Abstract

The most widely used refrigeration machine today is a refrigeration machine that operates with a vapor compression cycle (SKU). To operate a vapor compression machine, refrigerant is needed as a working fluid. The most widely used refrigerants are chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants. However, their use can damage the ozone layer and has a great potential to increase the effects of global warming. Therefore, a refrigeration system that is environmentally friendly and also has low power is needed, this can be fulfilled by using thermoelectric. This research was conducted to analyze the performance of temperature differences, heat absorbed, cooling capacity and COP in thermoelectric-based cooler boxes, thermoelectric performance with variations in input voltage and with variations in the addition of heatsinks where the method used is experimental by controlling the variable input voltage. From the research results, the calorific value absorbed is proportional to the increase in the applied voltage. Where the greater the voltage applied, the heat absorbed will be higher and the input power that enters the thermoelectric module is directly proportional to the incoming voltage where the greater the voltage. Then the power that goes into the thermoelectric will also be even greater. Whereas the COP value will decrease as the voltage increases and the best thermoelectric performance is with a voltage of 10 V. This can be seen after 60 minutes, the temperature difference value is 6.6 0K, the absorbed calorific value is 19,150 W, and the COP is 0.921. The thermoelectric performance is not only based on the COP value but also based on a review of the electric power consumed and the cooling speed during the 60 minute test. Then for the addition of a copper heatsink the COP value is 0.4832 and the temperature drop in the cooler box is only 3.9 0K, the value is lower than without the additional heatsink due to the gap between the aluminum heatsinks.

Copyrights © 2023






Journal Info

Abbrev

IJST

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering

Description

International Journal Science and Technology (IJST) is a scientific journal that presents original articles about research knowledge and information or the latest research and development applications in the field of technology. The scope of the IJST Journal covers the fields of Informatics, ...