DEGREE OF CORRECTION IN BUNION USING DYNAMIC SPLINTS Zia Rehman; Osama Shahid
Journal of Prosthetics Orthotics and Science Technology Vol. 1 No. 1 (2022): JPOST: JOURNAL OF PROSTHETICS ORTHOTICS AND SCIENCE TECHNOLOGY
Publisher : POLITEKNIK KESEHATAN KEMENKES JAKARTA I

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (994.475 KB) | DOI: 10.36082/jpost.v1i1.653

Abstract

Background. Hallux valgus or bunions the most widely recognized issue of the forefoot in grown-ups (1). The deformity of Hallux valgus is reformist, and includes a few phases, yet starts with lateral deviation of the big toe (Hallux) and medially deviation of the first main metatarsal bone. An Hallux valgus angle more prominent than 15 degrees is viewed as unusual yet at such a point the proximal phalanx may in any case be consistent with the metatarsal head when seen on radiographs.(2) The cause of Hallux valgus has been a discuss topic for years, but is likely associated with genetic predisposition, restrictive footwear, other foot deformities such as pronation of the hind foot furthermore, (pes planus, hyper mobility, contracture of the Achilles ligament , and neuromuscular problems, for example, cerebral paralysis and stroke(3). Orthoses have been proposed to lessen the raised plantar weight under the medial ray in patients with Hallux Valgus or bunion and diminish pain (7,8) when joined with a toe separator, orthosis may likewise assist with remedying alignment. Preventing general disability and halting the progression of structural changes are important for the management of hallux valgus. Objectives. To evaluate the clinical effects of dynamic splints on Hallux valgus this study was performed. To measure the degree of correction that can be achieved using the dynamic splints. Methods. Sample size was 8. Hallux valgus patients with age from 15-60 years, Mild, moderate Hallux Valgus, Hallux valgus angle < 40 degree, Both genders. Results. Total sample size was 8, in which 6 (75%) were Female and 2 (25%) were males, and they all are from Peshawar. Total sample size was 8 and Mean of the angle before using the splint is (20.75) and standard deviation among the angle was (2.315). Total sample size was 8 and Mean of the angle after using appliance for 15 day was (19.88) and standard deviation of the total population was (2.58), while the correction achieved in degree of angle has a mean of (1.00) and standard deviation of (0.535). Data was recorded and analyzed through SPSS. Conclusion. The persistence of the effect of orthosis is another point which could be assessed by evaluating changes during the wash-out period. The fact is that the angular changes are related to the time when orthosis is worn, so these changes were returned to first state by doffing the orthosis.