IJRETINA - International Journal of Retina
Vol 2 No 2 (2019): International Journal of Retina (IJRetina) - INAVRS

CONDENSING LENS ON BINOCULAR INDIRECT OPHTHALMOSCOPY AND SLIT-LAMP BIOMICROSCOPY

Danang Yoga Wiguna (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)
Sauli Ari Widjaja (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)
Wimbo Sasono (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)
Muhammad Firmansjah (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)
Ima Yustiarini (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)
Ady Dwi Prakosa (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)
Moestidjab Moestidjab (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)
Gatut Suhendro (Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital Surabaya, Indonesia)



Article Info

Publish Date
18 Sep 2019

Abstract

Condensing lens is a lens used as an auxiliary lens in indirect instruments to examines the fundus. This lens is used with binocular indirect ophthalmoscope and slit-lamp biomicroscope to reach a stereopsis image of fundus. Optical principle of condensing lens is to make the eye in myopic condition, so it can producesa real, aerial, inverted and reversed image. This lens was placed between the instruments and the eye of the patient which located closer to patient’s eye. Optimalized position of the lens can produce a good fundus image. Condensing lens have so many power of dioptre that each power produces different magnification and field of view. High powered lenses produces wider field of view than low powered ones. High powered lens can also used in patient with small dilated pupil and shorter distance of examination. Low powered lenses offer more magnification. Fundus examination with binocular indirect ophthalmoscope and slit-lamp biomicroscope have purpose to produces stereopsis image because of the binocularity system. These two instruments have each advantages and disadvantages. The advantages of binocular indirect ophthalmoscope are a portable instrument, relatively can be used in uncooperative patient and it can be used with scleral indentation to reach more peripheral view of the fundus. Meanwhile slit-lamp biomicroscope has the advantages to offer more magnification and flexible illumination system. With higher powered lens use in biomicroscope, it also give advantages in shorter distance of examination and wider field of view.

Copyrights © 2019






Journal Info

Abbrev

ijretina

Publisher

Subject

Health Professions Medicine & Pharmacology Public Health

Description

International Journal of Retina is an open access journal, accepting article in English language from all over the worlds. The aims is to provide international researchers, doctors, and clinicians in the basic and clinical fields of ophthalmology, especially retina to publish the original article, ...