Two Mode DPM Equipped with an Automatic Leak Test Using MPX5050GP and MPXV4115VC6U Sensors Fita Florensa Rooswita; Triana Rahmawati; Syaifudin Syaifudin
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 1 (2021): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i1.1

Abstract

The calibration process aims to guarantee measurement results in accordance with established standards. One of the tools used for pressure calibration is the Digital Presure Meter, which is the function of this tool to measure pressure on the Sphygmomanometer and Suction Pump or other tools that use pressure parameters for measurement. This module uses the Arduino system as a control and processing of analog data into digital data in order to condition the output of the MPX5050GP sensor for positive pressure and MPXV4115VC6U sensor for vacum pressure, this module uses a 4x20 LCD character display and there is a selection of mmHg and Kpa units with fluctuating resolution 0.25. Also in this module there is also an automatic leak test feature for the Sphygmomanometer, the measurement results obtained an average error of 7.3 mmHg for sphymomanometer measurements, and for suction pumps less than 1.5 Kpa. From these results it was concluded that this module can be used for the measurement of tools that use positive pressure and negative pressure.
Utilization of Power Setting in Monopolar Electrosurgery Unit With Additional Blend Modes Muhammad Roni Setiawan; Tri Bowo Indrato; Triana Rahmawati
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 3 (2020): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i3.4

Abstract

Electrosurgery unit has the purpose of damaging certain body tissues by heating the tissue. In this study there are several modes and also power selection. The contribution of this research is to design the power management and also the addition of several modes for the surgical process. Electrosurgery Unit involves the use of IC CMOS 4069 as a frequency generator. The frequency output is set at 250 KHz and then passed on to the pulse regulator circuit and controlled by using Arduino and then forwarded to the inverter circuit which functions to increase the voltage and output in the form of power. Modules are calibrated using ESU Analyzer. This module is equipped with a selection of LOW, MEDIUM, and HIGH power. And also there are some additional modes including Blend 1 and Blend 2. After the measurement is carried out, the voltage values ​​obtained at the setting of low, medium high, on the inverter input with a value on Blend 1 mode low 80 V with an error of 0.84%, Medium 90 V with error 0.84%, High 104 V with an error of 0.81%, in Blend 2 mode low 84 V with an error of 0.83%, Medium 86 V with a error of 0.85%, High 105 V with an error of 0.81%, the Cutting mode is low 162 V with an error of 2.88%, medium 172 V with an error of 3.03%, High 192 V with an error of 2.86%. The measurement shows an error of less than 1% for Blend 1 and Blend 2 modes while cutting is less than 3%. The results of this study can be implemented in order to minimize errors due to lack of power settings and mode selection during surgery.
Utilization of Power Setting in Mono-polar Electrosurgery Unit With Additional Blend Modes Muhammad Roni Setiawan; Tri Bowo Indrato; Triana Rahmawati; Bedjo Utomo
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 2 (2020): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.7

Abstract

Electrosurgery unit has the purpose of damaging certain body tissues by heating the tissue. In this study there are several modes and also power selection. The contribution of this research is to design the power management and also the addition of several modes for the surgical process. Electrosurgery Unit involves the use of IC CMOS 4069 as a frequency generator. The frequency output is set at 250 KHz and then passed on to the pulse regulator circuit and controlled by using Arduino and then forwarded to the inverter circuit which functions to increase the voltage and output in the form of power. Modules are calibrated using ESU Analyzer. This module is equipped with a selection of LOW, MEDIUM, and HIGH power. And also there are some additional modes including Blend 1 and Blend 2. After the measurement is carried out, the voltage values ​​obtained at the setting of low, medium high, on the inverter input with a value on Blend 1 mode low 80 V with an error of 0.84%, Medium 90 V with error 0.84%, High 104 V with an error of 0.81%, in Blend 2 mode low 84 V with an error of 0.83%, Medium 86 V with a error of 0.85%, High 105 V with an error of 0.81%, the Cutting mode is low 162 V with an error of 2.88%, medium 172 V with an error of 3.03%, High 192 V with an error of 2.86%. The measurement shows an error of less than 1% for Blend 1 and Blend 2 modes while cutting is less than 3%. The results of this study can be implemented in order to minimize errors due to lack of power settings and mode selection during surgery.
A Low Cost Negative Pressure Wound Therapy Based on Arduino Fikri Fahriansyah Pramono; Sari Luthfiyah; Triana Rahmawati; Nur Hasanah Ahniar
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 2 (2020): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.2

Abstract

Instant life patterns and eating patterns and inappropriate exercise schedules are thought to be one of the causes of the increasing number of diabetes mellitus. Complications that can be caused by this disease are in the form of excessive susceptibility to infection, so that it develops into diabetic ulcers and can lead to amputations in these parts of the body. The purpose of this study is to design a tool used to treat diabetic ulcers. The contribution of this study is that the system can help remove fluid from the wound with controlled suction pressure so that it can facilitate the healing process faster. This Negative Pressure Wound Therapy (NPWT) tool works based on negative pressure from the vacuum motor by utilizing MPXV4115VC6U and MPXV5050VC6T1 pressure sensors at a pressure limit of 0 to -350 mmHg. Using an Arduino microcontroller for data processing, it will then be displayed on the 2x16 LCD. The MPX4115VC6U sensor produces a pressure of -55.97 mmHg when setting -50 mmHg and the resulting output is 3.32 volts, while the MPXV5050VC6T1 sensor produces a pressure of 51.18 mmHg at a setting of 50 mmHg and the resulting output is 3.18 volts, from the above data it can be seen if the MPX5050VC6TI sensor has a smaller error given