PERANCANGAN SEPARATOR UNTUK MEMISAHKAN FLUIDA PADAT DAN CAIR Sanda Sanda
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 4, No 8 (2007): November 2007
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2204.596 KB)

Abstract

ABSTRAK PERANCANGAN   SEPARATOR  UNTUK  MEMISAHKAN  FLUIDA  PADA T DAN  CAIR. Salah   satu   tahapan    dalam   proses   transesterifikasi    dalam   pembuatan    bioaditif   adalah pemisahan  bahan hasil produksi  berupa bioaditif sebagai produk  cair dan gliserin yang bersifat padat..  Untuk  mendukung  proses  tersebut  telah dirancang  "Separator"  (pemisah)  fluida padat dengan  metode penggerak  putar centrifugal  (centrifuge)  dengan  memanfaatkan  bilah pemutar yang mempunyai  sudut kemiringan  posisi bilah terhadap  spindel 45o dan kemiringan  bilah 10o. Putaran bilah digerakan  dengan motor pada kecepatan  putar yang bisa divariasi  antara 500 - 2900 rpm.  Hasil perhitungan  menunjukan  bahwa  kecepatan  maksimal  bilah1  =  26.56   m/detik dan kecepatan  maksimal    bilah 2 = 53.12 m/detik.  Gaya sentrifugal  yang terjadi di dalam fluida adalah 9.573,  74 -  19.147,48    .N,   Gaya tersebut  akan mampu  menekan  fluida di dalam bejana dan memisahkan  fluida padat dari fluida cair.       Berdasarkan  hasil pengujian  diperoleh jumlah fluida yang  keluar  dari  bibir  bejana  bersifat  proporsional,  yaitu  semakin  tinggi  putaran  motor semakin  banyak  fluida  yang  keluar. Pengujian   berdasarkan  sedimentasi  paksa  oleh putaran bilah  menunjukan   bahwa,   pada  putaran  rendah  diperlukan   waktu  yang  lama,  (n  500  rpm, diperoleh  waktu produksi  35 menit),   sedangkan   pada  putaran  tinggi  waktu produksi  menjadi lebih cepat (n 2900 rpm, waktu produksi  15 menit). kata kunci :  separator,  bioaditif, centrifugal.ABSTRACT A  DESIGN  OF  SEPARATOR  FOR  SEPARATING  LIQUID  AND  CRAMMING  FLUID. One of steps in transesterification  process in producing  bioaditive is separation  of product result material namely  bioaditive  as  liquid  product  and  gliserin  as  cramming  fluid.   To support  this process  has  be  designed  a  separator  cramming  by  centrifugal  force  that  uses  blade  driver having inclination  45o and blade slope  10o.The blade has been spun by an electric motor with the speed  in between  500 up to 2900 rpm.. The calculation  shows  that the blade 1   maximum speed is 26.56   m/s and and maximal speed blade 2 is 53.12 m/s.   The centrifugal  force in fluid was in between  9,573. 74 up to  19, 147.48 N.   The force  will be able to press  the fluid get out from the vessel  and separate  the liquid from cramming fluid.   Based on the testing results,  the amount of fluid get out from the vessel are proportionality,   increasing  the speed of the electric motor  will  increase  the  flow  out  of  the  fluid  from  the  vessel.   Other testing based  on  the sedimentation  force by the blades shows that the low speed requires longer time for production (n =  500 rpm requires 35 minutes) while at the high speed the time will be shorter (n = 2900 rpm requires  15 minutes for production). key words :  separator,  bioadditive,   centrifugal.
DESAIN SISTEM PENGGERAK SELING SUMBER ISOTOP IRIDIUM-192 PADA BRAKITERAPI KANKER SERVIK DOSIS SEDANG Ari Satmoko; Sanda Sanda; Tri Harjanto; Atang Susila
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 7, No 14 (2010): Nopember 2010
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1021.131 KB)

Abstract

DESAIN SISTEM PENGGERAK SELING SUMBER ISOTOP IRIDIUM-192 PADA BRAKITERAPI KANKER SERVIK DOSIS SEDANG. Kegiatan perekayasaan brakiterapi pada tahun 2010 bertujuan untuk menghasilkan desain rinci perangkat brakiterapi kanker servik dosis sedang dengan memanfaatkan sumber isotop Iridium-92 berdaya pancar antara 5 hingga 10 Curie. Sumber dibungkus dalam kapsul stainless steel SS-316 yang dirangkai dengan seling SS-316 berdiameter sekitar 1 mm dan panjang 1800 mm. Sebagai bagian dari kegiatan ini, desain awal sistem mekanik penggerak sumber isotop telah dikembangkan. Kegiatan telah berhasil menentukan spesifikasi teknis komponen-komponen utama sistem mekanik penggerak. Kegiatan diawali dengan mempelajari desain konsep, melakukan perhitungan dan menentukan spesifikasi teknis, serta menetapkan komponen utama. Dari berbagai evaluasi yang telah dilakukan, beberapa komponen telah diputuskan yaitu motor stepper PK264A1- SG10, bearing tipe jarum NKI-10/20, tabung spiral berdiameter 120 mm berbahan SS316-1/8", sabuk berbahan dasar karet dengan lebar 20 mm, serta drum besar berdiameter 100 mm berbahan aluminium. Tidak semua komponen dapat diidentifikasikan secara detil terutama komponen yang tidak ada di pasar dan harus dibuat sendiri. Dengan telah ditentukannya komponen-komponen utama tersebut, maka kegiatan lanjutan berupa desain rinci sistem mekanik penggerak seling sumber isotop dapat dilakukan. A MECHANICAL SYSTEM DESIGN OF THE IRIDIUM-192 ISOTOPE WIRE IN CERVICAL CANCER BRACHYTERAPHY WITH MEDIUM DOSE RATE. In 2010, brachytherapy engineering development activities have a purpose to establish a detailed design of the cervical cancer rachiteraphy with medium dose rate. The brachyteraphy will use an Iridium-92 source with the emiting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8" with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the marketplace and have to be created ourself Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. Keywords: brachyteraphy, wire, source, drive
PENYELESAIAN PROBLEM STRESS PADA PIPA DENGAN TEKNIK SPRING COLD DAN SPRING HANGER Sanda Sanda
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 5, No 9 (2008): Juni 2008
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2640.366 KB)

