Claim Missing Document
Check
Articles

Found 22 Documents
Search

Risk Assessment of Total Coliform in X WTP’s Water Production Using Failure Mode And Effect Analysis Method Amanda, Bella Apriliani; Moesriati, Atiek; Karnaningroem, Nieke
TEKNIK Vol 38, No 1 (2017): (Juli 2017)
Publisher : Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (394.2 KB) | DOI: 10.14710/teknik.v0i0.15406

Abstract

The greatest risk of drinking water supply is a failure to provide safe drinking water for communities. Based on IPA Kedunguling testing report on March 2016 noted that sample exceeding the quality standart of Peraturan Menteri Kesehatan RI No 492/2010 for the total coliform quality standart. The presence of total coliforms indicating water contamination by pathogen means the water is not safe to consume. The disinfection process has an importance rule in pathogen inactivation. Disinfectant performance is influenced by temperature, pH, turbidity, and the presence of organic materials. One way to control the quality of water produced by using a risk management approach Failure Modes and Effect Analysis (FMEA) methods. The potential risks should be measured to determine causes of the problems and find the appropriate risk reduction. The risk assessment is using Risk Priority Number (RPN) scale as a basis prioritization of remedial action on issues. Based on identification and risk analysis using FMEA known that the greatest risk of failure is the stipulation of chlorine dose and organic substances (category of high risk level); residual chlorine (category of moderate risk level); turbidity and pH (very low risk level category). Improvement proposal that can be done to reduce total coliforms presence in IPA Kedunguling is by increasing residual chlorine to 0.6 mg/l, set a daily chlorine level, controlling DBPs forming by lowering the concentration of organic precursor using granular activated carbon (GAC) or aeration, by lowering the dose of disinfectant, set aside DBPs after the compound is formed using granular activated carbon (GAC), turbidity and pH monitoring, and regularly washing the filters
Evaluation of Water Losses: Study Case in Intan Banjar Water Supply Company Setianingsih, Maria; Karnaningroem, Nieke
IPTEK Journal of Proceedings Series No 5 (2019): The 1st International Conference on Business and Management of Technology (IConBMT)
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1306.498 KB) | DOI: 10.12962/j23546026.y2019i5.6312

Abstract

Water losses from water distribution networks have become a crucial problem. The BNA (Basic Need Approach) zone has high water losses above the standard for maximum tolerance ministry of public work as 20%. The water losses during September - December 2018 has experienced a fluctuation. the highest losses occurred in October at 36.05%, but in November the level of water losses decreased to 34.17%. The water balance can be used to know to understand the quantity, source, and charge of water losses. The water balance calculation in this study uses the WB-Easy Calc program version 4.05. Based on the result, the percentage of water losses 34,81% with the composition of real losses as 30,61% and apparent losses of 4.21%. On the other hand, the financial impact by the water losses was deficit as Rp. 4.593.648.335. Furthermore, gets to the action for each one of the above main components of the water balance in order to reduce water losses.
Study of Remu River Water Quality Using Dynamic Program Thenu, Lebrina; Karnaningroem, Nieke
IPTEK The Journal for Technology and Science Vol 30, No 1 (2019)
Publisher : IPTEK, LPPM, Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (517.333 KB) | DOI: 10.12962/j20882033.v30i1.4998

Abstract

Remu River has been being a water resource for residents in Sorong City. Development in this city lead to water quality degradation of Remu River. Existing (2016) and prediction condition of Remu River in the next 2 years were defined by the behavior of BOD, COD, Fe, and DO that proceed using a dynamic program, STELLA 9.1.3. Study area involved 6 sampling points. Simulation results showed that BOD, COD, and Fe concentrations tend to increase in the next 2 years, even BOD and COD concentrations at several sampling points was higher than water quality standard, according to Government Regulation No. 82/2001. Meanwhile, DO concentration was below the limit in 4th to 6th sampling points. Pollution control strategy was conducted by setting up three scenarios: (1) procurement of Waste Water Treatment Plant (WWTP), (2) river sediment dredging, and (3) combination of both scenario. Combination of sediment dredging and procurement of WWTP scenario estimated to reduce BOD concentration to 89.82%, COD concentration to 87.02%, and increase DO concentration to 19.07%. So that, the 3rd scenario was determined as the best strategy to improve Remu River water quality, although Fe concentration cannot be controlled as it comes from nature.
Evaluasi dan Desain Ulang Unit Instalasi Pengolahan Air Limbah (IPAL) Industri Tekstil di Kota Surabaya Menggunakan Biofilter Tercelup Anaerobik-Aerobik Muzakky, Achmad; Karnaningroem, Nieke; Razif, Mohammad
IPTEK Journal of Proceedings Series No 5 (2017): Simposium I Jaringan Perguruan Tinggi untuk Pembangunan Infrastruktur Indonesia (2016)
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j23546026.y2017i5.3117

