cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota palu,
Sulawesi tengah
INDONESIA
SMARTek
Published by Universitas Tadulako
ISSN : -     EISSN : -     DOI : -
Core Subject : Education,
Arjuna Subject : -
Articles 7 Documents
Search results for , issue "Vol 4, No 3 (2006)" : 7 Documents clear
Pengaruh Batu Pecah Terhadap Kuat Tekan Paving Block Mallisa, Harun
SMARTek Vol 4, No 3 (2006)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (252.63 KB)

Abstract

Paving block (SK-SNI  T-4-1990-F) dapat diklasifikasikan  sebagai  beton pracetak tanpa tulangan  yang merupakan salah satu bahan lapis perkerasan  jalan. Paving block terbuat dari campuran bahan semen, pasir, dan air yang di cetak menurut ukuran pola tertentu. Pada penelitian ini, digunakan proporsi yang telah biasa digunakan di lapangan sebagai pembanding utama yaitu dengan perbandingan  1 semen: 8 pasir. Variasi campuran dilakukan terhapap komposisi pasir dan batu pecah. Variasi campuran semen, pasir dan batu pecah tersebut yaitu kombinasi 1 semen :(4,6,8) pasir:(4,6,8) batu pecah. Benda uji yang dibuat hanya dalam bentuk paving block ukuran standar 20x10x5 cm3.  Sedangkan cara pencetakan benda uji dilakukan secara manual seperti pada pembuatan di lapangan. Masing-masing benda uji dilakukan uji kuat tekan. Kedua jenis pengujian tersebut dilakukan dengan mesin manual dan digerakkan secara manual. Artikel ini menunjukkan pengaruh penambahan batu pecah pada kekuatan bahan paving block
Kaji Eksperimental Karakteristik Desain Dari Kompressor Stator Kaskade dengan British Profil 9C7/32, 5C50 Pada Stagger 30 Marsan, Kennedy
SMARTek Vol 4, No 3 (2006)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (513.032 KB)

Abstract

Karakteristik disain dari kompressor kaskade sangat di pengaruhi oleh 3 jenis fenomena stall, Blade stall, Corner Stall dan Wall Stall. Penelitian ini bertujuan untuk melihat pengaruh dari fenomena stall pada kompressor aksial yang mengggunakan British Profil 9C7/32,5 C50. Penelitian di simulasikan pada sebuah linear compressor cascade dengan variasi blade loading pada stagger 30.Hasil penelitian menunjukkan bahwa Seiring dengan peningkatan angle of attack (), harga air outlet angle (2) dan pressure loss cofficient akan cenderung konstan Kenaikan tekanan statis (Cp) sangat di pengaruhi oleh harga turning angle, dan pressure loss coefficient, hal ini menunjukkan meskipun telah terjadi corner stall pada hub, namun fenomena stall sangat di dominasi oleh fenomena blade stall, kondisi stall terjadi pada angle off attack= 18.5O
Prosedur Perancangan Sistem Pembangkit Listrik Tenaga Surya Untuk Perumahan (Solar Home System) Bachtiar, Muhammad
SMARTek Vol 4, No 3 (2006)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (284.171 KB)

Abstract

Energi listrik merupakan salah kebutuhan masyarakat modern yang sangat penting dan vital. Ketiadaan energi listrik akan sangat mengganggu keberlangsungan aktivitas manusia. Oleh karena itu kesinambungan dan ketersediaan energi listrik perlu dipertahankan. Bagi masyarakat yang tinggal di daerah perkotaan dan sekitarnya, energi listrik tidaklah menjadi masalah. Karena energi listrik yang disediakan oleh Perusahaan Listrik Negara (PLN) telah tersedia di kawasan tersebut. Namun bagi masyarakat yang tinggal di daerah-daerah pedalaman dan pulau-pulau terpencil, energi listrik merupakan suatu masalah besar. Karena jaringan listrik PLN belum menjangkau pada daerah tersebut. Solusi yang tepat untuk mengatasi ketiadaan energi listrik di daerah tersebut adalah mengubah  cahaya matahari yang melimpah menjadi energi listrik menggunakan teknologi photovoltaic. Sistem penyediaan listrik seperti ini disebut Pembangkit Listrik Tenaga Surya (PLTS). PLTS yang digunakan khusus untuk perumahan disebut Solar Home System (SHS). Pada makalah ini dibahas metoda perancangan pembangkit listrik tenaga surya untuk perumahan. Hasil dari perancangan ini diharapkan menjadi acuan bagi calon pengguna maupun praktisi listrik agar diperoleh kesesuaian antara kebutuhan energi, harga, dan kualitas yang tepat.
Corrosion Rates Measurements By Linear Polarisation and AC Impedance Techniques Using Different Steel Bars and Acidic Solution Turu’allo, Gidion
SMARTek Vol 4, No 3 (2006)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (308.197 KB)