Abstract

ABSTRAK PENYELESAIAN  PROBLEM  STRESS PADA PIPA DENGAN  TEKNIK SPRING  COLD DAN SPRING HANGER.  Pengaruh suhu fluida yang mengalir di dalam pipa dari sebuah nozzle pompa ke nozzle tanki akan menyebabkan  pemuaian  atau pengkerutan.  Kondisi  tersebut akan menarik atau menekan  ke arah nozzle pompa  dan nozzle tanki. Akibat pergerakan  pipa  akan menimbulkan  displacement  dan gaya batik terhadap pipa tadi.  Oleh karena  itu harus dihitung harga Displacement,  Restraint dan Stress,  agar gaya yang timbul mampu ditahan dan diterima oleh pipa tanpa harus mengalami perpatahan  ataupun pecah sesuai dengan kekuatan material pipa. Berdasarkan perhitungan,  menggunakan program Caesar II.  dihasilkan displacement  Dy = -30,224  mm, Restraint  summary  Fy =  75,851  kg dan Stress   =  5.026,9   kg/cm2,   kemudian  dari data tersebut  dilakukan  pemotongan  sebesar  Dy dengan  metode  Spring  Cold,  lalu dilakukan running pada program  Caesar  II.  ,    ternyata  hasilnya  tidak jauh  berbeda  dengan  hasil running awal, yaitu Dy = -30,038  mm,  Restraint  Summary Fy = 75.562  kg dan stress =  5.006, 7 kg/cm . Hal tersebut diatas  masih menunjukkan  terjadinya  stress pada  instalasi pipa  karena  Restraint summary yang terjadi pada nozzle dan stress pada pipa sangat besar. Selanjutnya dicari solusi untuk menyelesaikan  masalah  stress tersebut dengan pertimbangan  bahwa pipa Æ 30" sangat rigid,  yaitu dengan cara menghilangkan      support     dan mengganti dengan spring hanger, lalu dirunning  dan dihasilkan  Dispalecement  45,588   mm,  Restraint  summary  Fy  =  -1.823   kg dan Stress  2.1178   kg/cm2    dengan   allowable  stress  2. 121, 1   kglcm2.     Melihat  hasil  perhitungan dengan  spring  hanger  ternyata  stress  yang  terjadi lebih kecil dari allowable  stress,  sehingga kondisi ini dinyatakan aman untuk diinstal. Kata kunci:  Cold Spring,  Caesar 11.4.,  Pipa ABSTRACT THE  FINISHING   PROBLEM   OF  STRESS  ON  PIPE   WITH  COLD   SPRING  AND HANGER  SPRING. The Fluid  temperature influence stream in piping  from pump  nozzle to tank nozzle will cause expansion  or contraction.  This condition  will pull or press  to the nozzle.  The consequences  of piping  displacement,  so will rise return force to piping.  Because  of that must be calculated   the displacement  using Caesar 11.4  program  so that force of rising  can support  by piping without fracture and break.  From calculation,    resulted displacement  Dy = -30,224  mm, Restraint summary Fy =  75,851  kg and Stress  =  5.026,9   kglcm2    and then It done to cut of Dy with Cold Spring method,  and so Running on Caesar 11,4 program,  resulted that It not different with the first data  namely   yaitu  Dy  =  -30,038   mm,  Restraint  Summary  Fy  =  75.562   kg and stress =  5.006, 7 kglcm2.   Because of data still stress on Piping Installation indicated  by value of Restraint summary and stress were hight.  And then It has taken solution by consideration   that pipe  of Æ 30"  very rigid,  namely  to lose  The support  and change  with the sring  hanger,  so program  of Caesar 11.4 has  run  and result  of support  displacement  is 45, 588 mm,   Restraint summary Fy = -1.823   kg dan Stress 2.1178  kg/cm2 with allowable stress 2.121,1 kglcm2.     It see result of calculate with spring hanger,  in fact The stress more little than allowable stress,  so that this condition is safety to install. Key words : Cold Spring,  Caesar 11,4,  Pipe.