Karakteristik Generator Sinkron 3 Phasa 0.3KW Dengan Rotor Kutub Bayangan Pada Beban Resistif, Induktif dan Kapasitif Wawan Gunawan
EPIC (Journal of Electrical Power Instrumentation and Control) Vol 6, No 1 (2023): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v6i1.30636

Abstract

Energi listrik dalam jumlah yang cukup dan dengan mutu yang baik merupakan kunci keberhasilan dan perkembangan yang pesat pada kegiatan-kegiatan industri. Hal tersebut telah menyumbang kemajuan ekonomi dan tingkat kesejahteraan masyarakat disetiap negara. Konversi energi mekanik menjadi energi listrik secara besar-besaran praktis dilakukan hanya dengan generator sinkron. Generator sinkron dapat dioperasikan sebagai mesin tunggal, akan tetapi biasanya generator akan terhubung dalam suatu sistem interkoneksi sehingga bekerja sejajar sinkron dengan alternator-alternator lain. Generator adalah sebuah mesin yang digunakan untuk mengubah energi mekanik yang dihasilkan oleh turbin menjadi energi listrik. Dalam desain generator sinkron, kadang terjadi fenomena dimana gelombang yang dihasilkan tidak sinus murni tetapi terjadi distorsi pada gelombang keluaran yang disebut tooth harmonics. Penelitian ini menganalisa penyebab terjadinya tooth harmonics yang terjadi pada generator sinkron 3 phasa dan unjuk kerja dari generator sinkron 0,3kW (synchronous machine) yang digerakkan oleh motor DC shunt sebagai penggerak (prime mover). Untuk mengatur kecepatan motor DC shunt digunakan CM Low Voltage 0 – 250-VDC dan untuk eksitasinya digunakan regulator DC stabilizer 240-V. Hasil pengujian diketahui bahwa pada generator sinkron dengan rotor kutub bayangan didapatkan hasil gelombang yang lebih baik. Adanya beban resistif tidak berpengaruh terhadap pembentukan gelombang keluaran generator sinkron sedangkan adanya beban kapasitif akan memperbaiki bentuk gelombang dan untuk beban induktif, bentuk gelombangnya akan menjadi lebih terdistorsi.
PENGARUH ARUS EKSITASI TERHADAP ARUS STATOR MOTOR SINKRON 3 FASA DENGAN VIRTUAL INSTRUMENT Anto Carmanto; Wawan Gunawan
Jurnal Informatika dan Teknik Elektro Terapan Vol 11, No 3 (2023)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v11i3.3322

Abstract

The three-phase current value of a synchronous motor has a great impact on its long-term reliability and performance under load. Therefore, maintenance and monitoring must be performed to determine the performance of synchronous motors. A virtual instrument and its LabView software can be used as a method to determine the operating current value of a synchronous motor. The device used in the study contains a synchronous motor as a load, and his LabView-equipped controller is used to execute commands during synchronous motor testing. NI MyDAQ is used as an input to the controller prior to using LabView, so it can be customized for use as an input to motors and controllers. Power is supplied by adjusting the motor input voltage to 380 volts and the controller input voltage to 220 volts. The purpose of the research is to develop tools and simulation software for synchronous motors that use voltage regulators to react to variations and determine minimum and maximum voltage values to determine motor performance. As a result of examination, the motor output reached a maximum current value of 0.4A at idle and a maximum controller current value.
PENATAAN INSTALASI LISTRIK RUMAH TAHFIDZ QURAN AN-NUR CIREBON JAWA BARAT Irawati Irawati; Ariyawan Sunardi; Wawan Gunawan; Deasy Kartikasari; Ria Gazali
SWADIMAS: JURNAL PENGABDIAN KEPADA MASYARAKAT Vol 2, No 1 (2024): SWADIMAS EDISI JANUARI 2024 (ON PROGRESS)
Publisher : Institut Teknologi dan Bisnis Swadharma