Abstract

Perkembangan dunia fashion saat ini membuat permintaan produk tekstil meningkat. Industri tekstil Z sebagai salah satu industri tekstil tua di Kota Surabaya berusaha untuk tetap bersaing dipangsa pasarnya dengan memproduksi berupa pakaian berwarna gelap. Peningkatan kegiatan produksi yang tidak diikuti dengan perubahan pada sistem pengolahan IPAL membuat perubahan pada karakteristik air limbah yang dikeluarkan oleh industri. Hal ini menyebabkan air yang dikeluarkan tidak memenuhi baku mutu. Sehingga diperlukan sebuah evaluasi dari setiap unit dan perencanaan ulang dari sistem IPAL. Perkembangan dunia fashion saat ini membuat permintaan produk tekstil meningkat. Industri tekstil Z sebagai salah satu industri tekstil tua di Kota Surabaya berusaha untuk tetap bersaing dipangsa pasarnya dengan memproduksi berupa pakaian berwarna gelap. Peningkatan kegiatan produksi yang tidak diikuti dengan perubahan pada sistem pengolahan IPAL membuat perubahan pada karakteristik air limbah yang dikeluarkan oleh industri. Hal ini menyebabkan air yang dikeluarkan tidak memenuhi baku mutu. Sehingga diperlukan sebuah evaluasi dari setiap unit dan perencanaan ulang dari sistem IPAL.Evaluasi dilakukan dengan mengukur dimensi dari masing-masing unit IPAL eksisting, menganalisa sampel air limbah, dan membandingkannya dengan kriteria desain dari masing-masing unit. Perencanaan ulang dilakukan pada unit yang tidak berfungsi dengan baik. Biofilter tercelup anaerobik-aerobik adalah salah satu teknologi yang dapat dijadikan sebagai alternatif karena memiliki banyak kelebihan dari aspek teknis dan finansial.Hasil evaluasi IPAL eksisting menunjukkan bahwa semua unit tidak memenuhi kriteria desain. Hal inilah yang menyebabkan air limbah yang dihasilkan tidak memenuhi baku mutu. Limbah yang dihasilkan IPAL eksisting adalah 52,05 mg/L TSS; 899,3 mg/L COD; 182,61 mg/L BOD; dan 31,85 PtCo warna. Rekomendasi berupa perencanaan ulang menggunakan biofilter tercelup anaerobik-aerobik menghasilkan limbah dengan kadar TSS, COD, BOD, dan warna secara berurutan adalah 15,93 mg/L; 29,05 mg/L; 2,99 mg/L; dan 2,63 PtCo dengan biaya investasi sebesar Rp 793.175.680.
Evaluation of PDAM Performance Using Dynamic Models Kristiawan, Helmi; Karnaningroem, Nieke; Kusuma, Maritha Nilam
Journal of Applied Sciences, Management and Engineering Technology Vol 1, No 1 (2020)
Publisher : Institut Teknologi Adhi Tama Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.jasmet.2020.v1i1.704

Abstract

the Regional Government is the fulfillment of basic needs of daily drinking water. However, the service by PDAM is still not optimal. It can be seen from the PDAM's performance that was “unhealthy from year to year according to BPPSPAM data. Some of the research methods used in analyzing PDAM performance are problem identification, identification of variables and conceptual models, dynamic model simulations, analysis and interpretation as well as drawing conclusions and suggestions. From the simulation result of dynamic models using Vensim PLE plus software, alternative scenarios were obtained, that will increase domestic water consumption and customer connections by 12.5% per year, increasing the repair and replacement of distribution piping systems and customer meters by 20% per year, and increasing rate to 15% per year.
Existing Evaluation and Efforts to Improve the Distribution Network of Banyuwangi District PDAM (Banyuwangi City Study Area) Setyawan, Danang Budi; Karnaningroem, Nieke
IPTEK Journal of Proceedings Series No 5 (2019): The 1st International Conference on Business and Management of Technology (IConBMT)
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j23546026.y2019i5.6283

