p-Index From 2019 - 2024
0.444
P-Index
This Author published in this journals
All Journal Kappa Journal
Artawan, I Nengah
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Pengaruh Variasi Suhu Sintering Terhadap Struktur Kristalin Hidroksiapatit Tulang Iga Sapi Murzid, Jihan Qothrunada; Suharta, Wayan Gede; Spardi, I Wayan; Suardana, Putu; Kasmawan, I Gde Antha; Artawan, I Nengah; Prajitno, Djoko Hadi
Kappa Journal Vol 7 No 2 (2023): Agustus
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v7i2.20840

Abstract

A study entitled " The Effect of Sintering Temperature Variations on the Crystalline Structure of Bovine Bone Hydroxyapatite" has been carried out. The aim of this research is to understand how the sintering temperature influences the hydroxyapatite lattice parameters and to understand how the sintering temperature influences the volume and density of hydroxyapatite. The synthesis process begins with a calcination at 300 °C for one hour, followed by a sintering process with varying temperatures, namely 600 °C, 700 °C and 800 °C for samples A, B and C, respectively. To determine the hydroxyapatite content in the samples, then characterization using XRD was carried out. XRD results analysis was carried out using match3 and Rietica software. Identification results using match3 software obtained the presence of hydroxyapatite compounds and impurity compounds in the form of (Calcium trimagnesium carbonate huntite, Fluorine, Magnesium Hydrogensulfate Hydrate, Sassolite, Zemannite). The volume fraction of hydroxyapatite obtained in this study ranged from 68.6 – 82.8%. The higher the sintering temperature, the greater the volume fraction of hydroxyapatite. The Refinement results show that the higher the sintering temperature, the smaller the value of the lattice parameters in the direction of the a and c axes. Variations in sintering temperature also affect the resulting unit cell volume and density. The higher the sintering temperature, the smaller the unit cell volume, conversely the greater the unit cell density value.
Analisis Laju Dosis Radiasi di Area Ruang CT_Scan di Instalasi Radiologi RSU Bali Mandara Prameswari, Else Putri Ayu; Sutapa, Gusti Ngurah; Ayu Ratnawati, I Gusti Agung; Ratini, Ni Nyoman; Artawan, I Nengah; Trisnawati, Ni Luh Putu
Kappa Journal Vol 8 No 2 (2024): Agustus
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v8i2.25211

Abstract

Research has been carried out on radiation dose rate analysis in the CT-SCAN area of the radiology room at RSU Mandara Bali. The data used in this research is quantitative data observed from the radiation rate from the CT-SCAN aircraft. This study aims to determine the radiation dose rate in the radiology area and its rationalization based on regulations regarding radiation NBD (dose limit values) that apply to occupational safety and health. The research data is the actual radiation dose rate determined from the dose rate and calibration factors. The results of data calculations show that the highest dose rates are respectively at T2, 30 cm, 50 cm and 100 cm (door) with values of 1.95, 0.94 and 0.05 μSv/year, while the lowest dose rates are respectively at T4, 30 cm, 50 cm and 100 cm (waiting room) with values of 0.08, 0.06 and 0.05 μSv/year. The research results show that the dose rate at each measurement point is still considered safe for radiation workers where the NBD received is still below 20 μSv/year, while the dose rate is classified as safe for the general public at measuring distances of 50 cm and 100 cm, where the NBD received is below 1 μSv/year assuming the community concerned acts as a patient or patient's family with an interest in the radiology room area.