cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
PIN Pengelolaan Instalasi Nuklir
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Majalah Ilmiah Pengelolaan Instalasi Nuklir "PIN" yang diterbitkan oleh Pusat Teknologi Bahan Bakar Nuklir (PTBN) - BATAN, menerima dan mempublikasikan naskah berupa hasil penelitian, kajian dan tinjauan ilmiah yang berhubungan dengan kegiatan pengelolaan instalasi nuklir
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 10, No 18 (2017): April 2017" : 6 Documents clear
PEMANTAUAN THERMOGRAPHY INFRAMERAH DALAM PEMELIHARAAN INSTALASI LISTRIK FASILITAS SARANA DUKUNG IEBE Ahmad Paid . .; Kusyanto . .; Eko Yuli Rustanto3 . .; Suhatno . .
PIN Pengelolaan Instalasi Nuklir Vol 10, No 18 (2017): April 2017
Publisher : PIN Pengelolaan Instalasi Nuklir

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (541.672 KB)

Abstract

ABSTRAKTelah dilakukan pemeliharaan instalasi listrik dengan menggunakan teknik thermography inframerah untuk mendukung kegiatan pemeliharaan dan perawatan fasilitas sarana dukung Instalasi Elemen Bakar Eksperimental (IEBE). Metode yang digunakan adalah dengan teknik thermography inframerah untuk scanning permukaan seluruh panel, selanjutnya menentukan titik panas (hot-spot) yang terindikasi terjadi kerusakan / over heat. Tujuan dari kegiatan ini untuk mengetahui kondisi instalasi listrik akibat penuaan yang dapat mengakibatkan kerusakan atau over heat dan melakukan tidakan perbaikan. Hasil pemeriksaan instalasi listrik fasilitas sarana dukung IEBE telah ditemukan kerusakan pada kabel power MCCB pompa skunder 8 dan kontaktor CDT.5, setelah dilakukan perbaikan pada MCCB pompa skunder 8 kabel fasa T yang semula fasa T= 55,1 - 103 oC, menjadi 41,7 - 45,7 oC,  sedangkan untuk kontaktor CDT.5 yang sebelum perbaikan dengan temperatur  27,4 – 88,1 oC setelah dilakukan perbaikan didapatkan temperatur  pada kontaktor = 23,6 - 40,5 oC. Dengan demikian setelah dilakukan perbaikan sistem yang mengalami kerusakan dapat bekerja kembali pada temperatur normal. Kata kunci: instalasi listrik, teknik thermography inframerah, over heat ABSTRACTMaintenance of Electrical installation has been done by using infrared thermography technique,  to support maintenance activities of facilities Experimental Fuel Element Installation (IEBE). The method is used by infrared thermography technique to scanning the entire panel surface, then determine hot spot   which indicated there is damage or over heat.  this activity is to know the condition of the electrical installation due to aging that can cause damage or over heat and make corrective action. electrical installation IEBE facility has found damage at MCCB power cable of secondary pump 8 and CDT.5 contactor, after repairing at MCCB of secondary pump 8 phase T cable from T = 55,1 - 103 oC to 41, 7 - 45.7 oC, while for CDT.5 contactors prior to repair with a temperature of 27.4 - 88.1 oC after the repair obtained temperature on contactor = 23.6 - 40.5 oC. Thus, after repairing the damaged system can work again at normal temperature. Keywords: electrical installation, infrared thermography technique, over heat
PENENTUAN LAJU KOROSI PADA AlMg2 SEBAGAI KELONGSONG BAHAN BAKAR NUKLIR MENGGUNAKAN AUTOCLAVE Yanlinastuti . .; Andi Haidir . .; Setia Permana . .
PIN Pengelolaan Instalasi Nuklir Vol 10, No 18 (2017): April 2017
Publisher : PIN Pengelolaan Instalasi Nuklir

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (428.121 KB)