Abstract

The corrosion rate of steel bars in concrete was affected by concentration of acid or pH level of concrete environment which covered the steel bars. This research was conducted by using different acid and concentration with different diameter and kind of steel bars. The results obtained from the test using both the polarisation resistance (LPR) and the AC impedance techniques are similar. This is because the acidic environment supports the corrosion process. It is also found that the type and diameter of bars immersed in acid solution and the concentration of acid are the determining parameters of the corrosion rates of the bars. Even the length of test period also affects the corrosion rates as the polarisation resistance decreases by time.
Pengadaan Rusun Sewa Sebagai Alternatif Permukiman Pekerja Industri di Desa Warugunung Karang Pilang Surabaya Sofyan, M. Yonni
SMARTek Vol 4, No 3 (2006)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (782.445 KB)

Abstract

Kawasan industri di Kelurahan Warugunung Kecamatan Karang Pilang merupakan salah satu wilayah pengembangan kawasan industri di kota Surabaya yang sampai saat ini terus berkembang. Perkembangan ini akan menimbulkan berbagai masalah diantaranya masalah pemukiman yang semakin tergeser dengan timbulnya kawasan industri yang kurang dibarengi dengan perencanaan hunian yang disesuaikan dengan tingkat pendapatan pekerja. Penelitian ini membahas tentang pengadaan rumah susun sewa untuk industri dan hunian sewa di kampung di sekitar kawasan rumah susun. Teknik pengumpulan data dilakukan dengan purpose sampling dengan metode diskripsi kualitatif, dengan metode tersebut di harapkan mampu mengungkap dan menjadi solusi positif tentang pemukiman pekerja industri.
Karakteristik Gerusan Pilar Segi Empat Ujung Bulat pada Kondisi Terjadi Penurunan Dasar Sungai dengan Proteksi Tirai Yunar, Alifi
SMARTek Vol 4, No 3 (2006)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (395.367 KB)

Abstract

Penelitian ini lebih ditekankan  pada tirai dan pilar yang dapat mengurangi kedalaman gerusan lokal pada saat terjadi penurunan dasar. Debit yang digunakan adalah 4.5 lt/dt dengan kedalaman aliran dari permukaan dasar 6.5 cm. Material pasir yang digunakan mempunyai nilai d50 = 0.043 cm dengan kondisi aliran live bed scour. Model pilar yang  digunakan berbentuk pilar segi empat ujung bulat (PSUB) dengan lebar 4 cm , panjang 12 cm dan tinggi 45 cm. Tirai yang dipakai dalam penelitian ini berupa silinder dengan diameter 0.3 cm variasi jarak antar tirai 2.4´1.2 cm, 3.6´1.8 cm. Variasi jarak tirai dan pilar, 12 cm dan 16 cm, serta variasi tinggi tirai dari dasar permukaan rerata pasir 1.2 cm, 3.6 cm, 4.8 cm dan 7.0 cm atau di atas permukaan air. Untuk setiap kali running percobaan dilakukan selama 300 menit. Dari analisis data diketahui bahwa, kedalaman relatif gerusan lokal maksimum terendah dicapai Pilar Segi Empat Ujung Bulat, kedalaman relatif gerusan lokal maksimum terendah dicapai pasangan tirai-pilar T1R2A1 dengan nilai 0.27 (nilai reduksi 68.64 %) pada saat terjadi penurunan dasar relatif 0.01. Dari hasil penelitian juga di peroleh bahwa Pilar Segi Empat Ujung bulat mempunyai nilai kedalaman relatif gerusan lokal maksimum rata-rata 0.64.
Analisis Perubahan Penggunaan Lahan dan Evaluasi Kekritisan DAS Kawasan Das Blongkeng Jawa Tengah Tahun 1993 - 2000 Budianta, Aziz
SMARTek Vol 4, No 3 (2006)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (556.045 KB)

Abstract

DAS Blongkeng merupakan Sub DAS Progo, terletak di Kabupaten Magelang dan Boyolali Propinsi Jawa Tengah, dan merupakan daerah tangkapan hujan yang cukup potensial secara lokal dan regional. Berdasarkan PP 47/1997 tentang Rencana Tata Ruang Wilayah Nasional, lereng tengah-atas DAS diklasifikasikan sebagai kawasan konservasi tanah dan air. Peningkatan jumlah penduduk serta aktivitas pembangunan selama tahun 1993 – 2000 telah mendorong terjadinya konversi lahan menjadi lahan terbangun. Hal ini akan mengganggu fungsi kawasan sebagai kawasan lindung dan konservasi. Tujuan penelitian adalah mengetahui luasan konversi lahan yang sudah terjadi, serta evaluasi kekritisan DAS yang dilakukan dengan pendekatan Model Indeks Konservasi (IK). Metode analisis meliputi: pembobotan dan analisis peta dengan SIG. Penelitian menunjukkan terjadi konversi lahan sebesar 10,94%, terutama untuk permukiman, lahan kosong, dan kebun. Lahan yang mengalami penyusutan adalah sawah, hutan, dan tegalan/ladang. Meskipun hasil evaluasi kondisi DAS menunjukkan kondisi DAS masih normal, akan tetapi ditemukan lahan kritis sebesar 1,51% yang perlu segera diatasi dengan metode konservasi lahan yang sesuai dengan kondisi fisik dan sosial-budaya setempat

Page 1 of 1 | Total Record : 7