Economic dispatch by optimization techniques Rana Ali Abttan; Adnan Hasan Tawafan; Samar Jaafar Ismael
International Journal of Electrical and Computer Engineering (IJECE) Vol 12, No 3: June 2022
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v12i3.pp2228-2241

Abstract

The current paper offers the solution strategy for the economic dispatch problem in electric power system implementing ant lion optimization algorithm (ALOA) and bat algorithm (BA) techniques. In the power network, the economic dispatch (ED) is a short-term calculation of the optimum performance of several electricity generations or a plan of outputs of all usable power generation units from the energy produced to fulfill the necessary demand, although equivalent and unequal specifications need to be achieved at minimal fuel and carbon pollution costs. In this paper, two recent meta-heuristic approaches are introduced, the BA and ALOA. A rigorous stochastically developmental computing strategy focused on the action and intellect of ant lions is an ALOA. The ALOA imitates ant lions' hunting process. The introduction of a numerical description of its biological actions for the solution of ED in the power framework. These algorithms are applied to two systems: a small scale three generator system and a large scale six generator. Results show were compared on the metrics of convergence rate, cost, and average run time that the ALOA and BA are suitable for economic dispatch studies which is clear in the comparison set with other algorithms. Both of these algorithms are tested on IEEE-30 bus reliability test system.
Experimental installation of wireless power transfer system based on the series resonance technology Sarab Al-Chlaihawi; Adnan Hasan Tawafan; Fatima Kadhem Abd
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 11, No 4: December 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v11.i4.pp1693-1700

Abstract

In this work, we aim to install a wireless power transfer (WPT) system experimentally. Series resonance technology was used to achieve zero-voltage switching (ZVS). We investigated the impact of the primary and secondary resonance frequencies (fp and fd), and inverter frequency switching (fch) on the efficiency (β) and maximum transfer power in a WPT system based on the inductive wireless power transfer (IWPT) technology. An ultrasonic device was utilized as a generator to excite the coil at the primary side. The experimental outcomes showed that there is an optimum unlike fp and fd can be got to match fch. It was found also that there is a trade-off between the power supplied to the load (PRL) and DC-DC efficiency (β). At an air-gap of 5 cm, the obtained results are recorded as follows; the peak recorded system β is 62% that was obtained at fp=19 kHz, fd=fch=24 kHz that is corresponding to 101.88W of PRL; whereas the highest PRL resulted i.e. 244W when fp=19 kHz, fd =24 kHz, fch=21 kHz at 61% of β; in such case, the maximum β* PRL multiplication was achieved i.e. 149. Moreover, the coils’ misalignment was studied. The outcomes showed that the lateral misalignment has worst effect on the PRL and β than the air-gap. The experimental results were validated with simulation ones.
Optimization of detection of single line to ground fault by controlling peterson coil through ANFIS Feryal Ibrahim Jabbar; Dur Muhammad Soomro; Adnan Hasan Tawafan; Mohd Noor bin Abdullah; Nur Hanis binti Mohammad Radzi; Mazhar Hussain Baloch
IAES International Journal of Artificial Intelligence (IJ-AI) Vol 9, No 3: September 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1199.318 KB) | DOI: 10.11591/ijai.v9.i3.pp409-416

Abstract

The most common fault in the distribution network is the single line to ground fault (SLGF). With earthling in the distribution network, it causes electrical arc as well as a high voltage in the faulted phase compared to other two healthy phases. It increases the danger of separation and isolation in the power network. One of the classical technique to control the arc is through Peterson Coil (PC), which detects and turns off/reduces the electrical arc making the network safer, increasing its reliability and device's safety. To control the PC, some of the techniques used in this research area are PID, FL, NN etc. This paper presents Adaptive Neural-Fuzzy Inference System (ANFIS) technique to controlling the PC. It gives the best results by detecting the fault, reducing the electrical arc and minimizing the fault current to the rated current in a very short time. Moreover, this research focuses on suppressing fault current by looking at its higher and lower peaks. Also, it calculates the opposing inductance to compensate the capacitance caused. It will save thousands of tons of copper costs. This research was conducted using MATLAB. For the validity of the proposed technique results, PID control technique was used.