Abstract

ABSTRAKPaduan AlMg2 sebagai bahan struktur cladding berfungsi untuk pengungkung bahan bakar nuklir. Telah dilakukan penentuan laju korosi paduan AlMg2 dalam medium air demineralisasi pendingin primer Reaktor Serba Guna GA Siwabessy (RSG-GAS) dengan parameter uji variasi suhu dan waktu pemanasan dalam  air demineralisasi berasal dari reaktor Serba guna BATAN Serpong Tangerang Selatan menggunakan Autoclave. Percobaan ini dilakukan pada suhu 100 dan 150oC yang dipanaskan secara terus menerus masing-masing selama 10, 15, 20 dan 30 hari. Tujuan percobaan ini untuk mengetahui laju korosi paduan AlMg2 dengan variasi suhu dan waktu pemanasan pada medium air demineralisasi pendingin primer Reaktor. Data hasil pengukuran dilakukan dengan cara penimbangan. Dari hasil penelitian menunjukkan bahwa paduan AlMg2 segar tanpa perlakuan rol (fresh) pada suhu pemanasan 100 oC selama 10, 15, 20 dan 30 hari dihasilkan laju korosi berturut-turut 0,9298; 1,2917; 1,7982; 2,7937 mpy dan pada suhu 150 oC dengan laju korosi adalah 0,9155; 1,3480; 1,7808; 2,7442 mpy sedangkan untuk  AlMg2  rol yang dipanaskan pada suhu 100 oC selama 10, 15, 20 dan 30 hari dengan laju korosi masing-masing 0,4054; 0,5052, 0,7049 dan 1,1498 mpy serta untuk AlMg2 rol pada suhu pemanasan 150 oC menghasilkan laju korosi berturut-turut yaitu 0,2966; 0,5126; 0,6857; 1,0966 mpy, dengan demikian bahwa paduan AlMg2 rol mempunyai laju korosi yang lebih kecil  dibandingkan dengan AlMg2 fresh pada pemanasan  100 maupun 150 oC. Laju korosi yang dihasilkan dari bahan AlMg2 dengan kategori ringan yaitu mempunyai laju korosi dibawah 20 mpy, sehingga paduan AlMg2 relatif lebih tahan sebagai kelongsong bahan bakar nuklir di lingkungan air reaktor.  Kata kunci : korosi, AlMg2, kelongsong bahan bakar nuklir, autoclave ABSTRACT AlMg2Alloy as a cladding material serves to contain nuclear fuel. Corrosion rate of AlMg2 alloy in medium water demineralization of primary coolant GA Siwabessy Multipurpose Reactor (RSG-GAS) with parameters of test variation of temperature and heating time in water demineralized came from reactor of Serba guna BATAN Serpong Tangerang Selatan using Autoclave. The experiments were carried out at 100 and 150 °C temperatures heated continuously for 10, 15, 20 and 30 days respectively. The purpose of this experiment was to find out AlMg2 alloy corrosion rate with variation of temperature and heating time on medium water demineralization of primary coolant  reactor. The measurement data is done by weighing. The results showed that fresh AlMg2alloys without fresh roll treatment at 100° C for 10, 15, 20 and 30 days were produced at 0.9298 corrosion rate; 1.2917; 1.7982; 2.7937 mpy and at a temperature of 150oC with a corrosion rate of 0.9155; 1.3480; 1.7808; 2.7442 mpy whereas for AlMg2 rolls heated at 100°C for 10, 15, 20 and 30 days with a corrosion rate of 0.4054 respectively; 0,5052, 0,7049 and 1,1498 mpy  and for AlMg2 roller  at heating temperature 150oC yields corrosion rate respectively that is 0,2966; 0.5126; 0.6857; 1.0966 mpy, So that the AlMg2  alloy roll has a smaller corrosion rate compared to fresh AlMg2 at 100 or 150oC heating. The corrosion rate generated from AlMg2 material with the light category has a corrosion rate below 20 mpy, so the AlMg2alloy is relatively more resistant as a nuclear fuel cladding in the environment of the water reactor. Keywords: corrosion, AlMg2, nuclear fuel cladding, autoclave
ANALISIS LAJU KOROSI PADUAN ALUMINIUM FERONIKEL PADA pH BASA DENGAN POTENSIOSTAT Andi Haidir . .; Yanlinastuti . .; Anditania Sari Dwi Putri Tania Dwi Putri; Ely Nurlaily Ely Nurlaily
PIN Pengelolaan Instalasi Nuklir Vol 10, No 18 (2017): April 2017
Publisher : PIN Pengelolaan Instalasi Nuklir

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (553.438 KB)