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56486/swadimas.vol2no1.414

Abstract

The community service was held at the An-Nur Quran memorization house in Cirebon, West Java. The target is to help the An-Nur Quran memorization house whose electrical installations are still not organized. If left unchecked, this can result in the children of the tahfiz quran house being easily exposed to electric shock, and there can be a short circuit of electricity, making it easy for a fire to occur. Based on the location survey and our observations in the field, the lighting installation in the local area is still not suitable for use. The current phenomenon of electrical installations is still not well considered by the community, so there are many fire disasters everywhere caused by short circuits. Due to the lack of knowledge of the community and the installer about electrical science and electrical installation requirements. Therefore, electrical installations need to be properly arranged following PUIL guidelines so that accidents caused by electricity can be avoided. The PKM implementation mechanism includes the stages of (1) Formation of an independent service team consisting of lecturers and students; (2) Site survey, consultation, and negotiation with the local government; (3) Deliberation in determining work patterns and programs; and (4) Preparation of tools and materials for service activities. The PKM activity resulted in the repair and arrangement of electrical installations at the An-Nur Quran memorization house in Cirebon, West Java, including lighting installations on the terrace of the Quran memorization house according to PUIL guidelines.Pengabdian Kepada Masyarakat yang diselenggarakan bertempat di rumah tahfidz quran An-Nur Cirebon Jawa Barat. Adapun sasarannya adalah untuk membantu Rumah tahfiz Quran An-Nur yang instalasi listriknya masih belum tertata rapi. Jika dibiarkan, hal ini dapat mengakibatkan anak-anak rumah tahfiz quran akan mudah terkena sengatan listrik, dan lebih dikhawatirkan lagi dapat terjadi hubung singkat aliran listrik, sehingga mudah terjadi kebakaran. Berdasarkan survei lokasi serta pengamatan kami di lapangan, instalasi lampu pada daerah setempat masih belum layak untuk digunakan. Fenomena saat ini instalasi listrik masih menjadi hal yang sepeleh bagi masyarakat, sehingga banyak terjadi bencana kebakaran dimana – mana yang disebabkan oleh hubungan singkat arus listrik. Hal ini di karenakan kurangnya pengetahuan masyarakat maupun pihak instalator mengenai ilmu kelistrikan dan persyaratan instalasi kelistrikan. Oleh karena itu, instalasi listrik perlu ditata dengan benar sesuai dengan pedoman PUIL agar peristiwa kecelakaan akibat listrik dapat dihindari. Mekanisme pelaksanaan PKM meliputi tahapan (1) Pembentukan tim pengabdian mandiri yang terdiri dari dosen dan mahasiswa; (2) Survei lokasi, konsultasi dan negoisasi dengan pemerintah setempat; (3) Musyawarah dalam menentukan pola dan program kerja; dan (4) Penyiapan alat dan bahan untuk kegiatan Pengabdian. Kegiatan PKM menghasilkan perbaikan dan penataan instalasi listrik di Rumah tahfiz quran An-Nur Cirebon Jawa Barat termasuk pemasangan instalasi penerangan teras rumah tahfiz quran sesuai pedoman PUIL
PENGARUH ARUS EKSITASI TERHADAP ARUS STATOR MOTOR SINKRON 3 FASA DENGAN VIRTUAL INSTRUMENT Anto Carmanto; Wawan Gunawan
Jurnal Informatika dan Teknik Elektro Terapan Vol 11, No 3 (2023)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v11i3.3322

Abstract

The three-phase current value of a synchronous motor has a great impact on its long-term reliability and performance under load. Therefore, maintenance and monitoring must be performed to determine the performance of synchronous motors. A virtual instrument and its LabView software can be used as a method to determine the operating current value of a synchronous motor. The device used in the study contains a synchronous motor as a load, and his LabView-equipped controller is used to execute commands during synchronous motor testing. NI MyDAQ is used as an input to the controller prior to using LabView, so it can be customized for use as an input to motors and controllers. Power is supplied by adjusting the motor input voltage to 380 volts and the controller input voltage to 220 volts. The purpose of the research is to develop tools and simulation software for synchronous motors that use voltage regulators to react to variations and determine minimum and maximum voltage values to determine motor performance. As a result of examination, the motor output reached a maximum current value of 0.4A at idle and a maximum controller current value.