Current and Voltage Imbalances at BPTIK Universitas PGRI Semarang Margono Margono; Muhammad Amiruddin; Irna Farikhah
Advance Sustainable Science, Engineering and Technology (ASSET) Vol 3, No 1 (2021)
Publisher : Universitas PGRI Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26877/asset.v3i1.8385

Abstract

Energy conservation is an effort to increase energy efficiency. This research conducted an energy audit in the BPTIK (Badan Pengembangan Teknologi Informasi dan Komunikasi) department room at the Universitas PGRI Semarang, observing the value of electrical parameters, especially unbalanced voltage and current that have the potential to cause neutral currents. In this study the calculated unbalanced voltage value is 0.64% and unbalanced current is 20.25%. From the current development, the neutral current produces an average of 1.72 Amperes. From the value of the neutral current can be calculated the energy lost in the conductor neutral wire per day is about 0.01% of energy consumption by the load per day
SISTEM KENDALI PERALATAN ON/OFF VIA WEB Muhammad Amiruddin; Imadudin Harjanto; Rio Seto Wardhana
Prosiding SNST Fakultas Teknik Vol 1, No 1 (2014): PROSIDING SEMINAR NASIONAL SAINS DAN TEKNOLOGI 5 2014
Publisher : Prosiding SNST Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Instrumentasi berbasis web adalah suatu sistem yang digunakan untuk memantau dan mengendalikan kondisi alam dan dapat dilakukan secara remote melalui media jaringan komputer. Pemantauan dapat meningkatkan efisiensi dan dapat mendukung fungsi pemeliharaan yang selalu dibutuhkan untuk menurunkan biaya. Dalam penelitian ini, dibangun perangkat keras berbasis IP dengan protokol HTTP dengan format data XML menggunakan modul Wiznet W5100 sebagai modul Ethernet yang dikendalikan oleh mikrokontroler ATMega32 dengan tatap muka SPI. Sebuah perangkat keras mempunyai 8 kanal relay yang digunakan untuk mengendalikan beban secara on/off.  Uji coba dan evaluasi hasil penelitian ini dilakukan dengan pengujian 3 buah perangkat keras dan 1 buah web server yang membentuk sebuah jaringan. Sebagai pusat kendali dan pemantauan, sebuah PC difungsikan sebagai web server  yang dibangun dengan platform PHP dan terhubung dengan basis data PostgreSQL 9.2. Pengujian sistem dilakukan dengan cara pembacaan status dan pengaturan relay dengan iterasi sebanyak 4008 kali, menghasilkan prosentase keberhasilan pembacaan status relay adalah sebesar 97%, prosentase keberhasilan pengaturan relay adalah sebesar 99,65%, dan waktu respon sistem sebesar 0,23s. Kata kunci: mikrokontroler, Wiznet W5100, instrumentasi berbasis web, kendali on/off
RANCANG BANGUN COOLER BOX TERMOELEKTRIK DENGAN AIR STERILIZER SEBAGAI TEMPAT PENGIRIMAN AIR SUSU IBU (ASI) Gostsa Khusnun Naufal; Muhammad Amiruddin
Jurnal Rekayasa Mesin Vol 14, No 3 (2019): Volume 14, Nomor 3, Desember 2019
Publisher : Jurusan Teknik Mesin - Politeknik Negeri Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (453.563 KB) | DOI: 10.32497/jrm.v14i3.1637

Abstract

Tren yang berkembang saat ini adalah asi ekslusif yang diberikan kepada bayi sampai dengan bayi tersebut mempunyai usia yang cukup. Hal ini tentunya tidak terlalu bermasalah pada ibu rumah tangga yang sebagian besar waktunya berada di rumah, sehingga dapat menyusi bayi tersebut tanpa gangguan. Tetapi hal ini berbeda dengan wanita karir yang memiliki bayi dan ingin memberikan asi eksklusif, jarak yang jauh antara rumah dan tempat kerja serta keterbatasan waktu menjadi faktor penghalang yang membuat asi eksklusif menjadi sangat sulit diberikan oleh wanita karir kepada anaknya. Cooler box dapat menjaga agar suhu asi tetap dalam kondisi dingin mencegah kerusakan kandungan asi. Didalam cooler box dimasukkan ice gel yang membuat suhu tetap dingin. Ice gel tersebut dapat menjaga suhu tetap dingin selama 3-4 jam. Permasalahan lain adalah kehigienisan dari cooler box serta wadah penyimpan dari asi. Tidak jarang cooler box menjadi sumber bakteri yang dapat menyebar ke asi yang terdapat pada cooler box, hal ini bisa diakibatkan kelembapan ataupun dari tangan yang tidak steril. Hal ini dikarenakan dalam proses pumping serta pemindahan ke dalam cooler box masih menggunakan cara manual dengan tangan. Peneliti akan merancang bangun cooler box dengan menggunakan termoelektrik sebagai pendingin dari cooler box serta memiliki air sterilizer, yang berguna menurunkan jumlah bakteri dengan menggunakan uv light. Kadar bakteri yang rendah akan membuat cooler box menjadi lebih higienis sebagai tempat penyimpanan asi ketika akan dikirimkan.
DC TO DC CONVERTER UNTUK SISTEM CHARGER ACCUMULATOR OTOMATIS ENERGI SOLAR CELL muhammad amiruddin
Jurnal Ilmiah Teknosains Vol 4, No 1 (2018): JiTek
Publisher : Universitas PGRI Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (127.44 KB) | DOI: 10.26877/jitek.v4i1.2304

