Dewi Megasari Juhrie
Department of Ophthalmology, Faculty of Medicine, Universitas Padjadjaran Cicendo National Eye Hospital, Bandung, West Java

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

The Accuracy Prediction of Cataract Surgery Refractive Results Using SRK/T and Haigis Formulas (with and without Personalized Constants) Dewi Megasari Juhrie; Mayasari Wahyu; Andrew M Knoch
Majalah Oftalmologi Indonesia Vol 42 No 3 (2016): Ophthalmologica Indonesiana
Publisher : The Indonesian Ophthalmologists Association (IOA, Perhimpunan Dokter Spesialis Mata Indonesia (Perdami))

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35749/journal.v42i3.104

Abstract

Background: Fourth generation of IOL calculation formula (Haigis formula) calculates the ACD which is important in determining the IOL position, so the calculation results expected to be more accurate than the previous generation formula. Haigis formula uses 3 constants that can be updated (optimal/personalized constants). This study aimed to compare the accuracy prediction of cataract surgery refractive results using SRK/T and Haigis formulas (with and without personalized constant).Methods: This is an analytic prospective comparative study. We used 198 medical records data to calculate the Haigis personalized constants. Keratobiometry examinations were performed to 23 eyes using the IOLMaster. The IOL power was calculated using 3 formulas. IOL power selected based on the Haigis formula calculation using personalized constants which gave the most closely result to plano. Best corrected subjective refraction and ME calculated 1 month after surgery.Results: The Haigis personalized constants for this study were a0 = -0.746, a1 = 0.184, and a2 = 0.208. The ME of SRK/T and Haigis formulas (with and without personalized constant) were -0.09±0.48 D, -0.13±0.36 D, and -0,18±0.37 D. ME percentage of SRK/T and Haigis formulas (with and without personalized constant) maximally reached at ±1.25 D, ±1.00 D, and ±1.25 D. Conclusion: The Haigis formula with personalized constants was more accurate than the Haigis formula without personalized constants in predicting the refractive result of cataract surgery. The accuracy of SRK/T formula is equal to the Haigis formula (with and without personalized constants).  Keywords: Haigis formula, SRK/T, personalized constants
The Accuracy Prediction of Cataract Surgery Refractive Results Using SRK/T and Haigis Formulas (with and without Personalized Constants) Dewi Megasari Juhrie; Mayasari Wahyu; Andrew M Knoch
Majalah Oftalmologi Indonesia Vol 42 No 3 (2016): Ophthalmologica Indonesiana
Publisher : The Indonesian Ophthalmologists Association (IOA, Perhimpunan Dokter Spesialis Mata Indonesia (Perdami))

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35749/journal.v42i3.104

Abstract

Background: Fourth generation of IOL calculation formula (Haigis formula) calculates the ACD which is important in determining the IOL position, so the calculation results expected to be more accurate than the previous generation formula. Haigis formula uses 3 constants that can be updated (optimal/personalized constants). This study aimed to compare the accuracy prediction of cataract surgery refractive results using SRK/T and Haigis formulas (with and without personalized constant).Methods: This is an analytic prospective comparative study. We used 198 medical records data to calculate the Haigis personalized constants. Keratobiometry examinations were performed to 23 eyes using the IOLMaster. The IOL power was calculated using 3 formulas. IOL power selected based on the Haigis formula calculation using personalized constants which gave the most closely result to plano. Best corrected subjective refraction and ME calculated 1 month after surgery.Results: The Haigis personalized constants for this study were a0 = -0.746, a1 = 0.184, and a2 = 0.208. The ME of SRK/T and Haigis formulas (with and without personalized constant) were -0.09±0.48 D, -0.13±0.36 D, and -0,18±0.37 D. ME percentage of SRK/T and Haigis formulas (with and without personalized constant) maximally reached at ±1.25 D, ±1.00 D, and ±1.25 D. Conclusion: The Haigis formula with personalized constants was more accurate than the Haigis formula without personalized constants in predicting the refractive result of cataract surgery. The accuracy of SRK/T formula is equal to the Haigis formula (with and without personalized constants).  Keywords: Haigis formula, SRK/T, personalized constants