Abstract

The drinking water sector is the aspect of development that has a pivotal function to support the welfare of society. This is due to health, lifestyle, residential environment conditions and comfort in daily life. The service of the piped water supply system (SPAM-JP) for the service of the capital city of Banyuwangi Regency covers 5 Subdistricts, with 44% clean water service coverage, installed production capacity of 405 liters/second and operating 330 liters/second, to service 34,319 Connection Units with customers domestic (Household) as many as 32,271 units and non-domestic as many as 2,046 units of connection. In addition, the level of continuity has not yet been achieved, this can be seen in some service areas during peak hours not flowing, besides the level of water loss is 25%. In anticipating all problems in the service, research is conducted by analyzing the technical aspects, financial aspects, and institutional aspects. In analyzing each aspect, it was used the appropriate method and updated data. The technical aspects was done by calculating water balance uses easy calk, network analysis using epanet 2.0 and determining improvement efforts. In the institutional aspects was done by the assessment of BPSPAM, while the financial aspects by analyzing the investment costs of network improvements required and alternative funding. The evaluation of existing conditions is that the production and distribution units are not optimal, in the water balance the water loss is 25%, from the HR assessment there is no activity to improve the existing HR and efforts to improve the distribution network include general improvements in the form of pipe replacement and DMA formation in all service areas and managements, namely by increasing HR and developing computer-based information systems
Studi Efisiensi Sistem Prasedimentasi dan Free Water Surface Wetland dalam Menurunkan Kadar Nitrat, Fosfat, Kekeruhan, Zat Organik dan Total Coli Raden Kokoh Haryo Putro; Atiek Moesriati; Nieke Karnaningroem
Jurnal Teknik ITS Vol 2, No 3 (2013)
Publisher : Direktorat Riset dan Pengabdian Masyarakat (DRPM), ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (220.622 KB) | DOI: 10.12962/j23373539.v2i3.5178

Abstract

Boezem Wonorejo saat ini telah dikembangkan menjadi tempat wisata yaitu Ekowisata Mangrove. Sampai saat ini pihak pengelola boezem masih kesulitan dalam penyediaan air bersihnya Sungai Jagir yang mengalir di sekitar wilayah Ekowisata tersebut merupakan sumber air permukaan yang berpotensi sebagai pemenuhan kebutuhan tersebut secara kuantitatif. Agar dapat terpenuhi secara kualitatif, maka Perlu dilakukan penelitian awal untuk mengetahui efisiensi penurunan kadar Nitrat, Fosfat, Zat Organik, Kekeruhan maupun Total Coli. Dalam penelitian ini akan digunakan rangkaian suatu sistem pengolahan Prasedimentasi dan Free Water Surface wetland skala laboratoium, Dengan variabel ukuran media pasir (16-32 mesh dan lolos 32 mesh) dan umur mangrove (3 bulan dan 6 bulan) yang akan di analisis di laboratorium Teknik Lingkungan ITS.  Dari hasil analisis didapat removal maksimum  untuk kekeruhan pada prasedimentasi 46,5%, sedangkan pada wetland yaitu pada media pasir mesh 16-32 dan mangrove 6 bulan yaitu 94,8%. Presentase maksimum removal nitrat pada prasedimentasi yaitu 17,8%, removal maksimum pada wetland dengan mangrove 6 bulan dan media pasir lolos 32 mesh yaitu 53,6%. Pada mangrove sendiri removal makismum terdapat pada umur 6 bulan dengan besar removal 36,5%. Removal maksimum fosfat terbesar pada prasedimentasi yaitu 64,3%, untuk Reaktor Wetland yaitu pada wetland dengan mangrove 6 bulan dan media pasir lolos mesh 32 sebesar 90,5%. Untuk . Mangrovenya sendiri mampu meremoval maksimum pada umur 6 bulan dengan besar 53,8%. Presentase removal maksimum zat organik pada prasedimentasi sebesar 35,7%, pada reaktor wetland sebesar 21,8% dengan ukuran media pasir mesh 16-32 dan umur mangrove 3 bulan.
Studi Efisiensi Sistem Prasedimentasi dan Subsurface Flow Wetland dalam Menurunkan Kadar Kekeruhan, Zat Organik, Nitrat, Fosfat, dan Total Coli Trio Agustika; Nieke Karnaningroem; Atiek Moesriati
Jurnal Teknik ITS Vol 2, No 3 (2013)
Publisher : Direktorat Riset dan Pengabdian Masyarakat (DRPM), ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (326.779 KB) | DOI: 10.12962/j23373539.v2i3.5180

