PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID)
Vol. 1 No. 2 (2022): APRIL 2022

COMPARISON OF THE NUMBER OF ERYTHROCYTES IN 3 ML, 2 ML, & 1 ML OF BLOOD SAMPLES WITH K2EDTA ANTICOAGULANTS AFTER A 4-HOUR DELAY IN THE DR. H. ABDUL MOELOEK BANDAR LAMPUNG HOSPITAL

Syuhada (Departemen Patologi Klinik Unit Transfusi Darah Rumah Sakit Abdul Moeloek)
Hemas Priyayi (Program Studi Kedokteran, Fakultas Kedokteran, Universitas Malahayati)
Bella Tania Putri (Program Studi Kedokteran, Fakultas Kedokteran, Universitas Malahayati)
Zehan Aura Nabigha (Program Studi Kedokteran, Fakultas Kedokteran, Universitas Malahayati)
Tusy Triwahyuni (Departemen Parasitologi, Universitas Malahayati)



Article Info

Publish Date
24 Mar 2022

Abstract

Background: The volume of blood samples, especially the number of erythrocytes in laboratory examinations, has an important role in determining the results of the diagnosis, in this case pre-analytic errors often occur so that a definite diagnosis will be difficult to establish. Therefore, research on the comparison between the results of the examination of the number of erythrocytes in the volume of blood samples of 3 mL, 2 mL, and 1 mL after being delayed for 4 hours with K2EDTA anticoagulant helps to determine a definite diagnosis from laboratory tests, one of which is the count of the number of erythrocytes. Research purpose: it aims to identify the comparison of erythrocytes in the volume of blood sample 3 ml, 2 ml, and 1 ml with k2edta anticoagulant after postponed for four hours. Research methods: the study uses primary data with hematology analyzer in rsud Dr.abdul moeloek bandar lampung. This type of research is a quantitative, using observational analtic design with a cross sectional view and with consecutive method, through hematology analysis using a alayzer mindray bc-3600 hematology. The research has 50 respondents. Results: the results of erythrocytes comparison between blood volume 3 ml, 2 ml and 1 ml (ml) with k2edta anticoagulant after 4 hours have different results but statistically the results have the same with 3 ml, that show the lowest result. Conclusion: there is no significant differences between the examunation of the erythrocytes with the volume of blood sample 3 mL, 2 mL, and 1 mL in the vacutainer k2edta tube after postponed for four hours.

Copyrights © 2022






Journal Info

Abbrev

COMORBID

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Medicine & Pharmacology Neuroscience Nursing

Description

About the Journal PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID) is an international, modern, general medical publication that publishes research on all aspects of medicine, from fundamental research to significant clinical trials and cost-effectiveness analyses. We ...