Melisa
Department Of Prosthodontics Faculty Of Dentistry, Prof. Dr. Moestopo University Jakarta, Indonesia

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Treatment of Class I Kennedy lower jaw with precision attachment: Perawatan kasus Kelas I Kennedy rahang bawah dengan precision attachment Melisa; Laura Susanti Himawan
Makassar Dental Journal Vol. 10 No. 2 (2021): Volume 10 Issue 2 Agustus 2021
Publisher : Makassar Dental Journal PDGI Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35856/mdj.v10i2.428

Abstract

Background: Rehabilitation of Kennedy Class I edentulous involves a variety of treatment alternatives such as overdenture, metal frame removable partial denture, RPD with precision attachment and implants. The combination of RPD and fixed dent-ture using precision attachment or semi-precision is one of the best forms of RPD. Case: A 59-year-old male came to the RSGM FKG UI clinic. He wants to have new denture to eat more comfortable and improve his appearance. Management: Anamnesis, extra-oral and intra oral examinations, and panoramic x-ray were performed. After that, bridge was removed, periapical x-ray and definitive treatment was determined using metal frame RPD in upper jaw and RPD with precision attachment in lower jaw. Conclusion: Patient feels satisfied and comfortable with his dentures both in upper and lower jaw with precision attachments.
Replacement of porcelain fused to metal crown with e.max lithium disilicate crown (case report): Penggantian mahkota tiruan porcelain fused to metal dengan mahkota tiruan e.max lithium disilicate (laporan kasus) Melisa; TA Mahendra
Makassar Dental Journal Vol. 10 No. 3 (2021): Volume 10 Issue 3 Desember 2021
Publisher : Makassar Dental Journal PDGI Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35856/mdj.v10i3.454

Abstract

Background: Even though porcelain fused to metal (PFM) crown is the golden standard in dentistry, it still has a major disad-vantage, such as unaesthetic metallic seen. Resolving those type of problems, an all-ceramic restoration was chosen to improve aesthetic outcome especially in the anterior regions of the mouth. Objective: This article reports the replacement of old PFM crowns in central incisors with poor design with lithium disilicate crowns. Case: A 25-years-old female came to Prosthodontic Clinic RSKGM Universitas Indonesia with complaints of chipping PFM crowns in central incisors with poor shape and colour. Conclusion: Patient’s aesthetic expectations were successfully met through selection of lithium disilicate crowns.
Comparison of design of removable partial denture with conventional technique and computer-aided system: Perbandingan pembuatan desain gigi tiruan sebagian lepas dengan teknik konvensional dan sistem computer-aided Melisa
Makassar Dental Journal Vol. 11 No. 1 (2022): Volume 11 Issue 1 April 2022
Publisher : Makassar Dental Journal PDGI Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35856/mdj.v11i1.496

Abstract

In the last few decades, digital dentistry based on computer-aided design and computer-aided manufacturing (CAD/CAM) has been increasingly discussed. The use of CAD/CAM for the manufacture of fixed dentures shows a high success rate. Currently, CAD/CAM for the manufacture of removable partial dentures (RPD) has also been used in several studies. Several studies have been conducted to determine the level of accuracy and suitability of the manufacture of RPD made conventionally and CAD/ CAM systems, but there are still differences in results. Therefore, in this literature review, it will be discussed the comparison of the accuracy and suitability of conventionally made RPD and CAD/CAM systems.