cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Jurnal Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir, Jurnal ilmiah diterbitkan oleh Pusat Rekayasa Perangkat Nuklir - BATAN Alamat Rekaksi: Pusat Rekayasa Perangkat Nuklir (PRPN) - BATAN
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 12, No 1 (2015): Juni 2015" : 6 Documents clear
PENENTUAN UKURAN CONTROL VALVE PADA UNIT PENGOLAHAN AIR BEBAS MINERAL IRADIATOR GAMMA PRFN Rissa Damayanti; Puji Santoso; Budi Santoso
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 1 (2015): Juni 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1424.218 KB)

Abstract

ABSTRAKPENENTUAN UKURAN CONTROL VALVE PADA UNIT PENGOLAHAN AIR BEBAS MINERAL IRADIATOR GAMMA PRFN. Instalasi air bebas mineral (demineralized water) berfungsi untuk mengolah air baku menjadi air bebas mineral menggunakan resin ion exchange, yang digunakan untuk keperluan pendingin dan perisai radiasi gamma. Air tersebut akan dialirkan pada kolam Iradiator melalui beberapa peralatan yang salah satunya adalah control valve yang berfungsi sebagai final control element. Air dalam kolam iradiator harus tetap terjaga levelnya, dimana low levelnya tidak boleh lebih rendah dari 30 cm. Untuk menentukan control valve yang sesuai dengan proses tersebut maka dilakukan penentuan ukuran (sizing) terlebih dahulu yaitu mengetahui nilai Cv (Coefisient valve) pada Control Valve. Untuk melakukan perhitungan/sizing pada control valve harus mengacu pada standart ISA: S75.01-1985 “Flow Equations for Sizing Control Valves”. Dari hasil perhitungan secara analitis berdasarkan persamaan pada standart ISA tersebut, dan dari perhitungan secara numerik menggunakan software first vue (fsm) diperoleh nilai Cv sebesar 6.31 pada kondisi normal operasi dengan ukuran valve 1 inci. Nilai Cv tersebut menunjukan pada kondisi normal, control valve bekerja pada bukaan katup sebesar 63%. Tipe control valve yang digunakan adalah globe valve, karakteristik alirannya equal percentage, prinsip kerjanya air to open. Dari hasil tersebut penggunaan control valve ukuran 1 inch telah sesuai karena tidak menimbulkan efek kavitasi ataupun flashing pada control valve yang dapat menimbulkan pemilihan material khusus dan berefek pada nilai ekonomis.Kata kunci: iradiator gamma, kolam iradiator, tangki penampungan, pengolahan air bebas mineral, control valve. ABSTRACTSIZING CONTROL VALVE ON DEMINERALISED WATER PROCESS FOR GAMMA IRRADIATOR PLANT OF PRFN. Installation of demineralized water is used to process the raw water into demineralized water using ion exchange resins which is used as coolant and gamma radiation shielding. The water will flow into the irradiator’s pool through several equipment in which one of them is a control valve which serves as the final control element. Water level of irradiator’s pool should be maintained, where the low level of water irradiator pool should not be lower than 30 cm. To select the control valve in accordance with the system, the first step is the determination of the size (sizing) which is to determine the value of Cv (Coefisient valve) on the Control Valve. For sizing the calculation of the control valve, it should refer to the standard ISA: S75.01-1985 "Flow Equations for Sizing Control Valves". From the result of analytical calculations according to the equation in standard ISA and the numerical calculation using the software first vue (FSM) is obtained Cv value of 6.31 on condition normal operation with a valve size is 1 inch. The Cv value indicates at normal condition in which the Control Valve working is at valve opening 63%. The type of control valve used is a Globe valve, flow characteristic is equal percentage, and working principle is air to open. From the calculation of Cv Control Valve for this application using Control Valve with size 1 inch is already suitable because it does not have the appropriate effect cavitation or flashing on Control Valve which can lead to the selection of specific materials and affect on its economic value.Keywords: gamma irradiator, irradiator’s pool, reservoir tank, demineralized water process, control valve
KALIBRASI AKUISISI CITRA PESAWAT SINAR-X PORTABLE DIG 1100 Fitri Suryaningsih; Andeka Tris Susanto
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 1 (2015): Juni 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (903.164 KB)

