BULETIN FISIKA
Vol 17 No 2 (2016): BULETIN FISIKA

APLIKASI KARBON GRAFIT UNTUK IMOBILISASI ION PB DALAM CAIRAN DENGAN METODE ELEKTROLISIS

Ni Wayan Sariasih (Udayana University)
Hery Suyanto (Udayana University)
Nyoman Wendri (Udayana University)



Article Info

Publish Date
01 Aug 2016

Abstract

This study aims to determine the lowest concentration of Pb element that can be immobilized by carbon graphite with electrolysis method. Electrolysis used carbon electrodes of graphite as the anode and cathode with current of 52.7 mA. The concentrations of Pb solution used in this research started from of 100 till 0.1 ppm. Pb element deposited on the cathode then irradiated by Nd - YAG laser ( 1064 nm, pulse width 7 ns ) of 100 mJ and its emission intensity of 405.78 nm was captured by the spectrometer HR 2500+, then the data plotted in intensity as a function of wavelength . The optimum data of charged for the electrolysis process was 80 coulomb and minimum concentration (limit of detection) of Pb that was capable immobilized by carbon graphite was 0,06 ppm.

Copyrights © 2016






Journal Info

Abbrev

buletinfisika

Publisher

Subject

Earth & Planetary Sciences Electrical & Electronics Engineering Environmental Science Materials Science & Nanotechnology Physics

Description

The Journal aims to promote the theory and application in the field of physics, and to encourage a vigorous dialogue between scholars and researchers all over the world. It presents original research articles, letters as well as review articles, publishes the latest achievements and developments in ...