International Journal of Advanced Health Science and Technology
Vol. 2 No. 4 (2022): August

Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor

Yudistira Marsya Puvindra (Electrical Engineering Study Program, Universitas Islam Sultan Agung, Semarang, 50112, Indonesia)
Arief Marwanto (Electrical Engineering Study Program, Universitas Islam Sultan Agung, Semarang)
Eka Nuryanto Budisusila (Unknown)
Vugar Abdullayev (Azerbaijan State Oil and Industry University, Azerbaijan)



Article Info

Publish Date
25 Aug 2022

Abstract

Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch. This makes the setting is subjective and cannot be shown with numbers. In addition, nurses cannot monitor the infusion rate continuously. Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously. This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops. For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly. And for the display uses a OLED display and a buzzer as an indicator. The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly. This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume. This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc). The accuracy of volume readings ranges from 95-99% for the macro drip and 94.5-97% with the micro drip. And for speed accuracy ranges from 92.37-98.46%. Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator. This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer. With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.

Copyrights © 2022






Journal Info

Abbrev

ijahst

Publisher

Subject

Electrical & Electronics Engineering Health Professions Nursing Public Health

Description

International Journal of Advanced Health Science and Technology (IJAHST) publishes peer-reviewed, original research and review articles in an open-access format. Accepted articles span the full extent of the Public Health, Environmental Health, Nursing, Oral and Dental Health, Midwifery, Nutrition, ...