Abstract

ABSTRAKKALIBRASI AKUISISI CITRA PESAWAT SINAR-X PORTABLE DIG 1100. Radiografi digital adalah sebuah bentuk pencitraan sinar-X, dimana sensor-sensor sinar-X digital digunakan menggantikan film radiografi konvensional. Pengolahan citra secara kimiawi digantikan dengan sistem komputer yang terhubung dengan monitor atau laser printer sehingga hasil citra radiografi dapat langsung diamati serta mudah disimpan dan digunakan. Pesawat sinar X perlu dikalibrasi karena penggunaan pesawat sinar-X digital yang belum dikalibrasi menghasilkan citra yang kurang memuaskan. Karena ketika sinar-X tiba pada spesimen standar yang rata, bagian tengah akan menerima paparan yang lebih besar, sehingga pada citra yang dihasilkan, bagian tengah akan lebih terang dibanding bagian samping atau luar. Kalibrasi dilakukan untuk mengkompensasi efek ini. Dalam kegiatan kerekayasaan ini, kalibrasi dilakukan dengan akusisi dark frame tanpa menggunakan sinar-X dan akusisi bright frame dengan menggunakan pesawat sinar-X Kata kunci: kalibrasi, akuisisi, radiografi digital, sinar-X  ABSTRACTAN ACQUISITION IMAGE CALIBRATION OF THE DIG 1100 PORTABLE X-RAY EQUIPMENT. A digital radiography is a form of X-ray imaging where the digital X-ray sensors are used to replace conventional radiographic film. Chemical image processing is replaced with a computer-based image processing system which is connected to a monitor or a laser printer. The system allows the resulting radiographic image to be directly observed, and makes the image easy to store and use. The X-ray equipment used need to be calibrated prior to use since the use of uncalibrated digital X-ray equipment produces unsatisfactory images. The poor quality image is produced since when the X-ray arrives on a flat standard specimen, the central part receives a greater exposure, resulting in an image which is brighter in the center than in its edges or outer parts. The calibration is intended to compensate the effects of this variation in exposure. In this work, the calibration was performed through the acquisition of the dark frame without using x-rays and the acquisition of bright frame using the X-ray camera.Key words: calibration, acquisition, digital radiograhy, X-ray
ANALISIS DIMENSI LENGAN PADA MODEL RANCANGAN RENOGRAF THYROID UPTAKE TERPADU Sanda Sanda
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 1 (2015): Juni 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (301.689 KB)

Abstract

AbstrakANALISIS DIMENSI LENGAN PADA MODEL RANCANGAN RENOGRAF THYROID UPTAKE TERPADU. Model rancangan lengan renograf thyroid uptake terpadu sudah dibuat. Lengan merupakan salah satu komponen utama renograf thyroid uptake yang fungsinya untuk membawa kolimator ke posisi penyakit berada. Satu perangkat renograf thyroid uptake terpadu dalam rancangan ini mampu mendiagnosis dua fungsi organ, yaitu ginjal dan kelenjar gondok. Pada analisis ini yang menjadi masalah adalah menentukan diameter lengan dan jangkauannya yang optimal agar dihasilkan konstruksi mekanik yang mudah dioperasikan oleh operator. Untuk mengevaluasi kekuatan lengan akibat beban kolimator dan detektor, perlu dilakukan analisis model rancangan lengan renograf thyroid uptake terpadu. Hasil perhitungan secara analitik, pada geometrik diameter luar tangkai lengan yang diperoleh sebesar Ø60 mm, Ø48 mm, Ø42 mm dan Ø33 mm dengan displacement total pada tangkai sebesar 0,13 mm. Hasil yang diharapkan adalah lengan renograf thyroid uptake yang terkena beban sebesar 100 kg, pada panjang 600 mm, material mekaniknya dapat terjamin kekuatannya. Teknik yang digunakan, yaitu dengan cara membandingkan tegangan bengkok dan tegangan puntir yang terjadi terhadap tegangan tarik ijin bahan, sehingga konstruksi lengan renograf thyroid uptake terpadu bisa dijamin keamanannya.Kata kunci : analisis, rancangan, lengan, renograf, thyroid uptake. AbstractDIMENSIONAL ANALYSIS OF ARMS ON THE INTEGRATED RENOGRAF thyroid uptake MODEL DESIGN. An arm design on the integrated renograf thyroid uptake  has been made. The arm is one of the main components renograf thyroid uptake that function is to bring the collimator to position where the disease is located. The integrated renograf thyroid uptake is one equipment which is designed to be able to diagnose two organ functions, kidney and thyroid functions. The problem for the arm is that to have the optimal dimensions in order to produce the mechanical construction which is easily operated by the operator. To evaluate the arm strength due to colimator and detector loads, it is necessary to determine the arm dimensions in an analytic way. The analytic calculation results show that the geometric outer diameter shaft sleeve obtained by Ø60 mm, Ø48 mm, Ø42 mm and Ø33 mm with a total displacement on the stem of 0.13 mm. The expected result is that the arm of thyroid uptake having the load of 100 kg, the length 600 mm, it strength of material mechanically can be guaranteed. The technique to be used is by comparing the bending stress and torsional stress to the material tensile stress permits, so that the arm construction of the renograf thyroid uptake can be assurelly secure.Key words : analysis, design, arm, renograf, thyroid uptake.
PERANCANGAN SISTEM PENERANGAN BANGUNAN IRADIATOR GAMMA KAPASITAS 200 kCi Tukiman Tukiman; Edy Karyanta; Budi Santoso
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 1 (2015): Juni 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (750.198 KB)

