ANALISA PEMELIHARAAN ALAT SHORTWAVE DIATHERMY DI RUMAH SAKIT UMUM HERMINA MEDAN Afrin Nazar; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (240.03 KB)

Abstract

Shortwave Diathermy is one of the medical equipment that is a supporting aspect of the implementation of health service activities, and also really needs maintenance and supervision to avoid malfunctions. Shortwave Diathermy (SWD) is one of the therapeutic equipment and also a modality of heat with therapeutic application techniques using high-frequency radio electric currents by converting electromagnetic energy into heat energy. The purpose of this study was to determine the implementation of shortwave diathermy maintenance at Hermina General Hospital Medan. This research was conducted at General Hospital Hermina Medan Jl. Dormitory/Ampera II, Kec. Sei Sikambing C-II, Kec. Medan Helvetia by providing a questionnaire sheet containing questions/statements. The type of research used is a qualitative descriptive method conducted from June 2018. The results obtained from the respondents, from 24 questionnaires there were 23 questionnaires answered Yes and 1 questionnaire answered No. It was concluded that the implementation of the Shortwave Diathermy maintenance at Hermina General Hospital Medan was running properly, and was declared good.
ANALISA TIMER ALAT SHORTHWAVE DIATHERMY MEREK BTL 6000 Istiadi Ramadhan; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (205.441 KB)

Abstract

Shortwave Diathermy BTL 6000 is a therapy device that emits short waves that are used to warm up deep tissues and blood vessels. Shortwave Diathermy utilizes a certain frequency as a heat generator which is channeled into the patient's body tissues through electrodes and how does the time of therapy affect the heat of the body being treated. Research on Timer Analysis of the BTL 6000 Brand Shortwave Diathermy Tool was carried out using 3 time trials, then the timing was compared to the measuring instrument used, namely a stopwatch. The time settings used include 10 minutes, 20 minutes and 30 minutes. The BTL 6000 Brand Shortwave Diathermy Tool worked well, the device's Timer setting system worked well, and the stopwatch was used as a comparison tool for timer measurements. Timer setting with a time of 10 Minutes, there is a time difference of 12 seconds faster than the stopwatch, Frequency mode with output power of 50 Watt, frequency 300 Hz and Effect Power 6.0 Watt. , Continuous Mode with 20 Watt output power, and 20 Watt Effect Power, While on the timer setting with a time of 30 minutes, there is a difference in time of 9 seconds longer than the stopwatch, Continuous Mode with 20 Watt power output, and Effect Power 20 Watt, In this mode Continuous, the output of the tool has the same output, with output power = 20 Watts, medium effect Power = 20 Watts too
ANALISA KERJA BLOWER PADA ALAT VENTILATOR Putri Rizky Octaria Amazihono; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (183.472 KB)

Abstract

Ventilator is a mechanical aid that functions to provide breathing assistance so that patients breathe easier. this study aims to determine how the blower works in mixing oxygen and what is the rotational speed of the blower when mixing. This research was conducted by the integrated laboratory of USM-I. The research method used was descriptive with the from of quantitative survey implementation. Which aims to analyze the working principle of the blower on the ventolator. This research was conducted using a Hamilton C2 ventilator. in the blower flow measurement is done from the preassure setting points 5, 15, 25, 35, 55. The results of this study indicate that the blower works welol on the ventilator and the measurement results of each blower flow value reading does not exceed the predetermined standard limit of +-10%.
ANALISA PEMELIHARAAN PATIENT MONITOR di UPTD PUSKESMAS TELUK DALAM Ratahati Gaurifa; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 4 No 1 (2020): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (221.265 KB)

Abstract

"Analysis of Patient Monitor Maintenance at the UPTD public healty center Teluk dalam".Continuous health services need to be supported by equipment that is always ready to use and can function properly. This requires public healty center management to be able to manage and maintain medical equipment effectively and efficiently. This study aims to determine the implementation of patient monitor maintenance at the UPTD public healty center Teluk dalam. This research is a descriptive study with a quantitative survey method. The instrument used is to collect data. The results of this study indicate the aspects of natural resource input, processes, and outputs. The results of this study indicate that in practice, it cannot run properly, caused by limited technicians, lack of training, and maintenance SOP are not in accordance with procedures. It is recommended that the public healty center management pay more attention to the equipment maintenance system (input, process, and output) in order to avoid the problem of equipment damage and to work optimally.
ALUR KERJA ECG pada PASIEN MONITOR Hery Setiawan Gulo; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 4 No 1 (2020): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (465.236 KB)