Abstract

ABSTRAKANALISIS LAJU KOROSI PADUAN ALUMINIUM FERONIKEL PADA pH BASA DENGAN POTENSIOSTAT. Aluminium Feronikel (AlFeNi) adalah salah satu kandidat  kelongsong alternatif masa depan karena  mempunyai keunggulan, diantaranya dalam suasana  netral dan normal, laju korosinya dapat diterima. Tujuan penelitian ini  adalah mengetahui  laju korosi  AlFeNi pada pH yang ekstrim sebagai langkah antisipatif untuk mencegah  terjadinya  kekritisan  reaktor. Metode yang digunakan  untuk karakterisasi  korosi adalah  metode  Tahanan Polarisasi  dan metode Tafel menggunakan potensiostat. Hasil penelitian menunjukkan  bahwa pada  pH 11,19 ; 12,41 ; 12,62;  12,76;  laju korosinya bertambah  seiring dengan  naiknya pH. Untuk metode polarisasi  resistensi diperoleh  nilai laju korosi untuk masing-masing pH tersebut adalah  47,05 mpy ; 437,467 mpy ;  778,1 mpy ; 993,367 mpy . Sedang  metode Tafel  laju korosi berturut-turut 47,003 mpy ; 334,533 mpy ; 632,633 mpy  897,7 mpy. Dengan demikian dapat disimpulkan bahwa dengan bertambahnya pH medium dalam sel uji korosi maka laju korosinya pun bertambah. Kata kunci : Laju korosi, potensiostat, polarisasi resistensi, Metode Tafel. ABSTRACTANALYSIS CORROSION RATE OF ALUMINIUM FERONICKEL IN BASE pH BY POTENSIOSTAT.  AlFeNi  is one alternative cladding for future because of its advantages.  In neutral and normal condition, corrosion rate of AlFeNi can be accepted. However  as may be necessary to determine the corrosion rate at pH extremes as anticipatory measures to prevent reactor criticality. The method is used to characterize corrosion such as polarization resistance method and Tafel method using potensiostat. From the results obtained indicate that the pH used the pH 11,19 ; 12,41 ; 12,62 and 12,71 corrosion rate increases. For the method of polarization resistance corrosion rate values obtained for each pH are : 47,05 mpy ; 437,467 mpy ; 778,100 mpy ; 933,367 mpy. Tafel method of corrosion rate were respectively : 47,003 mpy ; 334,533 mpy ; 632,633 mpy ; 897,7 mpy. It can be concluded that with increasing pH of the medium in the corrosion test cell corrosion rate  is greatly increased. Keywords : AlFeNi, corrosion rate, potensiostat, polarization resistence, Tafel Metode.
UPGRADE SISTEM DETEKTOR PCD KE SDD PADA ALAT XRF QUANT’X IRM Helmi Fauzi R Helmi R.; Agus Jamaludin Agus Jamaludin
PIN Pengelolaan Instalasi Nuklir Vol 10, No 18 (2017): April 2017
Publisher : PIN Pengelolaan Instalasi Nuklir

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (467.912 KB)

Abstract

 ABSTRAKKemajuan teknologi pendeteksi hasil sinar  X - Ray fluoresence semakin berkembang, adanya teknologi elektronik semikonduktor membuat sistem pendeteksian semakin ramping dan simpel. Penggantian bagian detektor alat XRF Arl – quant’X bertujuan untuk memperbaiki sekaligus meningkatkan kemampuan alat tersebut di instalasi radiometalurgi- PTBBN. Peningkatan performa X –ray fluorescence dengan meng – upgrade dari PCD (Peltier Cooled Detector) ke SDD (Silicon Drift Detector) berhasil dibuktikan dengan data kalibrasi gain DAC yang sesuai pengaturan (setting), Uji kestabilan operasi di perulangan 50 kali proses yang memenuhi kategori stabil  (On Spec), nilai resolusi terbaik yang ditunjukkan oleh nilai Full Width at Half Maximum (FWHM) sebesar 158 KeV, dan hasil pengujian kualitatif dengan ketepatan identifikasi spektrum di setiap unsurnya (Zr, Sn, Cr & Ni) serta hasil pengujian kuantitatif komposisi unsur standard zirconium (Zr = 98 %, Sn = 1,4 % , Cr = 0,1% , Ni = 0,05 %) telah sesuai dengan sertifikat CRM JAEA yang menjadi acuannya. Kata Kunci : Upgrade, X-ray Fluoresence, PCD detector, SDD detector  ABSTRACTThe progress of x-ray detection technology with fluorescence is growing up, the presence  of semiconductor electronic technology makes detection system more slim and simple. The replacement of XRF Arl-quant'X detector section aimed at fixing and improving the equipment at the radiometallurgi installation – PTBBN. Improved performance of X -ray fluorescence by upgrading from PCD (Peltier Cooled Detector) to SDD (Silicon Drift Detector) has been proven with calibration data of adjustable DAC gain setting, he stability test operation in 50 repetitions of the process that meets the stable category (On Spec), the best resolution value shown by the value of Full Width at Half Maximum (FWHM) of 158 KeV, and the results of qualitative testing with the accuracy of spectrum identification in each element (Zr, Sn, Cr & Ni) and the result of quantitative testing of standard zirconium element composition (Zr = 98%, Sn = 1,4%, Cr = 0,1%, Ni = 0,05%) are in accordance with JAEA CRM certificate which become its reference . Keywords  : Upgrade,  X-ray Fluoresence,  PCD detector,  SDD detector.
ANALISIS UNJUK KERJA ALAT HELIUM LEAK DETECTOR Pranjono . .; Ngatijo . .; Torowati . .; Nur Tri Harjanto . .
PIN Pengelolaan Instalasi Nuklir Vol 10, No 18 (2017): April 2017
Publisher : PIN Pengelolaan Instalasi Nuklir

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (435.854 KB)

