Claim Missing Document
Check
Articles

Found 16 Documents
Search

ANALISIS PEMANTAUAN INFUS PERISTALTIK BERBASIS SENSOR TCRT 5000 Dabukke, Hotromasari; Rajagukguk, Desy Lustiyani Rajagukguk Lustiyani; Sijabat, Salomo; Adiansyah, Adiansyah
-
Publisher : RELE (Rekayasa Elektrikal dan Energi) : Jurnal Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30596/rele.v6i2.16530

Abstract

Abstrak— Penelitian ini bertujuan untuk menganalisis keakuratan TCRT5000 sebagai sensor berdasarkan pembacaan sistem pada pompa infus. Peralatan ini terdiri dari sensor TCRT5000, rangkaian komparator, rangkaian menstabil, motor stepper, driver motor L298N, dan mikrokontroler ATmega328. Sensor TCRT 5000 membaca tetesan cairan infus yang diberikan, kemudian diperkuat oleh rangkaian komparator dan menstabil, setelah itu pembacaan laju aliran dan volume sisa dihasilkan oleh mikrokontroler ATmega328. Selanjutnya data ini dikirim melalui nirkabel HC-11. Metode penelitian dilakukan dengan menghitung laju aliran menggunakan alat Infuse Device Analyzer dengan menunjukkan nilai error, dan nilai error dihitung pada sistem pada dosis 30 ml/jam dan nilai error terendah pada setting 100ml/jam. Hasil penelitian diperoleh data bahwa data laju alir IDA mempunyai kecepatan dengan sensor laju alir 80 ml/jam dengan rata-rata penurunan sebesar 14,20 dengan error sebesar 1,5% dengan laju error sebesar 0,2 tetes/menit dengan minimum kecepatan 0,42 tetes/menit dengan besarnya 0,16 tetes/menit. Untuk perancangan pompa infus menggunakan sensor TCRT 5000 dengan nilai error yang sangat kecil terdapat pada 100 ml/jam dengan rata-rata drop sebesar 16,22 dengan error sebesar 1,2% dengan error rate sebesar 0,3 tetes/menit dengan kecepatan minimal sebesar 0,41 tetes /menit dengan besarnya 0,15 tetes/menit. Berdasarkan hasil penelitian dapat diartikan bahwa nilai error tidak melebihi batas toleransi kalibrasi. Keakuratan data yang diperoleh lebih tinggi jika dibandingkan dengan menggunakan sensor fotodiode inframerah. Dari pengolahan data, laju aliran IDA mempunyai error sebesar 2,2%. nilai pada waktu alir 30 ml/jam, 1,15% pada waktu alir 60 ml/jam, dan 0,58% pada waktu alir 100 ml/jam sehingga alat ini dapat digunakan untuk meningkatkan keakuratan alat dan dapat menghindari kesalahan dalam pemberian infus pada pasien.
ANALISIS KECEPATAN PUTARAN HOTPLATE MAGNETIC STIRRER BERBASIS ARDUINO UNO Dabukke, Hotromasari; Primasyukra, Mhd. Aldi; Lasiyah, Nani; Gaol, Midun Andrike Lumban
JURNAL MUTIARA ELEKTROMEDIK Vol. 7 No. 1 (2023): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v7i1.4495

Abstract

The Arduino Uno Based Hotplate Magnetic Stirrer Rotational Speed ​​Design has been successfully carried out. The function is to stir and heat one solution with another solution which aims to make a homogeneous solution with the help of a Magnetic stir bar (Stir Bar). The purpose of this design is to know the design of the HotPlate Magnetic Stirrer with 400 Rpm Rotation Speed ​​Settings and to determine the accuracy of the Hotplate Magnetic Stirr rotation speed. The method used is the experimental method. The components in this design are Arduino uno and consist of DC Stepper motor components, motor drivers, 20x4 lcd. The working principle of the design of the hotplate magnetic stirrer based on Arduino Uno. The PLN AC 220V current enters the power supply which converts to a DC voltage of 12V 10A, then Arduino Uno receives a DC voltage of 12V to turn on circuits such as motor drivers that require 12V voltage directly from the power supply, 9V stepper motors, 5V buzzers. Furthermore, the stepper motor will run according to the command set on keyped. To compare the rotational speed settings, use the tachometer calibration tool. The test results show the Rotational Speed ​​of the Arduino Uno-Based Hotpate Magnetic Stirrer, the rpm rotation speed is in accordance with the settings and the results obtained are 10% tolerance. The results of measuring the voltage on the power supply.
PEMANTAUAN DAN KONTROL REAL TIME INKUBATOR NEONATAL Sijabat, Salomo; Rajagukguk, Desy Lustiyani; Dabukke, Hotromasari; Adiansyah
JURNAL MUTIARA ELEKTROMEDIK Vol. 7 No. 2 (2023): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v7i2.4944

