cover
Contact Name
HENNY SYAPITRI
Contact Email
ojs.usmindonesia19@gmail.com
Phone
+6285370854773
Journal Mail Official
fitri.apriyulida@yahoo.com
Editorial Address
Jln. Kapten Muslim No.79 Medan
Location
Kota medan,
Sumatera utara
INDONESIA
Jurnal Mutiara Elektromedik
ISSN : ""     EISSN : 26147963     DOI : https://doi.org/10.51544/elektromedik.v6i1
Core Subject : Engineering,
Focus : Jurnal Mutiara Elektromedik yang memuat hasil penelitian tentang kajian keilmuan Teknologi Elektromedik Scope : Teknologi Elektromedik, Teknik Elektro, Teknologi Radiologi Pencitraan, Teknologi Instrumentasi, Fisika medis, Rekam Medis dan Sistem Informasi Kesehatan
Articles 10 Documents
Search results for , issue "Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik" : 10 Documents clear
ANALISIS KALIBRASI SUHU DAN KEBISINGAN PADA INKUBATOR PERAWATAN MENGGUNAKAN METODE ECRI Zulfahmi Zulfahmi; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (411.996 KB)

Abstract

Incubator is a very important tool in hospitals, especially for premature babies. Because this tool is very related to the safety and survival of the baby, periodic calibration is needed. The purpose of this research is to find out the calibration techniques and the calculation of uncertainty of the data resulting from temperature and noise measurements. The incubator calibration activity refers to the ECRI method 415-20010301-01. As the determination of the threshold value or test passing value is +- 1C for temperature and <-65 dBA for noise. The results obtained from the calibration and calculation are 31.89 +- 0.48 C for temperature and 44.7 +- 7.2 dBA for noise. From these results it was stated that the CHS-i1000 incubator was declared suitable for use.
ANALISIS ALUR KERJA SPO2 PADA ALAT PATIENT MONITOR Abdul Haris Al Baihaki; Khairil Abdillah
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (267.924 KB)

Abstract

Oxygen saturation(Sp) is one of the parameters in the patient's device The monitor is used as a measurement of oxygen levels in the blood Non-invasive measurements whose results are directly displayed on LCD. Measurement of oxygen levels in the blood using this device is equivalent by using measurement using pulse oxymetry. Aim research to find out the Sp workflow on patient monitoring devices, research held on July- August, 2018 at Sari Hospital Mutiara medan, the study was carried out on the device Patient Monitor brand L-Gemedical system, type-CF generated Sp waveform is the Sp value and the limit larm, the input of this system is the LED sensor and Photodioda which produces the light transmission process on the finger and the results of the measurement tool will be displayed on the display screen in the form of a number value.
ANALISIS PENGARUH FOCUS FILM DISTANCE PADA PESAWAT RONTGEN GENERAL PURPOSE Setia Gunawan Mendropa; Samser Nababan
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (272.868 KB)

Abstract

Analysis of the influence of Distance film focus (FFD) on general purpose X-ray on variations of 80 cm, 100 cm and 120 cm FFD using Allignment Beam with a height of 15 cm and collimator test tool as the object of research at the Radiology Installation of Amanda Brastagi General Hospital. The aim is to determine and analyze the accuracy of the center point of the X-ray beam and the density of radiographic films. To diagnose, X-ray diagnostics of this unit must be precise and accurate in determining the location or place of interference in the human body. So we need to test the accuracy of the center point of the X-ray beam, so that the output of the X-ray beam from X-ray tube to the patient is still in parallel and there is no shift in angle or distance on the X-ray tube.After research and analysis, angular deviations are produced which are still within the predetermined tolerance limit of 3my.
ANALISA PEMELIHARAAN ALAT SHORTWAVE DIATHERMY DI RUMAH SAKIT UMUM HERMINA MEDAN Afrin Nazar; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (240.03 KB)

Abstract

Shortwave Diathermy is one of the medical equipment that is a supporting aspect of the implementation of health service activities, and also really needs maintenance and supervision to avoid malfunctions. Shortwave Diathermy (SWD) is one of the therapeutic equipment and also a modality of heat with therapeutic application techniques using high-frequency radio electric currents by converting electromagnetic energy into heat energy. The purpose of this study was to determine the implementation of shortwave diathermy maintenance at Hermina General Hospital Medan. This research was conducted at General Hospital Hermina Medan Jl. Dormitory/Ampera II, Kec. Sei Sikambing C-II, Kec. Medan Helvetia by providing a questionnaire sheet containing questions/statements. The type of research used is a qualitative descriptive method conducted from June 2018. The results obtained from the respondents, from 24 questionnaires there were 23 questionnaires answered Yes and 1 questionnaire answered No. It was concluded that the implementation of the Shortwave Diathermy maintenance at Hermina General Hospital Medan was running properly, and was declared good.
ANALISIS KALIBRASI CENTRIFUGES MENGGUNAKAN METODE ECRI 456-0595 Zainal Abidin Siregar; Yulizham Yulizham
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (294.375 KB)

Abstract

Health equipment is a supporting tool for medical services. Health services tha are well sipported by equipment that is good, safe, and in accordance with its function so that there is no error in the patient's diagnosis. Calibration is aseries of actovities that form a relationship between the value indicated bt a measuring instrument system, or a values represented by a measuring material, with known value that are related to the magnitude measured in certain conditon.
RANCANG BANGUN TIMER KONTROL ALAT LAMPU ULTRA VIOLET STERILIZER DILENGKAPI SISTEM BUZZER Novriani Romaulina Saragih; Rizaldi Ibrahim
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (378.632 KB)