Abstract

Terdapat beberapa kandungan dalam air seperti kekeruhan, zat organik, nitrat, fosfat, dan total coli. Kandungan-kandungan tersebut dijadikan parameter dalam menentukan kualitas air. Tujuan penelitian ini adalah mengkaji efektifitas penurunan kadar kekeruhan, nitrat, fosfat, zat organik, dan total coli pada Sungai Jagir di sekitar Taman Boezem Wonorejo. Penelitian ini dilakukan dengan menggunakan sistem Prasedimentasi dan Subsurface Flow Wetland dengan variasi umur tanaman mangrove dan ukuran media pada wetland. Umur mangrove yang digunakan adalah 3 bulan dan 6 bulan. Sedangkan ukuran media yang digunakan adalah 16-32 mesh dan 32-50 mesh. Penilitian ini dilaksanakan selama dua minggu. Dari hasil penelitian didapatkan penurunan paling optimum sebagai berikut, kekeruhan sebesar 99,6%, sebesar 46,07% pada zat organik, sebesar 69,8% pada Nitrat, sebesar 76,19% pada Fosfat, dan pada Total coli sebesar 99,2%. Penurunan kadar tersebut disebabkan adanya proses filtrasi yang terjadi pada media pasir, dan juga adanya proses penyerapan nutrien yang dilakukan oleh tanaman mangrove itu sendiri.
Analisis Daya Tampung Beban Pencemaran Kali PelayaranKabupaten Sidoarjo Dengan Metode Qual2kw Panthera Grandis Raga Irsanda; Nieke Karnaningroem; Didik Bambang
Jurnal Teknik ITS Vol 3, No 1 (2014)
Publisher : Direktorat Riset dan Pengabdian Masyarakat (DRPM), ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (439.917 KB) | DOI: 10.12962/j23373539.v3i1.5681

Abstract

Pencemaran Kali Pelayaran berasal dari limbah domestik, limbah industri dan persawahan di sekitar bantaran sungai. Penelitian ini adalah untuk mengaplikasikan dan mengevaluasi dengan metode Qual2kw dengan menggunakan 4 simulasi skenario kualitas air, serta menghitung daya tampung beban pencemaran Kali Pelayaran. Sedangkan parameter yang di uji meliputi DO, BOD, COD, TSS, Fosfat (PO4 3-), Nitrat (NO3) dan Amonium (NH4). Wilayah studi dimulai dari hulu hingga depan IPA Taman Tirta sepanjang 21 km.Berdasarkan perhitungan daya tampung beban pencemaran maka didapatkan daya tampung maksimumdan daya tampung minimumpada tiap segmen.Hasil dari aplikasi dan evaluasi dengan Qual2kw pada Kali Pelayaran dalam kondisi telah tercemar.
Pengolahan Air Limbah Domestik Menggunakan Proses Aerasi, Pengendapan, dan Filtrasi Media Zeolit-Arang Aktif Afiya Asadiya; Nieke Karnaningroem
Jurnal Teknik ITS Vol 7, No 1 (2018)
Publisher : Direktorat Riset dan Pengabdian Masyarakat (DRPM), ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (178.402 KB) | DOI: 10.12962/j23373539.v7i1.28923

Abstract

Produksi air limbah domestik khususnya greywater yang dihasilkan dari aktivitas manusia setiap harinya semakin meningkat sejalan dengan peningkatan jumlah penduduk. Adapun kualitas air limbah domestik masih jauh melebihi baku mutu yang telah ditetapkan pemerintah. Air limbah domestik atau rumah tangga yang tidak diolah secara benar dapat menyebabkan berbagai macam masalah bagi manusia dan lingkungan sekitarnya. Diperlukan pengolahan yang tepat untuk dapat mengolah air limbah domestik agar dapat memenuhi baku mutu air bersih, dan dapat digunakan sebagai sumber air bersih oleh masyarakat. Penelitian ini dilakukan untuk menentukan efektivitas pengolahan air limbah dengan menggunakan proses aerasi, sedimentasi dan filtrasi media zeolit-arang aktif menggunakan sistem kontinyu. Proses aerasi dilakukan dengan penambahan larutan EM4 sebagai pengolah zat organik yang ada pada air limbah, dan kemudian air limbah akan melewati bak pengendap untuk mengendapkan zat padat yang terkandung didalamnya. Selanjutnya, air limbah akan diolah menggunakan filter dengan media zeolit dan arang aktif. Setelah melewati serangkaian pengolahan dengan proses aerasi, sedimentasi, dan filtrasi menggunakan zeolit dan arang aktif, hasil penelitian menunjukkan terjadinya penurunan kandungan pencemar pada air limbah. Rata-rata penyisihan kandungan zat organik adalah ialah 93,14%, rata-rata penyisihan nilai N adalah 99,81%, rata-rata penyisihan nilai P adalah 99,67%, dan rata-rata penyisihan nilai TDS mencapai 84,76%, serta nilai penyisihan TSS ialah 99,97%.