Abstract

Telah dilakukan penelitian dengan membuat alat inkubator bayi yang dapat berfungsi secara otomatis pemantauan dan kontrol real-time inkubator neonatal. Kontrol suhu dan kelembaban sistem monitoring sangat dibutuhkan dalam sebuah inkubator karena saat ini masih banyak suhu pemantauan dilakukan secara manual. Demikian pemantauan dan pengendaliannya sistem suhu dan kelembaban inkubator telah dirancang yang dapat dipantau secara otomatis dari jarak yang cukup jauh berdasarkan Internet Of Things (IoT). Metode penelitian ini terdiri dari 2 bagian sistem yaitu perangkat utama dan perangkat pemantauan. Sensor yang digunakan adalah DHT11 untuk temperatur dan kelembaban, serta sensor DS18B20 untuk suhu ruangan. Pemantauan dapat dilakukan secara real-time dan pengontrolan manual dapat dilakukan dan ditampilkan pada LCD. Jika suhu dan kelembaban tidak cocok, pemanas atau kipas DC akan menyala. Penelitian ini adalah membuat alat inkubator yang dapat berfungsi secara otomatis pemantauan dan kontrol real-time inkubator neonatal. Hasil penelitian nilai kesalahan setiap kondisi suhu sedang diuji dapat diketahui dengan pasti besaran kesalahan (eror) yang terjadi pada setiap perlakuan hal ini akan memberikan gambaran tentang keakuratan alat yang digunakan dari data tersebut diperoleh nilai kesalahan rata-rata dari ke 13 kali percobaan adalah sebesar 0,09% demikian juga halnya perbandingan dengan pembanding termometer digital dan termometer air raksa. Jadi, tingkat akurasi peralatan sensor yang digunakan dengan pendeteksi suhu DS18B20 adalah mencapai 99,91% .
ANALISIS PEMELIHARAAN KOREKTIF PADA ALAT HFNC (High Flow Nasal Cannula) Mukhlis, Alfi; Dabukke, Hotromasari; Ulina, Sri; Sijabat, Salomo
JURNAL MUTIARA ELEKTROMEDIK Vol. 8 No. 1 (2024): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v8i1.5144

Abstract

Ventilator is a mechanical assistive device that functions to provide artificial respiration to patients by providing negative or positive air pressure to the lungs through the airways. who can maintain ventilation and administration of oxygen for long periods of time (Brunner and Suddarth, 2001). While the HFNC (High Flow Nasal Cannula) Ventilator is a Ventilator specifically used for the treatment of patients suffering from acute hypoxemia. It is necessary to carry out maintenance so that the tools with this type of research are of high quality The measurement result is the oxygen gas flow rate, according to the size of the flowrate selection, namely 30 lpm, 45 lpm and 60 lpm.
RANCANG BANGUN TIMER DAN WATER LEVEL SENSOR PADA ALAT NEBULIZER BERBASIS ARDUINO UNO Nasution, Muhammad Ananda Rifky; Dabukke, Hotromasari; Primasyukra, Mhd.Aldi
JURNAL MUTIARA ELEKTROMEDIK Vol. 7 No. 2 (2023): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v7i2.5303

Abstract

A nebulizer is a piece of equipment used to convert liquid medication into an aerosol that will be inhaled by the user according to a doctor's prescription. The design of a timer and water level sensor on an Arduino Uno-based nebulizer was carried out to make it easier for users to operate and add an automation system that is integrated with an Arduino Uno type microcontroller. This design has the same device concept as a nebulizer in general, but adds a timer system via an attached push button and relay. Apart from that, the addition of a water level sensor is used to detect the amount of fluid in the reservoir. This design uses an experimental concept with narrative qualitative research methods. Device design is divided into 2 types, namely hardware and software. Programming using Arduino IDE and circuit simulation using Proteus. The design was successfully made and testing was carried out on the timer and water level sensor. The nebulizer worked according to its function and the timer test error value was 0.018704323 with a comparison difference with the stopwatch of 0.5 seconds.  
ANALISA PEMELIHARAAN KOREKTIF PADA ALAT PATIENT MONITOR DI RUMAH SAKIT UNIVERSITAS SUMATERA UTARA Wahyudi, Dody; Dabukke, Hotromasari; Sijabat, Salomo
JURNAL MUTIARA ELEKTROMEDIK Vol. 8 No. 1 (2024): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v8i1.5305

