APPLICATION OF INSTRUMENTATION AND CONTROL SYSTEM FOR BIOGAS POWER GENERATION COMMISSIONING AT PTPN V KAMPAR PALM OIL MILL Salehah, Nur Azimah; Prasetyo, Dwi Husodo; Senda, Semuel Pati; Supriyadi, Muhamad Rodhi; Adeliaa, Nesha; Samodra, Bayu; Adiprabowo, Arya Bhaskara; Muharto, Bambang; Anindita, Hana Nabila
Majalah Ilmiah Pengkajian Industri Vol 14, No 1 (2020): Majalah Ilmiah Pengkajian Industri
Publisher : BPPT

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29122/mipi.v14i1.3865

Abstract

Biogas Power Plant (PLT) from palm oil mill effluent had been commissioned by a team from the Center of Technology for the Energy Resources and Chemical Industry, Agency for the Assessment and Application of Technology (PTSEIK-BPPT). The biogas power plant is located in PTPN V Kampar, Riau Province. A PLC (Programmable Logic Controller) has been implemented to support the operation of biogas power plant. Proper sensor selection has been done for each measurement applications. A computer and mimic panel is used as an interface for the operation of PLC. The master control system communicates with the slave control systems and Human Machine Interface (HMI) by means of ethernet communication protocol. Commissioning phase is carried out for 2 hours with a load of 450 kW. Instrumentation and control system is able to measure important variables such as fluctuation in methane numbers, pressures, and biogas flow rate to check the suitability of biogas supply in accordance to gas engine specification.
APPLICATION OF TEMPERATURE CONTROL SYSTEMS AT THE CATALYST ACTIVATION STEP IN THE METHANOL TESTPLANT Adiprabowo, Arya Bhaskara; Pertiwi, Astri; Rahmawati, Nurdiah; Saputro, Frendy Rian; Valentino, Novio; Anindita, Hana Nabila; Septriana, Desy
Majalah Ilmiah Pengkajian Industri Vol. 15 No. 1 (2021): Majalah Ilmiah Pengkajian Industri
Publisher : Deputi TIRBR-BPPT

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Catalyst activation is an important step in methanol synthesis process, achieved by the reduction of CuO precursor producing Cu0 active sites.  Testplant’s temperature operation shall be maintainted at 220°C in order to maximize the CuO reduction process in the catalyst activation step. A temperature control system shall be applied in methanol testplant to maintain the temperature during reduction process, due to sensitivity of reduction process to temperature variation and possibility of disturbance such as change in gas flow rate which could affects the operating temperature. Temperature control systems are tested by using step response at the desired setpoint, which is 220°C at pre-heater and reactor and 60°C at sampling line. The tests are conducted by changing the setpoint value at temperature controller and previously stable flow gas in the system (disturbance rejection). The temperature control system proved to be able to response well during the test. In the end, methanol is produced from syngas, indicating catalyst activation success. Keywords: Catalyst Activation; Methanol Testplant; Temperature Controller