Abstract

Solar cell adalah salah satu penghasil energi terbaharukan. Untuk memberikan energi yang stabil, sistem memerlukan sebuah accumulator. Untuk mengoptimalkan umur  dan efisiensi accumulator, maka dibutuhkan metode pengisian accumulator yang baik. Tegangan keluaran solar cell berubah-ubah sesuai dengan kondisi lingkungan khusunya sinar matahari, maka dalam penelitian ini dirancang sebuah sistem DC to DC converter yang menggabungkan kerja full bridge dan boost converter yang mampu menaikkan dan menurunkan tegangan masukan agar menghasilkan tegangan yang stabil sesuai dengan kebutuhan tegangan pengisian accumulator 13.8 sampai dengan 14.7 Volt. Pada hasil pengujian dengan pemberian beban, tercatat bahwa efisiensi maksimal sebesar 86.7% pada pengujian  dengan beban 4.6 ohm, efisiensi maksimal sebesar  87.6% pada pengujian dengan beban 7.1 ohm, efisiensi maksimal sebesar 95.3% pada pengujian dengan beban 14 ohm.
Numerical Study on the Effect of Mean Pressure and Loop's Radius to the Onset Temperature and Efficiency of Traveling Wave Termoacustic Engine Endang Dian Rokhmawati; Irna Farikhah; Ummi Kaltsum; Harto Nuroso; Aan Burhanudin; Yuris Setyoadi; Muhammad Amiruddin; Irfan Abd Rahim
Automotive Experiences Vol 3 No 3 (2020)
Publisher : Automotive Laboratory of Universitas Muhammadiyah Magelang in collaboration with Association of Indonesian Vocational Educators (AIVE)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1038.257 KB) | DOI: 10.31603/ae.v3i3.3881

Abstract

The thermoacoustic engine can be a device to convert waste heat energy in the engine car become useful energy such as for charging battery in car or Air conditioner of the car. This work can be done by experimentally and numerically. There are some parameters that have an impact on the performance of the engine. They are geometry of the engines, working fluid, and mean pressure. The performance of the engine depends on the efficiency and the heating temperature. In the car, waste heat energy is not high enough. Therefore, we need to utilize the low heating temperature to be converted into useful energy. This study contributes to numerically the effect of mean pressure and loop’s radius of the regenerator on the onset temperature and the efficiency of traveling wave thermoacoustic engines. The application that is used to solve numerical problems is fortran95. There are two codings that are used in fortran95. They are stability limits and efficiency codes. The lowest onset temperature that achieved is 153˚C with efficiency up to 38.1% that can be reached when the mean pressure is 4.0 MPa and the loop's radius is 5 cm. This result indicated that we can use low heating temperatures from waste heat of engine car to turn on electronics equipment inside the car.
Power Losses Caused by Load Imbalance in the Central Building of PGRI Semarang University Muhammad Zaenal Arifin; Muhammad Amiruddin; Margono Margono
Advance Sustainable Science Engineering and Technology Vol 5, No 1 (2023): November-April
Publisher : Universitas PGRI Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26877/asset.v5i1.13854

Abstract

The use of energy is basically very much needed in everyday life. Energy that is widely used is electrical energy, because electricity is one of the important factors in human life. Some electrical energy producers, in the country use fossil fuel sources such as coal and petroleum, and fossil energy is not renewable. Therefore, the government through the Regulation of the Minister of Energy and Mineral Resources number 14 of 2012 regulates energy management to control energy consumption in order to achieve effective and efficient energy utilization. PGRI Semarang University [L1] as an academic institution uses a lot of non-linear loads for administrative, teaching, laboratory and other supporting activities. Based on the analysis of data obtained at the Center Building of PGRI Semarang University experiencing an imbalance, the condition is not in accordance with the standards and risks increasing power losses. Seeing these conditions, recommendations were obtained that can be implemented at the Center Building of PGRI Semarang University, namely, balancing the load of phases R, S, T to reduce current imbalances. From the load imbalance, there were power losses on the neutral wire of 889,363 kW and power usage for one day in the R, S, T phases of 15,497,991 kW  
ANALISIS PERBANDINGAN EFISIENSI PEMAKAIAN ENERGI LISTRIK ANTARA PLN DAN GENSET DI POLLUX MALL PARAGON SEMARANG Aldo Dwiki Mahendra; Margono Margono; Muhammad Amiruddin
TRANSISTOR Elektro dan Informatika Vol 5, No 1 (2023)
Publisher : Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/ei.5.1.%p

