Jurnal Teknik Sipil
Vol 23 No 2 (2016)

Analisa Keandalan Tampungan Waduk di Embung Tambak Pocok Bangkalan

Lily Montarcih Limantara (Jurusan Teknik Pengairan Fakultas Teknik Universitas Brawijaya Malang.)
Whima Regianto Putra (Jurusan Teknik Pengairan Fakultas Teknik Universitas Brawijaya Malang)



Article Info

Publish Date
01 Aug 2016

Abstract

Abstrak. Kebutuhan air domestik dihitung berdasarkan jumlah penduduk dan standar kebutuhan air di wilayah administratif yang akan dilayani. Untuk mengestimasi ketersediaan air dalam studi ini digunakan analisa debit Model NRECA dan F.J Mock. Untuk keperluan analisa keandalan tampungam, berdasarkan data debit hasil simulasi F.J Mock dan NRECA selama 20 tahun, dilakukan perpanjangan data debit dengan menggunakan metode Thomas-Fiering. Hasil simulasi keandalan embung dengan melakukan proses simulasi tiap data debit hasil bangkitan sepanjang 20 tahun dengan masa proyeksi selama 20 tahun dengan asumsi tidak ada perubahan parameter DAS, terdapat indikasi bahwa data debit untuk NRECA mengalami kegagalan pada debit tahun 2004, terjadi peluang keandalan 100% pada tahun 2007, dan 25% pada tahun 2026. Sedangkan untuk data debit hasil dari F.J Mock, peluang keandalan 100% terjadi pada tahun 2007 sampai dengan tahun 2026 untuk semua simulasi data debit. Dikarenakan tidak adanya data debit di lapangan, maka pemilihan data debit dilakukan dengan mengambil Qmin untuk masingmasing data debit. Dari 2 metode tsb didapatkan untuk Qmin hasil dari F.J Mock embung memiliki tingkat keandalan 100% pada tahun 2007 sampai dengan 2026, sedangkan untuk Qmin NRECA embung hanya mampu melayani seluruh penduduk (100%) pada tahun 2007, sedangkan untuk tahun-tahun berikutnya mengalami penurunan hingga 25% pada tahun 2026.Abstract. Domestic water demand is analyzed based on the number of population and the standard of water demand in served administrative region. To estimate the water supply, this study used the models of NRECA and F.J. Mock. For analyzing reservoir reliability based on the simulation discharge result of F.J. Mock and NRECA during 20 years there was needed discharge data generated by using Thomas Fiering method. Simulation result of small-dam reliability by carrying out the simulation process every discharge data of generated result along 20 years with the projection during 20 years indicated that discharge result of NRECA was failure in 2004 and it assumes that there is no parameter change in catchment, it had the possibility of reliability on 100% in 2007 and 25% in 2026.  however, discharge result of F.J. Mock had the possibility of reliability on 100% and it was happened in 2007, and 25% in 2026 for the whole simulation of discharge. There was no discharge data in study location, so minimum discharge was the optional one. Based on the two methods, the Qmin of F.J. Mock has the reliability level of 100% in 2007 until 2026. However Qmin of NRECA has only the ability to serve the whole population (100%) in 2007 but for the next years there was decreasing until 25% in 2026.

Copyrights © 2016






Journal Info

Abbrev

JTS

Publisher

Subject

Civil Engineering, Building, Construction & Architecture

Description

Jurnal Teknik Sipil merupakan jurnal ilmiah yang diterbitkan berkala setiap tiga bulan, yaitu April, Agustus dan Desember. Jurnal Teknik Sipil diterbitkan untuk pertama kalinya pada tahun 1990 dengan membawa misi sebagai pelopor dalam penerbitan media informasi perkembangan ilmu Teknik Sipil di ...