Abstract

Patient monitor is a tool that functions to monitor the physiological condition of patients. Where the monitoring process is carried out in real-time. The purpose of this analysis is to find out how this corrective maintenance is carried out starting from the beginning to the end of the process. With this research, the author will get valid data about patient monitor tools, this research is also carried out in accordance with the rules of the law so that no violations will be created. The reason for using this patient monitor is so that things do not happen that can make the patient's condition worse and also medical technicians can find out the patient's condition in real time, in other words this patient monitor tool is made to assess the current condition of the patient and evaluate the influence of the patient's intervention. This monitoring tool can measure vital signs in patients, such as temperature, blood pressure, respiration, pulse rate which are displayed directly on the patient monitor screen itself in real time Corrective maintenance analysis on this patient monitor is equipped with a calibration tool that can help carry out this activity.
UPAYA PENCEGAHAN PENULARAN COVID-19 DENGAN SOSIALISASI PEMBUATAN HAND SANITIZER DI SMK NEGERI 5 MEDAN Sijabat, S; Adiansyah, Adiansyah; Dabukke, Hotromasari
Jurnal Abdimas Mutiara Vol. 1 No. 2 (2020): JURNAL ABDIMAS MUTIARA
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Semakin meningkatnya kasus covid-19 di Indonesia memiliki dampak kesehatan yang cukup besar bagi masyarakat. Pertumbuhan virus covid-19 menempel pada tangan setiap harinya melalui kontak fisik dengan lingkungan, dan diantaranya dapat menyebabkan/menimbulkan berbagai penyakit. Diperlukan usaha preventif untuk menanggulangimya mengingat bahwa wabah ini tidak bisa dianggap sebagai pandemi biasa. Untuk itu mikroorganisme ini perlu dimusnahkan atau dicegah penyebarannya, salah satu upaya pencegahan dengan mencuci tangan dengan sabun, bila tidak terdapat air dan sabun dapat dengan menggunakan hand sanitizer. Hand sanitizer merupakan bahan pembersih yang berupa cairan yang digunakan untuk membersihkan tangan dari debu, bakteri/virus tanpa memerlukan bilasan air. Tujuan dari pengabdian masyarakat ini adalah memperkecil terjadinya penularan Covid-19 dengan cara menggunakan hand sanitizer bagi Staf Pengajar dan Pegawai di SMK Negeri 5 Medan dan meningkatkan kesadaran untuk tetap selalu membawa dan menggunakan hand sanitizer dimanapun dan sesering mungkin. Adapun metode yang digunakan dalam pelaksanaan pengabdian masyarakat ini dengan sosialisasi pembuatan hand sanitizer pada staff pengajar dan pegawai di SMK Negeri 5 Medan. Mengingat keterbatasan hand sanitizer sekarang ini sehingga diperlukan sosialisasi pembuatan hand sanitizer dalam upaya pencegahan penularan covid-19. Pengetahuan dan pemahaman yang didapatkan oleh staff pengajar dan pegawai dari pembuatan hand sanitizer dapat diterapkan dirumah masing-masing sehingga dapat digunakan dikeluarga dan dibagikan kepada orang disekitar lingkungannya dalam upaya pencegahan penularan Covid-19.
EDUKASI COVID-19 PADA KELOMPOK TANI MBOK SRI UNGGUL KELURAHAN TUALANG KECAMATAN PERBAUNGAN KABUPATEN SERDANG BEDAGAI Dabukke, Hotromasari; Adiansyah*, Adiansyah; Sijabat, Salomo
Jurnal Abdimas Mutiara Vol. 2 No. 2 (2021): JURNAL ABDIMAS MUTIARA
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Aktivitas kehidupan manuasia terganggu dengan wabah Covid-19, data jumlah covid-19 di Indonesia mencapai 118 ribu orang meninggal dunia. Munculnya kasus virus ini membuat berbagai kota dan wilayah di indonesia harus melakakukan penyekatan/penutupan wilayah dan aktifitas kegiatan seperti Ekonomi, Pendidikan dan aktifitas pekerjaan lainya harus dialihkan dengan berbagai model seperti penggunaan aplikasi online dan daring. Edukasi covid-19 ini menjadi penting bagi masyarakat kelompok tani, karena kelompok tani tersebut terkena dampak terhadap hasil pertanian baik cara memasarkan dan cara memperoleh pupuk pertanian. Ide pengajuan pelaksanaan pengabdian masyarakat ini yang berjudul “Edukasi Covid-19 