Abstract

ABSTRAK           PERANCANGAN SISTEM  PENERANGAN BANGUNAN IRADIATOR GAMMA KAPASITAS 200 kCi. Telah dilakukan perancangan sistem penerangan dan perhitungan lampu untuk penerangan bangunan iradiator gamma kapasitas 200 kCi. Rancangan sistem penerangan yang baik, bertujuan agar dapat  meningkatkan produktivitas kerja, peningkatan kesehatan, kecermatan penglihatan dan suasana kerja yang lebih nyaman sesuai dengan standar yang berlaku. Kualitas pencahayaan dipengaruhi oleh warna dinding dan langit-langit. Jumlah titik lampu yang direncanakan dalam bangunan iradiator ini adalah 124 titik. Ukuran ruangan lantai 1 panjang: 30,7 m, lebar: 15,95 m dan tinggi: 5 m, serta ukuran ruangan lantai 2 adalah: panjang: 14,2 m, lebar: 13,1 m, tinggi: 4 m, dengan satu titik armature terdiri 2 (dua) buah lampu. Dalam rancangan ini digunakan sistem penerangan langsung. Jenis lampu yang digunakan adalah TL day light 36 watt, dengan konsumsi jumlah daya listrik sebesar 4365 watt.   Kata kunci :  Lampu, rancangan, perhitungan sistem penerangan. ABSTRACTLIGHTING SYSTEM DESIGN OF 200 kCi GAMMA IRRADIATION FACILITY. A lighting system design and lamp computation of 200 kCi gamma irradiation facility has been carried out. A good lighting system design is intended to increase work productivity, health improvement, precision vision and a more comfortable working environment in accordance with the applicable standards. Lighting quality is influenced by the color of the walls and ceilings. The number of lamp in this irradiators building is design 124 points. The size of the room at the first floor is 30.7 m length, 15.95 m width, and 5 m height, while at the 2nd floor is 14.2 m length, 13.1 m width, 4 m height, with a single point of the armature comprises two (2) pieces of light. A direct lighting system is used in this design. The type of lamp used is TL day light 36 watt, with the total electric power consumption of 4365 watts..Keywords : Lighting, design, lighting calculation system.
PEREKAYASAAN PERANGKAT PEMANTAU RADIASI LINGKUNGAN INSTALASI NUKLIR Istofa Istofa; Leli Yuniarsari; I Putu Susila
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 1 (2015): Juni 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (426.831 KB)

