Amrul Amrul
Politeknik Negeri Semarang Jl. Prof. H. Sudarto,S.H. Tembalang, Semarang

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Rancang Bangun Alat Uji Komposisi Massa Pada Logam Paduan Berdasarkan Prinsip Gaya Angkat Fluida Slamet, Agus; Amrul, Amrul
J@ti Undip : Jurnal Teknik Industri Volume 2, No.1, Januari 2007
Publisher : Departemen Teknik Industri, Fakultas Teknik, Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (282.804 KB) | DOI: 10.12777/jati.2.1.37-45

Abstract

 Spectro Analyser merupakan alat uji komposisi yang sangat presisi dan harganya sangat mahal, maka diperlukan alat uji komposisi yang lebih sederhana dan murah tapi dapat berfungsi sebagai alat uji komposisi logam paduan yang terdiri dua unsur saja.                 Prinsip kerja dari rancang bangun Alat Uji Komposisi Massa ini adalah berdasarkan benda terbenam atau terapung pada permukaan fluida cair maka gaya yang bekerja pada benda tersebut terjadi karena tekanan fluida cair atau disebut sebagai gaya angkat (bouyancy.),                 Pengujian ini akan mendapatkan data dari alat uji adalah volume air yang dipindahkan atau volume bahan uji dan massa bahan uji saat di dalam fluida sebagai representasi dari resultan gaya..                 Metode penelitian yang dilakukan dimulai dari perancangan dan pembuatan alat ,kemudian dilanjutkan dengan pengujian, pengambilan data dengan cara mencelupkan bahan uji ke dalam fluida pada gelas ukur. Bahan uji yang digunakan mengandung dua unsur yaitu alumunium (Al) dan zink (Zn) dengan komposisi massa Bahan uji A :76,35% Al ;23,65% Zn, bahan uji B : 73,42% Al ;26,58% Zn dan bahan uji C: 83,38% Al ; 16,62% Zn. Dari hasil pengukuran dihitung ketidakpastian hasil pengukuran dari alat uji.                 Hasil pengujian dan data yang diperoleh dapat diketahui bahwa Alat uji komposisi massa dapat berfungsi untuk mengukur logam dengan paduan dua unsur dengan luaran massa bahan uji sebelum maupun saat di dalam fluida (air) dan volume air yang dipindahkan atau volume bahan uji. Dari ketiga bahan uji menghasilkan perbedaan nilai komposisi massa dibandingkan dengan nilai yang sudah ditentukan. Nilai perbedaan untuk bahan uji A,B dan C berturut-turut 3.31%, 5,10% dan 4,96%, sedangkan alat uji ini mempunyai ketidakpastian hasil pengukurannya sebesar 3,33%. Kata kunci : komposisi, massa,volume     The Spectro Analyzer is a very accurate and expensive test device, therefore it needs a more simple and cheaper composition test device which able to function as an alloy composition test device that only consist of  two elements. The principal work of this engineering of Mass Composition Test device is based to the sinking or floating object on the liquid fluid’s surface, therefore the force acting on it due to liquid pressure is termed buoyancy. From this test, the data that would be appeared in the device is the water volume that is transferred or the volume or the mass of the test material inside the fluid as a representation of resultant force. The research method begins from designing and device making, then followed by the test and data taking by immersed in the test material to the fluid in the maat glass. The test material consists of two elements, they are Aluminium (Al) and Zinc (Zn) with mass composition of Test Material A : 76,35% Al ;23,65% Zn, Test Material B: 73,42% Al ;26,58% Zn, and Test Material C: 83,38% Al ; 16,62% Zn. From the result of the calculation, it is estimate the uncertainty of the calculation result of the test device.   From the test result and obtained data, it is known that Mass Composition Test device is able to measure metal with two mixture elements with the test material’s outcome of mass before or when in the fluid and the water volume that is transferred or the test material’s volume. From the third test materials result the different of mass composition value compares with the specified value, the different value for test materials A, B, and C are 3.31%, 5,10% and 4,96%, this test device has an uncertainty result in measurement result about 3,33%. Key words : composition,mass,volume.                                 
Pengaruh Jarak antar Pipa Absorber terhadap Unjuk Kerja Kolektor Surya PV/T Pelat Datar Menggunakan Metode CFD Amrizal, Amrizal; Amrul, Amrul; Irsyad, Muhammad; Salsabillah, Angelia E.
Jurnal Rekayasa Mesin Vol 17, No 3 (2022): Volume 17, Nomor 3, Desember 2022
Publisher : Mechanical Engineering Department - Semarang State Polytechnic

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32497/jrm.v17i3.3628

Abstract

Karakteristik dari kolektor PV mengindikasikan bahwa kenaikan suhu operasi dapat menurunkan efisiensi listrik. Dengan demikian penggunaan kolektor jenis PV/T perlu diimplementasikan untuk mengatasi permasalahan ini.  Tujuan dari penelitian ini adalah untuk mengetahui unjuk kerja dari kolektor jenis hybrid Photovoltaic/Thermal (PV/T) baik secara termal maupun pressure drop berdasarkan variasi jarak antar pipa dari 43,5 mm hingga 170 mm. Parameter pengujian yang diteliti adalah temperatur keluar (Tout)  fluida kerja, temperatur permukaan kolektor dan pressure drop aliran yang terjadi. Intensitas radiasi yang digunakan adalah sebesar 960,9 W/m2 dengan laju aliran massa 0,01 kg/s. Penelitian ini dilakukan melalui metode simulasi CFD.  Lebih lanjut, hasil pengembangan simulasi menunjukkan bahwa perubahan  jarak antar pipa hanya mampu menurunkan temperatur fluida keluar kolektor maksimum 1 oC, sebaliknya kenaikan tekanan fluida keluar (pressure drop) hampir tiga kali lipat.  Sementara itu kolektor dengan jarak antar pipa 43,5 mm memiliki temperatur permukaan lebih rendah dan distribusi temperatur permukaan lebih merata dibandingkan dengan dua kolektor lainnya.