Paediatrica Indonesiana
Vol 56 No 5 (2016): September 2016

Comparison of ventilation parameters and blood gas analysis in mechanically-ventilated children who received chest physiotherapy and suctioning vs. suctioning alone

Monalisa Elizabeth (Department of Child Health, University of Sumatera Utara Medical School/H. Adam Malik General Hospital, Medan, North Sumatera)
Chairul Yoel (Department of Child Health, University of Sumatera Utara Medical School/H. Adam Malik General Hospital, Medan, North Sumatera)
Muhammad Ali (Department of Child Health, University of Sumatera Utara Medical School/H. Adam Malik General Hospital, Medan, North Sumatera)
M. Sjabroeddin Loebis (Department of Child Health, University of Sumatera Utara Medical School/H. Adam Malik General Hospital, Medan, North Sumatera)
Hasanul Arifin (Department of Child Health, University of Sumatera Utara Medical School/H. Adam Malik General Hospital, Medan, North Sumatera)
Pertin Sianturi (Department of Child Health, University of Sumatera Utara Medical School/H. Adam Malik General Hospital, Medan, North Sumatera)



Article Info

Publish Date
09 Jan 2017

Abstract

Background Chest physiotherapy and suctioning are routine methods for airway clearance in mechanically-ventilated children. However, chest physiotherapy has not been confirmed to affect ventilation parameters, such as tidal volume (TV), peak inflation pressure (PIP), peak inspiratory flow (PIF), and peak expiratory flow (PEF), as well as blood gas analysis (BGA) values in pediatric intensive care unit (PICU) patients.Objective To determine the efficacy of chest physiotherapy and suctioning vs. suctioning alone for improving the mechanical ventilation parameters and BGA.Methods This randomized, single-blind, clinical trial was conducted from November 2012 to June 2013 in the PICU at Haji Adam Malik Hospital, Medan. A total of 40 mechanically-ventilated pediatric patients were enrolled and divided into either the chest physiotherapy and suctioning group (24 subjects) or the suctioning alone group (16 subjects). Subjects underwent treatment, followed by monitoring of their ventilation parameters and blood gas analyses. Data were analyzed by independent t-test and Mann-Whitney test.Results Subjects comprised of 23 boys and 17 girls, with an age range of 1–204 months. After the respective treatments (chest physiotherapy and suctioning vs. suctioning alone), the ventilation parameters were as follows: median TV (60.0 vs. 56.5 mL, respectively; P=0.838), median PEF (10.4 vs. 10.8 I/s, respectively; P=0.838), median PIF (7.4 vs. 8.2 I/s, respectively; P=0.469), and mean PIP (17.3 vs. 15.6 cmH2O, respectively; P=0.23). The BGA values were: median pH (7.4 vs. 7.3, respectively; P=0.838), median pCO2 (38.4 vs. 36.2 mmHg, respectively; P=1.000), mean pO2 (136.6 vs. 139.2 mmHg, respectively; P=0.834), median HCO3 (20.4 vs. 22.7 mmol/L, respectively; P=0.594), median TCO2 (22.0 vs. 23.7 mmol/L, respectively; P=0.672), mean BE (-4.3 vs. -3.1 mmol/L, respectively; P=0.629), and median O2 saturation  (98.5 vs. 98.3 %, respectively; P=0.967).Conclusion In mechanically-ventilated children in the PICU, ventilation parameters and BGA values are not significantly different between subjects who received both chest physiotherapy and suctioning and those who received suctioning alone.

Copyrights © 2016






Journal Info

Abbrev

paediatrica-indonesiana

Publisher

Subject

Health Professions Medicine & Pharmacology

Description

Paediatrica Indonesiana is a medical journal devoted to the health, in a broad sense, affecting fetuses, infants, children, and adolescents, belonged to the Indonesian Pediatric Society. Its publications are directed to pediatricians and other medical practitioners or researchers at all levels of ...