing the differencebetween E-Coli and Total coliform resulted in 7 samples of bottled drinking water whichwere safe and feasible as drinking water according to SNI 01-3553-2006 and 3 samplesAMIU were not fulfilled to PMK No. 492/2010 as drinking water requirements.
Literature Study On The Diversity Of Coastal Echinoidea As A Source Of Biology Learning Materials For Biodiversity Yunita Rusidah; Lailatul Farikhah; Yayuk Mundriyastutik
Prosiding University Research Colloquium Proceeding of The 14th University Research Colloquium 2021: Bidang MIPA dan SOSHUM
Publisher : Konsorsium Lembaga Penelitian dan Pengabdian kepada Masyarakat Perguruan Tinggi Muhammadiyah 'Aisyiyah (PTMA) Koordinator Wilayah Jawa Tengah - DIY

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini bertujuan mengetahui kualitas air minum dalam kemasan (AMDK) dan airminum isi ulang (AMIU) yang dijual di sekitar kampus Universitas Muhammadiyah Kudus,ditinjau dari parameter fisik, kimia dan mikrobiologis pada air minum sesuai SNI 01-3554-2006 dan PMK no 492 tahun 2010. Pengujian dilakukan mengunakan 10 sampel air mineral,meliputi 7 AMDK (Ades, Airmu, Aqua, Cleo, Crystalin, Le mineral dan Vit) dan 3 sampelAMIU diambil dari depot air minum isi ulang disekitar kampus yaitu dari depot Pasuruhan,Prambatan dan Purwosari. Penelitian dilakukan di PT Sariguna Primatirta Kudus, yangmerupakan pabrik AMDK di kota Kudus, yang memiliki persyarataan pengujian AMDK.Pengujian yang dilakuan meliputi fisika kimia yang meliputi pengujian TDS, pH, dan tigaunsur logam berat yang meliputi pengujian kandungan unsur Fe, Mn dan Cl2 (klorin)danmikrobiologi yaitu TPC, keberaadaan E.coli dan Total Coliform.Hasil penelitian didiskripsikan bahwa hasil pengukuran fisika kimia terdiri dari kandungantotal dissolved solid (TDS) menghasilkan Airmu dan Cleo dibawah 10 ppm (demineral) dan 8sampel air mineral, hal ini sesuai dengan persyaratan TDS dari SNI yaitu > 10 ppm untukdemineral dan >500 ppm untuk air mineral. Pengujian pH berada pada pH normal berkisardiangka 7, dari 10 sampel hanya satu yang bernilai basa 8.37 yaitu sampel dari depotPasuruhan. Pengujian adanya logam berat Fe, Mn dalam kondisi baik, menunjukan angkanol dengan test kit merk merck. Sedangkan untuk pengujian adanya kandungan klorinmenunjukan hasil diatas ambang batas yaitu 0.05 ppm dari sampel air depot Pasuruhan,0.02 ppm dari depot Prambatan dan depot Purwosari. Hal ini tidak sesuai karena sesuaiketentuan SNI untuk kandungan klorin adalah 0 ppm. Hasil organoleptik dari 10 sampelmenghasilkan kondisi normal. Namun secara mikrobiologis hasil TPC sebelum pengeceranhanya Cleo dan Ades yang laik dikonsumsi karena aman dari kontaminasi bakteri.Sedangkan Hasil TPC setelah pengenceran, pengujian keberadaan E.Coli dan Total coliformmenghasilkan 7 sampel AMDK aman dan laik sebagai air minum sesuai SNI No.01-3553tahun 2006 dan 3 sample AIMU tidak memenuhi PMK no 492 tahun 2010, sebagaipersyaratan air minum.
Qualitative Analysis Of Bottled Drinking Water And Refilled Drinking Water Sold Around University Of Muhammadiyah Yunita Rusidah; Lailatul Farikhah; Yayuk Mundriyastutik
Prosiding University Research Colloquium Proceeding of The 14th University Research Colloquium 2021: Bidang MIPA dan SOSHUM
Publisher : Konsorsium Lembaga Penelitian dan Pengabdian kepada Masyarakat Perguruan Tinggi Muhammadiyah 'Aisyiyah (PTMA) Koordinator Wilayah Jawa Tengah - DIY

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study aims to determine the quality of bottled drinking water and refilleddrinking water that sold around University of Muhammadiyah Kudus.It is in terms ofphysical, chemical, and microbiological parameters of drinking water based on SNI 01-3554-2006 and PMK no. 492 of 2010.The test was conducted byten samples of mineral water. Those are seven bottleddrinking water (Ades, Airmu, Aqua, Cleo, Crystalin, Le mineral and Vit) and three samplesof AMIU was taken from refill drinking water depots around campus, from depots inPasuruhan, Prambatan, and Purwosari. The research was conducted at PT SarigunaPrimatirta Kudus. It is a factory inKudus city which has testing requirements. The testscarried out chemical physics which included testing of TDS, pH, and three heavy metalelements and included testing of content of Fe, Mn and Cl2 (chlorine) elements, andmicrobiology namely TPC of presence of E-coli and Total Coliform.The results of physical and chemical measurements through total dissolved solid(TDS) showed that Airmu and Cleo under 10 ppm (demineral) and below 500 ppm for 8samples of mineral water.It is according to the TDS requirements of SNI, > 10 ppm fordemineralized and> 500 ppm for mineral water. The results of the pH test or the degree ofacidity are in normal pH which are around 7 of 9 samples and only one with an alkalinecondition is 8.37, namely sample from the Pasuruhan depot. The test for the presence ofheavy metals, Fe, Mn,is in good condition, showing the number zero with the brand testkit. In addition, for testing the presence of chlorine content, the results were above thethreshold, namely 0.05 ppm from the Pasuruhan depot water sample, 0.02 ppm from thePrambat depot and the Purwosari depot. This is not in accordance with SNI provisions forchlorine content of 0 ppm. Meanwhile, microbiologically of the TPC showed before dilutionwere only Cleo and Ades which were suitable for consumption because they were absentfrom bacterial contamination. While the TPC results after dilution, testing the differencebetween E-Coli and Total coliform resulted in 7 samples of bottled drinking water whichwere safe and feasible as drinking water according to SNI 01-3553-2006 and 3 samplesAMIU were not fulfilled to PMK No. 492/2010 as drinking water requirements.