One of the problems that occur in Indonesia is air pollution caused by the high intensity of citizen activity, especially most of which still use fossil-fueled motor vehicles to carry out their activities. The fossil fuel that is not burned perfectly can cause gas and particle pollution to form which can cause its amount to increase in the air and affect the environment. Therefore, measurement of motor vehicle emission tests based on low-cost sensors is conducted with CO, CO2, NO2, PM2.5, temperature, and humidity as its parameters. The usage of flow rate is addressed to the flow of the emission gas, which will be measured from an exhaust of a motor vehicle into the testing chamber and forwarded into the air for disposal. The flow rate used in this test ranges from 12-15 lpm. For that reason, the author performed the test for 10 minutes and got the average results of the measured parameters. The results are 1200 ppm for CO, 140000 ppm for CO2, and 80 °C for temperature (the show results are the average of the test results). The results shown are due to the small range of the low-cost sensor resulting in a huge difference.