Abstract

Ultraviolet lamp sterilizer is a hospital operating room sterilizer to avoid spore living species, as well as contaminated bacterial viruses from outside where by utilizing S. ultraviolet light type. Planning of this tool aims to obtain a design timer for ultraviolet lamp sterilizer equipped with a system ATMega8535 microcontroller based buzzer uses PIR sensor as an indicator of detecting objects in the operating room. Where this research begins with gathering resources, formulating problems, designing tools, designing tools, and performing function tests. After the device has been designed, the function test is performed for each circuit in the tool to work properly, where by measuring each circuit on the device to find out whether the device works according to a good system where by measuring power supply voltage, PIR sensor, ultraviolet lamp, relay, and buzzer.
ANALISA TIMER ALAT SHORTHWAVE DIATHERMY MEREK BTL 6000 Istiadi Ramadhan; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (205.441 KB)

Abstract

Shortwave Diathermy BTL 6000 is a therapy device that emits short waves that are used to warm up deep tissues and blood vessels. Shortwave Diathermy utilizes a certain frequency as a heat generator which is channeled into the patient's body tissues through electrodes and how does the time of therapy affect the heat of the body being treated. Research on Timer Analysis of the BTL 6000 Brand Shortwave Diathermy Tool was carried out using 3 time trials, then the timing was compared to the measuring instrument used, namely a stopwatch. The time settings used include 10 minutes, 20 minutes and 30 minutes. The BTL 6000 Brand Shortwave Diathermy Tool worked well, the device's Timer setting system worked well, and the stopwatch was used as a comparison tool for timer measurements. Timer setting with a time of 10 Minutes, there is a time difference of 12 seconds faster than the stopwatch, Frequency mode with output power of 50 Watt, frequency 300 Hz and Effect Power 6.0 Watt. , Continuous Mode with 20 Watt output power, and 20 Watt Effect Power, While on the timer setting with a time of 30 minutes, there is a difference in time of 9 seconds longer than the stopwatch, Continuous Mode with 20 Watt power output, and Effect Power 20 Watt, In this mode Continuous, the output of the tool has the same output, with output power = 20 Watts, medium effect Power = 20 Watts too
ANALISA PEMELIHARAAN INFANT WARMER DI RUMAH SAKIT UMUM SARAH MEDAN M. Wahid Afdillah; Dzia Ur Ridha
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (276.064 KB) | DOI: 10.51544/elektromedik.v2i1.3222

Abstract

Infant warmer is one of the live support and saving tools that is used to provide comfort and warmth to newborns, where the baby needs a temperature that is in accordance with the temperature in the mother's womb, which is between 34 °C - 37 °C. The purpose of this study was to determine the implementation of the maintenance of the Infant Warmer at Sarah General Hospital Medan. This research was conducted at Sarah General Hospital Medan Jl. Baja Raya No.10, Kec. Medan Baru by distributing questionnaires containing questions/statements. The type of research used is a descriptive method which was carried out from January 2018. The results obtained from the respondents, from 22 questionnaires there were 21 questionnaires answered Yes and 1 questionnaire answered No. It was concluded that the implementation of the maintenance of the Infant Warmer at Sarah Medan General Hospital was running properly, and was declared good.
ANALISA KERJA BLOWER PADA ALAT VENTILATOR Putri Rizky Octaria Amazihono; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (183.472 KB)

Abstract

Ventilator is a mechanical aid that functions to provide breathing assistance so that patients breathe easier. this study aims to determine how the blower works in mixing oxygen and what is the rotational speed of the blower when mixing. This research was conducted by the integrated laboratory of USM-I. The research method used was descriptive with the from of quantitative survey implementation. Which aims to analyze the working principle of the blower on the ventolator. This research was conducted using a Hamilton C2 ventilator. in the blower flow measurement is done from the preassure setting points 5, 15, 25, 35, 55. The results of this study indicate that the blower works welol on the ventilator and the measurement results of each blower flow value reading does not exceed the predetermined standard limit of +-10%.
RANCANG BANGUN SISTEM TEMPERATUR DAN MONITORING TIMER PADA AUTOCLAVE BERBASIS MIKROKONTROLLER ATMega 8535 Santa Lusi Sitohang; Fitria Priyulida
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (729.976 KB)

Abstract

Autoclave is heating tool and is used to sterilize things by using high pressure and high temperature steam 121C for about 15 minutes. The purpose of this tool is to kill endospores, resistant cell produced by bacteria. This cell is resistant against heat, dehydration and antibiotic. Research has been done for the design of time controlling and monitoring system at Autoclave based on microcontroller ATMega 8535. The purpose of this research is to produce Autoclave equipped with temperature controller and time monitoring which is beneficial to save energy and time using Autoclave. This tool is also equipped with circuit to detect problem. In this research, the tool’s operational system has been programmed with Thormocouple sensory system, Water Level, so the user can decide the temperature and time to be processed next by microcontroller. The initial Autoclave has been equipped with buzzer used as an alarm when the tool is not closed well and when the tool has finished operating

Page 1 of 1 | Total Record : 10