Pada Kelompok Tani Mbok Sri Unggul Kelurahan Tualang Kecamatan Perbaungan Kabupaten Serdang Bedagai” berbagai aktifitas kegiatan menjadi terganggu yang tentunya akan merugikan para petani yang tidak dapat beraktifitas normal di sawah maupun ladang. Materi sosialisasi adalah cara menggunakan masker non-medis secara benar dan berkesinambungan, sesering mungkin mencuci tangan dan penggunaan desinfektan pada tempat-tempat yang diduga terpapar covid atau yang sering dikunjungi orang ramai. Pelaksanaan kegiatan dimulai dari mempersiapkan masker yang akan di peragakan, bahan desinfektan dan materi yang akan disosialisasikan. Pada kegiatan sosialisasi kepada kelompok Tani Mbok Sri Unggul dilakukan juga acara pemberian masker kepada kelompok tani, kegiatan tersebut dihadiri sebanyak 22 orang peserta. Dari kegiatan tersebut terlihat peserta sangat antusias dan berperan aktif dalam kegiatan tersebut. Edukasi ini diharapkan mampu memberikan pencerahan kepada masyarakat agar dalam menghadapi pandemi ini mampu menjaga kesehatan dengan cara mengikuti protokol kesehatan.
PEMELIHARAAN PERALATAN KESEHATATAN TENSIMETER, STETOSKOP DAN STERILISATOR Dabukke, Hotromasari; Adiansyah, Adiansyah; Sijabat, Salomo
Jurnal Abdimas Mutiara Vol. 3 No. 1 (2022): JURNAL ABDIMAS MUTIARA (In Press)
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Peralatan kesehatan sangat banyak digunakan untuk pelayanan kesehatan, oleh karena itu pemeliharaan peralatan kesehatan wajib dilakukan untuk menghindari kesalahan hasil diagnosa. Pemeliharaan peralatan kesehatan adalah suatu upaya yang dilakukan agar peralatan medis selalu dalam kondisi layak pakai, dapat difungsikan dengan baik dan menjamin usia pakai lebih lama. Pemeliharaan peralatan kesehatan di lakukan di Klinik Nusantara Sehat. Pada klinik tersebut terdapat beberapa alat medis yaitu tensimeter analog, tensimeter digital, stetoskop dan sterilsator. Tujuan dari kegiatan ini yaitu untuk melakukan pengecekan pada peralatan tersebut seperti untuk mengetahui hasil akurasi dari alat, untuk melakukan pemeliharaan pada setiap bagian alat dan untuk melakukan perbaikan. Pemeliharaan peralatan kesehatan dibagi dua yaitu pemeliharaan terencana, pemeliharaan preventif dan pemeliharaan tidak terencana (korektif) dimana alat tersebut tidak dapat difungsikan. Tensimeter berfungsi merupakan alat yang digunakan untuk mengukur tekanan darah. Stetoskop berfungsi untuk mendengarkan suara organ di dalam tubuh, seperti denyut jantung, nadi, organ pencernaan, dan paru-paru dan Sterilisator berfungsi untuk mensterilkan bakteri, kuman atau mikroba. Setelah dilakukan pengecekan pada alat tensimeter tersebut alat dalam kondisi baik dan layak digunakan. Pengecekan pada alat stetoskop terdapat sumbatan pada filter dan sudah dibersihkan dan dalam kondisi baik. Alat sterlisator dalam kondisi baik setelah dilakukan pemeliharaan dan pengecekan pada heater dan kabel catu daya. Kegiatan ini berlangsung dengan baik dan melakukan pelatihan tentang perbaikan sederhana kepada user untuk melakukan pemeliharaan rutin pada alat tersebut.
SOSIALISASI DAN TRAINING SISTEM PEMELIHARAAN INFANT WARMER DI LABORATORIUM TERPADU Sijabat, Salomo; Dabukke, Hotromasari; Priyulida, Fitria
Jurnal Abdimas Mutiara Vol. 2 No. 2 (2021): JURNAL ABDIMAS MUTIARA
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Alat kesehatan adalah alat yang selalu dalam kondisi siap pakai. serta dapat difungsikan dengan baik. Hal ini menuntut kita untuk melakukan pengabdian kepada masyarakat di Rumah Sakit Advent untuk dapat mengelola dan memelihara peralatan medis seefektif dan seefisien mungkin. Jika fungsi pemeliharaan ini berjalan dengan baik, maka mutu dari peralatan medis yang digunakan akan baik pula. Pengabdian masyarakat ini bertujuan untuk mengetahui sistem pemeliharaan dan perawatan alat Infant warmer, mengetahui apa itu infant warmer,serta untuk mengetahui prinsip kerja Hasil dari kegiatan pengabdian telah berjalan dengan baik dan permasalahan yang terjadi sudah dapat diatasi. Pemeliharaan Infant Warmer harus rutin dan terjadwal untuk mencegah kerusakan sehingga usia pemakaian alat lama.