Abstract

Masalah dengan melambungnya harga minyak bumi dan semakin menipisnyacadangan minyak bumi kita diharuskan untuk menghemat pemakaian energi yang dihasilkan oleh pemakaian minyak bumi. Apalagi negara kita merupakan Negara pengimpor minyak. Sehingga semakin bamyak pemakaian minyak bumi didalam negri maka semakin besar pula jumlah minyak yang harus diimpor dan secara otomatis akan menguras keuangan Negara. Antara lain pemakaian minyak bumi didalam negri digunakan untuk : pembangkit listrik, industri, kendaraan, memasak, dan masih banyak lainnya. Penelitian ini bertujuan untuk mengetahui perbandingan efisiensi pemakaian energi listrik antara PLN (Grid) dan genset dengan melihat Net Present Cost, Total Annual Cost, Cost of Energy, dan Break Event Point dengan dibantu software HOMER PRO 3.14.2. Dimana diperoleh Netto sekarang biaya penggunaan energi listrik sumber PLN sebesar Rp. 355.105.400.000, Total biaya tahunan sebesar Rp.27.468.960.000, total energi yang dipakai sebesar 23.493.590 kWh, serta biaya energi Rp. 1.169 /kWh. Dan untuk penggunaan sumber energi listrik genset diperoleh Net present cost sebesar Rp. 1.380.000.000.000, Total biaya tahunan sebesar Rp. 105.343.700.000, total energi yang dipakai sebesar 23.493.590 kWh, serta biaya energi Rp. 4.529/kWh. Yang berarti untuk penggunaan sumber energi genset di Paragon Mall Semarang, saat ini belum memungkinkan untuk mengalihkan secara menyeluruh sumber dari PLN dan hanya digunakan untuk cadangan saja jika PLN terjadi gangguan. 105.343.700.000, total energi yang dipakai sebesar 23.493.590 kWh, serta biaya energi Rp. 4.529/kWh. Yang berarti untuk penggunaan sumber energi genset di Paragon Mall Semarang, saat ini belum memungkinkan untuk mengalihkan secara menyeluruh sumber dari PLN dan hanya digunakan untuk cadangan saja jika PLN terjadi gangguan. 105.343.700.000, total energi yang dipakai sebesar 23.493.590 kWh, serta biaya energi Rp. 4.529/kWh. Yang berarti untuk penggunaan sumber energi genset di Paragon Mall Semarang, saat ini belum memungkinkan untuk mengalihkan secara menyeluruh sumber dari PLN dan hanya digunakan untuk cadangan saja jika PLN terjadi gangguan. Kata Kunci : Biaya Energi, Genset , HOMER PRO, Net Present Cost , PLN ( Grid )
Pendampingan Pembenahan Instalasi Sistem CCTV untuk Masjid Baitul Rohmah Pudak Payung Semarang Muhammad Amiruddin; Imadudin Harjanto; Bambang Hadi Kunaryo; Margono Margono
PaKMas: Jurnal Pengabdian Kepada Masyarakat Vol 3 No 1 (2023): Mei 2023
Publisher : Yayasan Pendidikan Penelitian Pengabdian Algero

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54259/pakmas.v3i1.1653

Abstract

Apart from being a place of worship, the mosque has a function to improve community relations in the environment around the mosque in particular. In order to improve community relations, it is necessary to hold several activities involving the community under the auspices of the mosque. In order for community activities to take place, the mosque is equipped with several assets such as electronic devices, sound systems, air conditioning, infaq contacts/charity boxes and some other supporting furniture. So mosque assets need to be maintained in the security aspect. To support the security aspects of the mosque's environment, in this service there will be mentoring and training on the CCTV (Close Circuit Television) system. This service activity is carried out by technicians, mosque congregation and accompanied by a service team, including; needs assessment, field survey, network design and layout, preparation of budget plans and device requirements, device installation and device firmware settings. After being agreed by the team, this service installed 5 camera points to monitor 4 areas, parking area, yard, congregation area and priest area. From the results of this activity, that the installation of cameras at 5 points in accordance with the planned survey results and needs assessment can provide comprehensive monitoring of environmental conditions outside and inside the mosque, so that it can better guarantee security in the mosque and its surroundings.