Goniometer Pintar Untuk Observasi Gerak Lutut Pasien Pasca Tindakan Fiksasi Ego Octabery; Putra Wisnu Agung Sucipto; Abdul Hafid Paronda
Jurnal Ilmiah Fisioterapi Vol 4 No 02 (2021): Agustus
Publisher : LPPM Universitas Abdurrab

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (908.706 KB) | DOI: 10.36341/jif.v4i02.1978

Abstract

Goniometers are made of a material shaped like a curved ruler. The indentation of this goniometer marks the degree of opening of the knee joint. This degree of knee opening gives a large RoM value. This goniometer with a ruler-like shape has drawbacks, the drawback lies in the accuracy of repeated measurements when performing knee openings, recording the patient's knee openings on a regular basis, the patient cannot perform therapy independently. To be able to overcome this situation, alternative technology can help, namely making a goniometer with three main features, namely measuring the orientation of the knee movement direction, measuring the orientation of the knee movement direction based on the MPU-6050 sensors and Arduino Nano. The MPU-6050 sensor is a sensor that is used as the main tool for measuring the Range of Motion (RoM) of the knee joint. exercise guide interface, which is a feature with a function as a virtual physiotherapist who will guide patients to perform exercise movements independently. And a data bank system, where this feature is used to store all medical history data in this physiotherapy process. The test results show that an electronic goniometer can be designed and built that can measure the angle of achievement of leg extension in Range of Motion (RoM) exercises without the need to measure manually using a goniometer ruler with a fairly good accuracy with an overall tool error value of 1.774%. and the biggest error is 2.75%. The exercise guide interface, especially on the knee motion picture, experienced an error when the angle opening exceeded 95° and the data bank managed to save the patient's angle opening data.
Teknologi Papan Keseimbangan Untuk Latihan Pengendalian Stabilitas Postural Tubuh Anak Arya Gilang Permana; Putra Wisnu Agung Sucipto; Seta Samsiana
Jurnal Ilmiah Fisioterapi Vol 5 No 01 (2022): Februari
Publisher : LPPM Universitas Abdurrab

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (528.672 KB) | DOI: 10.36341/jif.v5i01.2098

Abstract

On children , develop and repair condition motor is method best for realize balance postural. The method is with give a number of exercise which support strengthening performance muscle and coordination system sensory which complex . exercise this working for trigger movement psychomotor which emphasize on response physical in the form of movement body . To can support exercise balance body child , make it a technology which adopt principles in game child which used in stimulate movement psychomotor for control postural body . development technology done with method make a number of equipment , that is equipment technology game virtual and board balance electronic . From results design technology the succeed created a technology board balance for exercise control stability postural body child , which consist from board balance electronic and a game virtual as well as a data banking system capable keep history training . Based on results testing , tool this capable detect four direction motion tilt that is motion tilt forward , to the right , to the left and to the back . However tool this no can detect two direction tilt by together .