ANALISIS PELAKSANAAN STANDAR OPERATING PROCEDURE (SOP) PENGOLAHAN LIMBAH MEDIS DAN NON MEDIS DI RUMAH SAKIT JOGJA INTERNATIONAL HOSPITAL Widia Rahmatullah
JURNAL ILMU KESEHATAN BHAKTI SETYA MEDIKA Vol. 2 (2017): Jurnal Bhakti Setya Medika
Publisher : Politeknik Kesehatan Bhakti Setya Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (191.133 KB) | DOI: 10.56727/bsm.v2i.9

Abstract

Sampah dan limbah rumah sakit merupakan semua sampah yang dihasilkan oleh kegiatan rumah sakit. Secara umum sampah dan limbah rumah sakit terbagi menjadi dua yakni medis dan non medis. Pengelolaan dan pemisahan limbah rumah sakit harus dilakukan secara efektif sehingga tidak mencemari lingkungan, terutama untuk limbah medis harus dikelola dengan baik agar tidak menyebabkan masalah lingkungan. Pengelolaan limbah medis tidak boleh disamakan dengan limbah non medis. Hal tersebut akan memperbesar masalah limbah medis karena banyak mengandung mikroorganisme yang dapat menularkan penyakit. Penelitian ini dilakukan untuk memberikan informasi teknik pengolahan limbah medis dan non medis yang baik pada rumah sakit Jogja International Hospital dan untuk mengetahui pelaksanaan Standar Operational Prosedur pengolahan limbah dirumah sakit ini. Penelitian ini menggunakan metode deskriptif dengan menjelaskan proses pengolahan limbah di rumah sakit Jogja International Hospital. Berdasarkan hasil pengamatan bahwa pengolahan limbah medis dan non medis di Rumah Sakit JIH sudah sesuai dengan SOP yang ditetapkan dan mengikuti keputusan menteri nomor 1204 tahun 2004 tentang persyaratan lingkungan rumah sakit. Diharapkan informasi ini dapat mengatasi masalah pencemaran lingkungan khususnya limbah medis yang berasal dari limbah rumah sakit.
A AIR BACTERIA INDENTIFICATION BY USING GRAM STAINING: IDENTIFIKASI BAKTERI UDARA MENGGUNAKAN TEKNIK PEWARNAAN GRAM widia rahmatullah
JURNAL ILMU KESEHATAN BHAKTI SETYA MEDIKA Vol. 6 No. 2 (2021): Jurnal Ilmu Kesehatan Bhakti Setya Medika
Publisher : Politeknik Kesehatan Bhakti Setya Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (967.96 KB) | DOI: 10.56727/bsm.v6i2.62

Abstract

Blood processing is process in bloog service conducted in blood component room and it is possible that blood product get contamination. This research aimed at identifing the gram positive and gram negatifve bacteria which grow on culture medium Nutrient Agar (NA) and Mac Concay Agar (MCA). The research wa true experiment with post test only design whose result were descriptive. The sample of the research wa NA dan MCA media placed in 5 points at the blood component room of UDD PMI Yogyakarta bu using setting plate technique. It was found out that all the 10 petri dishes used as sample contained contamination in medium Nutrient Agar (NA) with result 20 % contained gram positve bacteria in the form of bacillus, 70 % contained gram positive bacteria in the form of coccus, 10 % contained gram positve bacteria in the form of bacillus and coccus, while 10 petri dishes used as sample containde contamination in medium Mac Concay Agar (NA) with result 60% contained gram negative bacteria in the form of bacillus, 30 % contained gram negative bacteria in the form of coccus, and 10 % contained gram negative bacteria in the form of bacillus and coccus.
IDENTIFIKASI KONTAMINASI BAKTERI PADA TENSIMETER DI RUANG PENYADAPAN DARAH (AFTAP) UDD PMI KOTA YOGYAKARTA widia rahmatullah
JURNAL ILMU KESEHATAN BHAKTI SETYA MEDIKA Vol. 7 No. 2 (2022): Jurnal Ilmu Kesehatan Bhakti Setya Medika
Publisher : Politeknik Kesehatan Bhakti Setya Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56727/bsm.v7i2.107

Abstract

Bacterial contamination that most often occurs is obtained from the environment, can be obtained from the process of taking blood, donors, the process of making components, equipment used and blood storage, and blood distribution. The results of bacterial contamination research found by Lutpiatina (2017) on medical stethoscopes showed that there were 21 (70%) samples of Staphylococcus aureus bacteria and 5 (17%) samples of Pseudomonas aeruginosa, while other bacteria were 4 (13%) samples. The purpose of this study was to determine the gram-positive and gram-negative bacteria that grew on Nutrient Agar (NA) and Mac Concay Agar (MCA) media on a sphygmomanometer in the blood tapping room (AFTAP) PMI Yogyakarta City. The research method used is True Experiment with The Posttest Only Design approach, namely the results of observations provide descriptive information. The results of the study of 30 samples resulted in bacterial growth with the details of 10 samples of Gram Positive cocus bacteria, 13 samples of Gram Negative bacilli and 7 samples of Gram Negative cocus bacteria. The conclusion of this study is that the most common bacteria found from the results of the swab on the sphygmomanometer in the blood tapping room (AFTAP) UTD PMI Yogyakarta City were Gram-negative bacteria with rod-shaped (Basil).