Performance Comparison of ECG Bio-Amplifier Between Single and Bi-Polar Supply Using Spectrum Analysis Based on Fast Fourier Transform Anita Miftahul Maghfiroh; Syevana Dita Musvika; Vugar Abdullayev
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.248

Abstract

Heart performance is one of the vital signs that cannot be ignored and must be monitored periodically. In this case, the measuring range of the human heart rate is between 60-100 BPM, in which the measurement unit is expressed as Beat per Minute (BPM). Therefore, it is very important to use Electrocardiograph equipment to tap the electrical signals of the heart with correct readings and minimal interference such as frequency of electric lines and noise. The purpose of this study was to compare the instrumentation amplifier using a single supply with a bi-polar supply in the ECG design to select the best instrumentation amplifier, which is expected to contribute to other researchers in choosing the right type of instrumentation amplifier that is efficient and qualified. In this case, the research was carried out by comparing two single supply instrumentation amplifiers using the AD623 IC and the bi-polar supply using the AD620 IC, continued by the use of Fast Fourier Transform (FFT) to determine the frequency spectrum of the ECG signal. The test results further showed that the use of single power instrumentation could reduce more noise compared to the Bi-Polar instrumentation amplifier by strengthening 60 dB Low pass filter circuit. Meanwhile, the FFT results in finding the frequency spectrum explained that the FFT results on the ECG signal provided information that the ECG signal had a frequency range between 0.05 Hz and 100 Hz. When the frequency is more than 100 Hz, the frequency started to be suppressed and when the frequency is less than 100 Hz, the frequency is passed. This research could be further used as a reference by other researchers to determine which type of instrumentation amplifier is better.
Analysis of Temperature Distribution in Blood Banks Through Storage of Measurement Results with IoT Monitoring in the Blood Donor Unit of PMI Surabaya Farisy Azis Satria Wardhana; Anita Miftahul Maghfiroh; Dyah Titisari; Sumber Sumber; Vugar Abdullayev
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 2 (2023): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.278

Abstract

Temperature or temperature is an indicator of the degree of heat of an object. Cold chain or cold chain is a supply chain system that considers the temperature level in the process. Cold chain to keep frozen or chilled products in an environment with a certain temperature during production, storage, transportation, processing and sales. This is intended to maintain product quality. The purpose of this study was to determine the temperature distribution in the Blood bank at UDD PMI Surabaya City which was used for storage of blood products. By using the ESP32 system and the DS18B20 temperature sensor which will then be monitored via IoT, it will make it easier for users to monitor. The results of these measurements will be stored in a micro SD card for analysis. The data is processed by Non-Parametric Test resulting in an interpretation that the temperature of each shelf is different due to the difference in the location of the sensor placement. The temperature difference is also influenced by the pattern of use and the process of heat transfer from the bottom to the top of the shelf. This research was considered successful with the result of the highest temperature distribution being 3°C and the lowest being 2°C. The location of these racks can be useful in determining day-to-day monitoring measuring points. This value has met the standard for storage of blood products, which is in the range of 2°C-6°C.