Design of Phototherapy Radiometer with a Measurement Stability Improvement Ayu Dini Megantari; Syaifudin Syaifudin; Endang Dian Setioningsih
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 1 (2021): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i1.5

Abstract

The amount of radiation given from the phototherapy lamp (Blue Light) who not right for neonates with hyperbilirubin is feared to cause the bilirubin levels in not decrease accordance with the calculated dose. The purpose of this study is to make a Blue Light calibration device with a stable measurement. The contribution of this research is by determine a sensor who able to measure the irradiation value more accurately between TCS3200 and AS7262 sensor. TCS3200 sensor measures the wavelengths of 470nm, 524nm and 640nm and AS7262 sensor can measure wavelengths of 430-670nm. The results of both sensors are stored in the Electrically Erasable Programmable Read-Only Memory, with the amount of data and the length of measurement can be adjusted according to user needs. Measurement the irradiation value of two sensors is done simultaneously using 3 Watt Light Emitting Diode lamp as a Blue Light simulation where the lamp is placed directly above the sensor and distance of the lamp to the sensor is 10cm, 20cm, 30cm, and 40cm. The average uncertainty value with TCS3200 sensor is 14.65 and the average uncertainty value with AS7262 sensor is 2.17. Type A uncertainty value is based on results of repeated measurements that show how close the measurement results are to the actual value (stable measurement results). The results showed that the average uncertainty value on AS7262 sensor is relatively small, so its mean the measurement results of AS7262 sensor are stable. The author suggests using sensors who capable of reading the value of light radiation without conversion. The results of this study can be implemented to measure the intensity of the lamp and be used as a reference to determining the time of lamp replacement.
Improving the Effectiveness of Automatic Pure Tone Audiometer with Audiogram and Patient Diagnosis Aulia Rahmawati; I Dewa Gede Hari Wisana; Endang Dian Setioningsih; Sari Luthfiyah; Bedjo Utomo
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 3 (2020): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i3.2

Abstract

Conventional Audiometer testing using manual mode takes quite a long time for one patient, and the audiologist must accompany until the test is complete. The purpose of this research is to design a pure tone audiometer with an automatic mode using Arduino microcontrollers. Contributions from this research is a system of automatic running to improve health services. The Hughson Westlake method is used for automatic mode. The method is prepared in the Arduino software and uses the CD4066 digital switch to regulate the frequency and intensity given to the patient. As for the frequency generator using XR2206, the raised frequencies are 250, 500, 1000, 2000, 4000, 8000 Hz. Then the patient will press the interrupt button if listening to sound, and the result will be displayed to the Audiogram on Android. Patient diagnostic results can be seen when testing the entire frequency has been completed. At frequency 250 Hz obtained error value 0.13, at frequency 500 Hz obtained error value 4.37, at frequency 1000 Hz obtained error value 39.5, at the frequency of 2000 Hz obtained error value 24.67, at the frequency of 4000 Hz obtained error value 67.33. And at the frequency of 8000 Hz obtained error value 32.33. The results of this study showed that the highest error was 3.95% at 1000Hz frequency and the smallest error was 0.05% at 250Hz frequency. The results of this study can be implemented in conventional audiometer system to accelerate testing time to improve service and facilitate audiologist during hearing testing.