Comparison of two Wireless Electromyography Sensor Module Designs using wet electrodes and dry electrodes at the time of Sitting motion to stand Farid Amrinsani; Levana Forra Wakidi; Made Dwi Pandya Suryanta; Dessy Tri Wulandari; Wahyu Caesarendra
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.249

Abstract

One of the biosignals used to identify muscle signals in humans is electromyography. Electromyography signals are frequently utilized as input and are designed to aid in post-stroke therapy recovery or to assist people with disabilities. This phenomena has led to the development of numerous electromyography module sensor designs for use in support of various research-based applications. In this study, an electromyography sensor module without an electrode cable is compared to an electromyography sensor module that uses gel electrodes, plate electrodes, electrode cables, and other electrode technologies. A function generator is used to test each module, and the correlation value is sought to determine the connection between the two modules under consideration. Later, the findings of this study served as the foundation for other studies. Researchers also wish to explore the possibility of developing an electromyography sensor module by altering the wireless EMG sensor module's structure and design. Whereas this study can subsequently be extremely helpful to improve the standing of the Health Poltekkes Kemenkes Surabaya.
Detection Signal Electromyograpy using Dry Electrode and Disposible Electrodes on the Upper Extremity when Lifting Weights Farid Amrinsani; Levana Forra Wakidi; Made Dwi Pandya Suryanta; Dessy Tri Wulandari; Muhammad Tariq Sadiq
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.252

Abstract

One of the biosignals used to identify human muscle impulses is electromyography. Electromyographic signals are frequently utilized as inputs and are designed to help persons with disabilities or aid in the healing process following stroke therapy. According to studies, this occurrence has led to the development of numerous electromyography module sensor designs to meet different purposes. In this work, disposable electrodes and dry electrodes are used to examine the root mean square RMS values of two different electromyography sensor module types. With a 3 kg barber lift action, each module is used to detect signals in the biceps, which are part of the upper extremity muscles. According to the study's findings, the two electromyography modules with disposable electrodes produced data with a p-value of 0.001766368 0.05. It can be inferred that there is no difference between the E1 and E2 modules because the p-value for the t-test of the two modules with dry electrodes is 0.001766368 0.05. However, there is a variance in the amplitude's magnitude, with a difference of 30mV between the disposable and dry electrodes. The results of this study can be used to teach students, and a module developed as a result of it can be applied to other studies to help find electromyographic signals.