Abstract

ABSTRAKTelah dilakukan analisis uji unjuk kerja alat Helium Leak Detector berdasarkan hasil analisis pengujian Standar Leak Tes TL8.  Pelaksanaan dilakukan dengan mengumpulkan data hasil uji pengujian dengan standar laju uji kebocoran 2,80 x 10-8 mbar l/s. Pengujian dilakukan dengan 7 kali pengulangan.  Dari hasil tersebut diperoleh rata-rata perhitungan sebesar 2,76 x 10-8 mbar l/s dengan standar deviasi sebesar 9,00 x 10-11 mbar l/s. Rata rata hasil pengujian masih dalam keberterimaan standar kebocoran antara 2,38 x 10-8 mbar l/s sampai batas atas 3,22 x 10-8 mbar l/s..  Presisi hasil pengujian  memenuhi kriteria acceptance limit yaitu data berada pada rentang rata-rata ± 1 σ  atau berada diantara 2,75 x 10-8 mbar l/s dan 2,77 x 10-8 mbar l/s.  Kata kunci : Helium Leak Detector, Calibrator Leak TL8, Presisi, Akurasi. ABSTRACAn analysis of performance of leakage detector machine had been done based on Leak detector TL8 standard. The analysis is conducted using accumulated data from leakage detector using leakage rate of 2.80 x 10-8 mbar l/s. The detector is replicated seven times, which resulted an average of 2.76 x 10-8 and deviation standard of 9,00 x 10-11 mbar l/s. The result average is within acceptable standard of leakage, ranging from 2.38 x 10-8 mbar l/s to 3.22 x 10-8 mbar l/s. The precision of leakage detector result fulfilled criteria of acceptance limit, which stated the data should be in the range of average ± 1 σ, or between 2,75 x 10-8 mbar l/s and 2,77 x 10-8 mbar l/s. Key words : Helium Leak Detector, Calibrator Leak TL8, Precission, Accuracy
PENGATURAN TEKANAN GLOVE BOX - 101 SEBAGAI PERSYARATAN CRUSHING AND SIEVING PADA PROSES KONVERSI YELOW CAKE MENJADI SERBUK UO2 Triarjo . .; Sugeng Rianto Sugeng Rianto; Edy Muljono . .
PIN Pengelolaan Instalasi Nuklir Vol 10, No 18 (2017): April 2017
Publisher : PIN Pengelolaan Instalasi Nuklir

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (370.367 KB)

Abstract

ABSTRAKPilot Convertion Plant (PCP) adalah instalasi pilot pembuatan serbuk UO2. Yellow cake yang berasal dari uranium alam diolah menjadi serbuk UO2 melalui beberapa proses. Proses seksi 100 adalah proses untuk melakukan penimbangan, pengangkutan, Crusshing(pelumatan), dan sieving(pengayakan) yellow cake. Proses crusshing dan sieving yellow cake dilakukan didalam glove Box GB.101. Diperlukan pengaturan tekanan pada glove Box sebagai persyaratan proses crusshing dan sieving untuk menjamin keselamatan operator terhadap bahaya kontaminasi. Metode pengaturan tekanan dilakukan dengan cara mengatur posisi open/close pada katub depresurised, memutar bagian pengatur (just) pada pressure switch dan mengatur katub over/low tekanan pada glove box secara bergantian untuk mendapatkan tekanan hisapan udara didalam glove box sesuai Batasan kondisi operasi (BKO) yang dipersyaratkan pada sistem glove box yaitu tekanan -5 mmH2O  sampai dengan -15 mmH2O. Dari hasil pengaturan tekanan yang dilakukan, sistem pengaturan tekanan pada glove Box GB.101 dapat berfungsi dengan baik dan dapat dilakukan proses crusshing dan sieving sesuai dengan batasan keselamatan yang dipersyaratkan.                                                                                             Kata kunci - pengaturan, crusshing, sieving, pressure switch. ABSTRACTThe  Pilot Convertion Plant (PCP) is a pilot installation for production of UO2 powders. Yellow cake derived from natural uranium is processed into UO2 powder through several processes. The section 100 process for weighing, hauling, crushing, and sieving yellow cake. The process of crushing and sieving yellow cake is done inside in GB.101 glove Box. Pressure setting on Glove Box is required as crushing and sieving process requirements to ensure operator safety against contamination hazard. The method of pressure setting is performed by adjusting the open/close position of the depresurised valve, rotating the adjusting on the pressure switch and adjusting the over/low pressure valve on the glove box alternately to obtain the air suction pressure within the glove box as per the Operating conditions constraint required on the glove box pressure system at -5 mmH2O to -15 mmH2O. From the result of the pressure setting, the pressure setting system on glove Box GB.101 can work well and can be done crushing and sieving process in accordance with the required safety limitation. Keywords – setting, crusshing, sieving, pressure switch.

Page 1 of 1 | Total Record : 6