ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika
Vol 11, No 1 (2023): ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektr

Prototype of Portable Heart Monitoring System using BITalino

ERWIN SITOMPUL (President University)
ANTONIUS SUHARTOMO (President University)
FARHAN DARMAWAN (Universitas Padjajaran)
NENDI SUHENDI SYAFEI (Universitas Padjajaran)
ARJON TURNIP (Universitas Padjajaran)



Article Info

Publish Date
24 Jan 2023

Abstract

ABSTRAKJantung adalah organ vital yang menuntut perhatian khusus, terutama untuk orang dengan resiko serangan jantung. Bagi orang kategori ini, diperlukan detektor detak jantung yang bekerja secara kontinu dan real-time yang dapat mendeteksi adanya gangguan jantung secara dini. Pada penelitian ini, penulis mengajukan prototipe sistem monitoring jantung portable (PSMJP) dengan menggunakan modul bio-signal BITalino. Hasil pengukuran diproses pada perangkat komputer yang terhubung dengan BITalino melalui transmisi Bluetooth. Suatu program pemroses sinyal dirancang dengan menggunakan Algorithma Hamilton. Tingkat keberhasilan deteksi pada pengujian terhadap sampel EKG mentah dan pengukuran EKG mentah adalah 100%. PSMJP diujikan kepada 15 naracoba untuk kondisi duduk dan kondisi berjalan. PSMJP berfungsi baik pada 29 dari 30 pengukuran, dimana sinyal elektrik dari jantung terbukti dapat diproses dan memberikan hasil akhir berupa fitur-fitur gelombang detak jantung dan laju detak jantung.Kata kunci: denyut jantung, algoritma Hamilton, BITalino, EKG ABSTRACTThe heart is a vital organ that requires special attention, especially for people with heart attack risk. For people of this category, a heart rate detector that works continuously and in real-time is needed so that heart problems can be detected. In this study, the authors proposed a prototype of a portable heart monitoring system (PPHMS) using the BITalino bio-signal module. The measurement results are processed on a computer device connected to BITalino via Bluetooth transmission. A signal processing program was designed using Hamilton Algorithm. The detection success rate on testing for a raw ECG sample and raw ECG measurement was 100 %. PPHMS was tested on 15 subjects for sitting conditions and walking conditions. PPHMS works well in 29 of the 30 measurements, where electrical signals from the heart are proven to be successfully processed. The final results in the form of heart wave features and heart rate can be provided.Keywords: heart rate, Hamilton Algorithm, BITalino, ECG

Copyrights © 2023






Journal Info

Abbrev

elkomika

Publisher

Subject

Electrical & Electronics Engineering Engineering

Description

Jurnal ELKOMIKA diterbitkan 3 (tiga) kali dalam satu tahun pada bulan Januari, Mei dan September. Jurnal ini berisi tulisan yang diangkat dari hasil penelitian dan kajian analisis di bidang ilmu pengetahuan dan teknologi, khususnya pada Teknik Energi Elektrik, Teknik Telekomunikasi, dan Teknik ...