Abstract

An electocardiogram (ECG) is one of the parameters in the patient monitor tool that is used to monitor the patient's physiological condition in the form of blood pressure, temperature, respiration, SpO2 and the shape of the heart pulse continuously. This study aims to determine the workflow of the ECG in monitor patients and to determine changes in the ECG waveform when the lead position is changed.This research was conducted at the USM-I Integrated Laboratory. The research method used was descriptive by observation. Which aims to find out how the ECG workflow on the patient monitor and to find out the changes in the ECG waveform when the lead position is changed.This research was conducted using the PM5000 patient monitor. The results of this study indicate that the electrical potential originating from the heart is detected on the surface of the body through electrodes and jelly, both of which are connected to the device via a patient cable in the form of a color coded lead on each lead, after amplifying then the electric pulse will be displayed on the display in the form wave. when installing the lead on the patient must be in accordance with the position and position according to the procedure, because it greatly affects the resulting wave.
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA Mhd. Rafli Perdana; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (205.885 KB)

Abstract

Medical devices are divices that are always in a ready to use condition and can function properly. This requires the Sari Mutiara University Integrated Laboratory to assist and medical equipment as effectively and efficiently as possible. This study aims to look at the syringe pump monitoring system in the USM-Indonesia Integrated Lab.Descriptive research method. Syringe pump tools and materials, questionnaire instruments used to conduct direct interviews with officers in the integrated laboratory, observation and documents.The results of this study indicate that all medical equipment including the syringe pump in the USM-Indonesia integrated Lab has never been maintained because there has not been a maintenance program for the medical equipment in the Lab. Integrated suggestions for syringe pump equipment and other health equipment to be maintained in the form of heating the appliance twice a week so that the tool is always in a condition that can function properly and has a longer service life, it is necessary to make SOP for operating the syringe pump tool and other tools.
ANALISA PRINSIP KERJA FLOW SENSOR DALAM MENGETAHUI VOLUME TIDAL MESIN ANASTESI VENTILATOR Kharisda Novtri Gratia Gulo; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (340.35 KB)

Abstract

Flow sensors have an important role in ventilator anesthesia machines, where flow sensors function to monitor air flow and pressure to obtain the amount of air volume and pressure delivered to the patient. If the volume of air entering the patient does not match the capacity of the patient's lungs, it can endanger the patient. So that a flow sensor is needed in order to know the accuracy of the volume that will be given to the patient.
ANALISA PEMELIHARAAN PATIENT MONITOR di UPTD PUSKESMAS TELUK DALAM Ratahati Gaurifa; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol. 4 No. 1 (2020): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v4i1.3236

Abstract

"Analysis of Patient Monitor Maintenance at the UPTD public healty center Teluk dalam".Continuous health services need to be supported by equipment that is always ready to use and can function properly. This requires public healty center management to be able to manage and maintain medical equipment effectively and efficiently. This study aims to determine the implementation of patient monitor maintenance at the UPTD public healty center Teluk dalam. This research is a descriptive study with a quantitative survey method. The instrument used is to collect data. The results of this study indicate the aspects of natural resource input, processes, and outputs. The results of this study indicate that in practice, it cannot run properly, caused by limited technicians, lack of training, and maintenance SOP are not in accordance with procedures. It is recommended that the public healty center management pay more attention to the equipment maintenance system (input, process, and output) in order to avoid the problem of equipment damage and to work optimally.
ALUR KERJA ECG pada PASIEN MONITOR Hery Setiawan Gulo; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol. 4 No. 1 (2020): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v4i1.3238

Abstract

An electocardiogram (ECG) is one of the parameters in the patient monitor tool that is used to monitor the patient's physiological condition in the form of blood pressure, temperature, respiration, SpO2 and the shape of the heart pulse continuously. This study aims to determine the workflow of the ECG in monitor patients and to determine changes in the ECG waveform when the lead position is changed.This research was conducted at the USM-I Integrated Laboratory. The research method used was descriptive by observation. Which aims to find out how the ECG workflow on the patient monitor and to find out the changes in the ECG waveform when the lead position is changed.This research was conducted using the PM5000 patient monitor. The results of this study indicate that the electrical potential originating from the heart is detected on the surface of the body through electrodes and jelly, both of which are connected to the device via a patient cable in the form of a color coded lead on each lead, after amplifying then the electric pulse will be displayed on the display in the form wave. when installing the lead on the patient must be in accordance with the position and position according to the procedure, because it greatly affects the resulting wave.
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA Mhd. Rafli Perdana; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol. 5 No. 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v5i1.3247

Abstract

Medical devices are divices that are always in a ready to use condition and can function properly. This requires the Sari Mutiara University Integrated Laboratory to assist and medical equipment as effectively and efficiently as possible. This study aims to look at the syringe pump monitoring system in the USM-Indonesia Integrated Lab.Descriptive research method. Syringe pump tools and materials, questionnaire instruments used to conduct direct interviews with officers in the integrated laboratory, observation and documents.The results of this study indicate that all medical equipment including the syringe pump in the USM-Indonesia integrated Lab has never been maintained because there has not been a maintenance program for the medical equipment in the Lab. Integrated suggestions for syringe pump equipment and other health equipment to be maintained in the form of heating the appliance twice a week so that the tool is always in a condition that can function properly and has a longer service life, it is necessary to make SOP for operating the syringe pump tool and other tools.