Abstract

ABSTRAK     PEREKAYASAAN PERANGKAT PEMANTAU RADIASI LINGKUNGAN INSTALASI NUKLIR. Dalam suatu kawasan instalasi nuklir, bahan radioaktif seperti sejumlah kecil limbah gas dan partikulat yang mengandung radioaktif dapat terlepas dari setiap fasilitas melalui cerobong ke udara. Pelepasan bahan radioaktif akan meningkatkan risiko paparan radiasi di lingkungan. Untuk memantau paparan radiasi lingkungan dan untuk membangun sistem peringatan dini, sistem pemantauan   radiasi  dan cuaca yang berkelanjutan sangat diperlukan.  Pada kegiatan ini telah dilakukan Perekayasaan Perangkat Pemantau  Radiasi  Lingkungan  Instalasi  Nuklir.  Sistem  utama  terdiri  dari  Sistem  Monitor Radiasi  Gamma  dan  Sistem  Pemantau  Cuaca. Radiasi gross gamma diukur menggunakan detektor GM dan NaI(Tl), sedangkan untuk cuaca  yang  dipantau berupa arah dan kecepatan angin, temperatur udara, kelembaban relatif dan curah hujan. Prototip perangkat sudah dibuat dan dilakukan uji fungsi. Hasil pengujian pembangkit tegangan tinggi, pengolah sinyal radiasi, timer dan counter, ADC, serta modul komunikasi menunjukkan bahwa perangkat dapat berfungsi sesuai persyaratan. Berdasarkan hasil uji perbandingan dengan perangkat monitoring radiasi komersial, diperoleh hasil bahwa prototip yang dibuat mempunyai kinerja yang sebanding. Pengujian sensor cuaca juga menghasilkan unjuk kerja yang sesuai. Untuk selanjutnya, terhadap perangkat yang dikembangkan perlu dilakukan kalibrasi di laboratorium yang terakreditasi dan untuk selanjutnya data akan dikembangkan untuk dapat ditampilkan secara online di web.Kata Kunci : Perekayasaan, Pemantauan Radiasi, Lingkungan, Instalasi Nuklir           ABSTRACTAN ENGINEERING DEVELOPMENT OF ENVIRONMENTAL RADIATION MONITORING EQUIPMENT FOR NUCLEAR INSTALLATION. In a nuclear installation area, such small amount of radioactive material and waste gases containing radioactive particulates could be released from each facility through the chimney into the air. The radioactive release will increase the risk of radiation exposure in the environment. To monitor environmental radiation exposure and to establish early warning systems, weather and continuous radiation monitoring systems are needed. Engineering development of Environmental Radiation Monitoring Equipment for Nuclear Installations has been constructed in this activity. The main system consists of Gamma Radiation Monitor System and Weather Monitoring System. Gross gamma radiation is measured using a GM detector and NaI (Tl), while the weather such as wind speed, direction, air temperature, relative humidity and rainfall are also monitored. A prototype of device  has been created and the functions have also been tested. The results of high voltage generator testing showed that the radiation signal processing, timers and counters, ADC, and the communication module indicate that these devices are working properly. The constructed prototype obtained a good performance comparing to the commercial one. The testing on weather sensors devices also shows a good performance. Henceforth, these devices need to be calibrated using an accredited laboratory calibrator and furthermore the data will be developed to be displayed and accessed online on the web.Keywords : Engineering, Radiation Monitoring, Environmental , Nuclear Installation
DESAIN PERANGKAT KAIT OVERHEAD TRAVELLING CRANE DENGAN KAPASITAS ANGKAT 25 TON PADA PABRIK ELEMEN BAKAR NUKLIR Syamsurijal Ramdja; Petrus Zacharias
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 1 (2015): Juni 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1117.137 KB)

Abstract

ABSTRAKDESAIN PERANGAKT KAITOVERHEAD TRAVELLING CRANE DENGAN KAPASITAS ANGKAT 25 TON PADA PABRIK ELEMEN BAKAR NUKLIR. Telah dilakukan desain perangkat Kait Overhead Traveling Crane dengan kapasitas angkat 25 ton yang digunakan  pada pabrik elemen bakar nuklir. Kait  digunakan untuk memegang  bahan/material yang akan diangkat atau dipindahkan. Perancangan perangkat kait dilakukan dengan memperhatikan keamanan suatu data ukuran dan dimensi yang dipakai serta beban operasi apakah masih aman digunakan dalam kegiatan pengoperasian. Hal ini dilakukan untuk mengetahui apakah perangkat kait masih berada pada batas dimensi dan kekuatan bahan yang diizinkan. Desain ini berdasarkan pada standar ASME B30.2 yang berlaku dan dengan  faktor keamanan yang konservatif, terhadap : kait, bantalan aksial, pemikul kait dan sackle. Setelah dilakukan desain dan perhitungan, didapatkan bahwa perangkat kait yang terdiri dari kait, bantalan aksial, pemikul kait dan shackle dalam keadaan aman.Kata kunci : kait, kekuatan bahan, crane, schakle, bantalan ABSTRACTDESIGN OF HOOKS OF THE OVERHEAD TRAVELLING CRANE 25 TONS CAPACITY USED IN NUCLEAR FUEL ELEMENTS PLANT.  It has been design a hook overhead traveling crane with a lift capacity of 25 tons which is used in nuclear fuel elements plant. The hooks are used to hold the material to be removed or relocated. The design of hooks is conducted by considering to the safety factor of data and size dimensions to be used as well as its operational load whether still safe in its operating activities. This is done to determine whether the device is still in the material strength limit allowed. The design is based on the standards applicable of ASME B30.2 and with a conservative safety factors towards : hooks, axial bearings, latches and schakle bearers . After the design and calculations have been conducted, it was found that the hook consisting of hooks, axial bearings, bearer hook and shackle are in a safe condition.Keywords : hook, strength of materials, kran, schakle, bearings

Page 1 of 1 | Total Record : 6